FS Managed L2+ Gigabit Switches User Guide
Introduction
Thank you for choosing S3910 Series Stackable Managed Switches. This guide is
designed to
familiarize you with the layout of the switch and describes how to deploy the
switch in your network.
Accessories
S3910-24TF
S3910-24TS/S3910-48TS
NOTE: S3910 series switches have dust plugs delivered with them. Keep the
dust plugs
properly and use them to protect idle optical ports.
Hardware Overview
Front Panel Ports
S3910-24TF
Front Panel Button
Back Panels
Front Panel LEDs
Installation Requirements
Before you begin the installation, make sure that you have the followings:
- Phillips screwdriver.
- Standard-sized, 19″ wide rack with a minimum of 1U height available.
- Category 5e or higher RJ-45 Ethernet cables, ber optical cables and console cable for connecting network devices.
Site Environment:
-
Do not operate it in an area that exceeds an ambient temperature of 50°C.
-
The installation site must be well ventilated. Ensure that there is adequate airow around the
switch. -
The switch should be installed at least 1U (44.45mm) away from devices to its sides.
-
Be sure that the switch is level and stable to avoid any hazardous conditions.
-
Do not install the equipment in a dusty environment.
-
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
-
Ensure rack and working platforms are well earthed.
Mounting the Switch
Desk Mounting
- Attach four rubber pads to the bottom.
- Place the chassis on a desk.
Rack Mounting
- Secure the mounting brackets to the two sides of the switch with the supplied M4 screws.
2. Attach the switch to the rack using four M6 screws and cage nuts.
Wall Mounting
1. Attach the mounting brackets to the switch with the supplied M4 screws.
2. Use the expansion screws to securely attach the mounting brackets on the wall.
NOTE: Suitable for mounting on concrete or other non-combustible surface only.
Installing the Power Supply Module
S3910-48TS/S3910-24TS
- Take a new power module out of the package.
- Take the plane printed with power information as the top panel of the power module. Hold the handle of the power module with one hand, and hold the end of the power module with the other hand. Insert it into the chassis along the guide rail steadily and slowly until a click is heard, and make sure that it is in good contact with the power slot.
**NOTE:**
- S3910-24TF switch has one built-in power supply.
- Insert the power module steadily. Please pay attention to the direction of the power panel to avoid wrong insertion. If the position is not proper, press the plug of the power module and hold on to the module handle with one hand to pull it out slowly, then re-insert it.
Grounding the Switch
- Connect one end of the grounding cable to a proper earth ground, such as the rack in which the switch is mounted.
- Secure the grounding lug to the grounding point on the switch back panel with the washers and screws.
Connecting the Power
- Plug the AC power cord into the power port on the back of the switch.
- Connect the other end of the power cord to an AC power source.
WARNING: Do not install power cable while the power is on.
Connecting the RJ45 Ports
- Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other network devices.
- Connect the other end of the Ethernet cable to the RJ45 port of the switch.
Connecting the SFP/SFP+ Ports
- Plug the compatible SFP/SFP+ transceiver into the SFP/SFP+ port.
- Connect a fiber optic cable to the fiber transceiver. Then connect the other end of the cable to
another ber device.
WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules or optical fibers without eye protection.
Connecting the Console Port
- Insert the RJ45 connector into the RJ45 console port on the front of the switch.
- Connect the DB9 female connector of the console cable to the serial port on the computer.
Stacking the Switches
The S3910 series switches support stacking up to 4 units. Switches in the
series can be physically
stacked using optical ber cables connected to SFP/SFP+ transceivers or 1/10G
Direct Attach
Cables (DAC).
NOTE: 1. S3910-24TF switch supports stacking with the same models together. S3910-24TS/S3910-48TS switches support stacking with each other. 2. S3910-48TS switch only supports port 51 & 52 for physical stacking.
Configuring the Switch
Configuring the Switch Using the Web-based Interface
Step 1: Connect the computer to the business port of the switch using the
network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. (“x” is any
number from 2 to 254.)
Step 3: Open a browser, type http://192.168.1.1, and enter the default
username and password,
admin/admin.
Step 4: Click Login to display the web-based configuration page.
Configuring the Switch Using the Console Port
Step 1: Connect a computer to the switch’s console port using the console
cable.
Step 2: Start the terminal simulation software such as HyperTerminal on
the computer.
Step 3: Set the parameters of the HyperTerminal: 9600 bits per second, 8
data bits, no parity, 1 stop bit and no ow control.
Step 4: After setting the parameters, click Connect to enter.
Troubleshooting
1/10G Port is not Working
In the case of compatible cables and transceivers, the port cannot be up, please try to modify the port mode to adapt or force the port speed to 1/10G.
Connecting the Switch Remotely Unsuccessfully
- Test network connectivity through ping.
- If the network is reachable, try restarting the switch.
- Check if the corresponding service is enabled.
The Port is not Working, the LED Indicator is Off
- Ensure the switch ports are in the no shutdown state.
- Check if the switch can read the DDM information.
- Check if the port speed setting is correct.
- Try looping the switch cable.
Support and Other Resources
-
Download: https://www.fs.com/download.html
-
Help Center:https://www.fs.com/service/help_center.html
-
Contact Us:https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our
workmanship, we will oer a
free return within 30 Days from the day you receive your goods. This excludes
any custom made
items or tailored solutions.
Warranty: S3910 Series Switches enjoy 5 years limited warranty against
defect in materials
or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can
be found at
https://www.fs.com/policies/day_return_policy.html
Copyright © 2021 FS.COM All Rights Reserved.
Read More About This Manual & Download PDF:
References
- FS.com - HPC, Data Center, Enterprise, Telecom
- HPC, Data Centre, Enterprise, Telecom - FS.com United Kingdom
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- FS.com - Data Center, Enterprise, Telecom
- Contact Us - FS.com
- Kontakt - FS.com Deutschland
- Rückgaberecht - FS.com Deutschland
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- Technische Dokumente - FS.com Deutschland
- Hilfezentrum - FS.com Deutschland
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Comment Nous Contacter - FS.com France
- Politique de retour - FS.com France
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Documents techniques - FS.com France
- Centre d'aide - FS.com France
- Data Center, Enterprise, Telecom - FS.com
- Return Policy - FS.com
- Technical Documents - FS.com
- Help Center - FS.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>