Shenzhen Etross Telecom ETS-8848 4G LTE Fixed Wireless Terminal User Manual
- June 6, 2024
- Shenzhen Etross Telecom
Table of Contents
- Shenzhen Etross Telecom ETS-8848 4G LTE Fixed Wireless Terminal
- General Description
- Features:
- Technical Specifications:
- Operation Circumstance:
- Packing List
- Installation And Connection
- Function Setting
- Making Calls and Answer Incoming Calls
- Warranty Card
- FCC Warning Statement
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Shenzhen Etross Telecom ETS-8848 4G LTE Fixed Wireless Terminal
General Description
4G LTE FWT ETS-8848 is a 4G Lte to Analog Converter, the device can produce a
FXS line to allow a regular phone to be connected and used just like a local
landline(PSTN) except your calls will go out from the 4G network. This device
can both receive and make calls.
The main applications are: Connecting the RJ-11 FXS line to an ordinary
telephone set for a voice call; connecting PBX for call extensions; to
connecting billing systems for public phone use; to connect VoIP FXO gateway
to realize VoIP call termination; to connect alarm system for security
purpose, etc.
It is a 4G LTE Fixed Wireless Terminal that produces an analog FXS phone line.
Module employed:
Quectel 4G LTE Standard EC2x(EC25、EC21、EC20 R2.0 and EC20 R2.1) /EG21-G/EC200T
etc.for different countries and networks.
Appearance and Structure
Item | 4G LTE FWT ETS-8848 | Remark |
---|---|---|
Appearance | White/black | |
Material | ABS (Acrylonitrile Butadiene Styrene) | |
Dimension | 170mm×118mm×30mm | Excluding antenna |
Weight | 250g | Weight of Main unit |
Power Switch | Rocker switch | |
--- | --- | --- |
Power Socket | 12V DC input | |
Phone interface | RJ11 | 2 RJ-11 ports |
Antenna interface | SMA – Female | |
LED display | No.1: Power, No.2.in use, No.3, in talk, No.4, Battery, if have, | |
No. 5-7, Signal strength | From left to right(front side view) | |
Front side | LEDs display for Signal strength, Power, Working Status,Talking | |
and Battery indicator; | ||
Rear side | 1 piece SMA antenna connectors, 2 RJ-11 output, Power port and | |
switch; | ||
Bottom side | 1 piece SIM slot |
Features:
- It is a 1 port 4G LTE fixed wireless terminal which has 2 RJ-11 outputs for extensions;
- It supports VoLTE function.
- It can connect with ordinary telephone set, PBX , VOIP Gateway, Billing meter etc.
- Employ industrial module Quectel EC2X series to make
- Simple to install and easy to maintain
- Steady module and reliable design ensures good performance
- Provides optimized circuit directly connecting the exchange device for extensions
- Compatible to most telephones, PBX device.
- Strong signals with high gain antenna
- Attractive plastic casing
- SIM card supported (1.8V, 3V)
- Caller ID display
- Support DTMF/FSK
- Provides reversal polarity signal for metering
- No noise and clear voice
- Suitable for wide voltage range and low power consumption
- Suitable for all kinds of weather and environment
- Locking PIN / network (optional)
Technical Specifications:
Air interface standard:
Quectel 4G LTE standard module EC2X is a wireless module which is designed for
the global market.it can be designed in many kinds of applications which can
work on 4G LTE network.
Quectel 4G LTE module EC2X support the Bands as the following:
EC25-EUX for example:
LTE FDD: B1/B3/B7/B8/B20/B28A
LTE TDD: B38/B40/B41
WCDMA: B1/B8
GSM/EDGE: B3/B8
For other modules,please refer Quectel website http://www.quectel.com to
choose the correct module.
- Phone interface: supply RJ-11 Phone Interface
- Hanging voltage: 45V
- Picking off voltage: 30mA / 41mA
- Dialing tone Frequency: 450Hz
- Antenna interface: Antenna amplifying>2.5db
- Sensitivity: <-104DBM
- Transmitting power<3W
- Color: White /Black (optional)
- AC-Adapter interface: Input: AC100-240V 50/60Hz 0.4A Max
- Output: 12.0VDC = 1.0A.
- AC-Adapter type: EU, US, AU, British type (can be optional)
- Back up battery: Li-ion battery 900mAh 7.4V 6.7WH (Can be optional)
Operation Circumstance:
- Operation temperature: -10c~60C
- Storage temperature:-20C~70C
- Operation humidity:45%-95%
- Atmosphere pressure:86-106Kpa
- Environment noise: <60DB
- Transmitting Power:2W
- Sensitivity: <-104dbm
- Antenna Amplifying: >2.5db
- Dialing frequency: 450Hz
- Hanging voltage: 45V
- Picking current: 30mA/41mA
Packing List
Name | Quantity | Remark |
---|---|---|
4G LTE FWT ETS-8848 | 1 piece | 4G LTE |
Ac- adapter | 1 piece | AC100-240V, DC12V/1A |
Antenna | 1 piece | Magnetic based Antenna with |
3m cable
User’s Manual| 1 piece| English
G.W: 0.75kg per unit. 20pcs/Carton, 16kg /Carton
Carton Box Size: 55cmX34.5cmX32.5cm
Installation And Connection
The Condition for Installation
The terminal asks for 110- 220V AV power supply. It must be installed in the
area where the 4G network can cover. The strength of the signal can affect the
quality of voice.
- Insert SIM card into the SIM card holder at the back of the terminal.
- Install antenna. In order to ensure the quality of voice, the antenna must be put beyond 1.5 from the telephone and terminal.
- On end of the telephone line connects to the “Phone” port of the terminal, the other end connects to telephone.
- “Power” port connects to power adapter that is connected to 110-220V AC power supply.
The Installation for Connecting to Ordinary Telephone
The Sketch for connecting ordinary Telephone
Draw your attention: Because there are many types of ordinary telephone and their electric parameters are different. In order to avoid mutual disturbance between telephone and terminal and affect voice quality. The distance between telephone and terminal is 1.5m at least.
The installation for connecting to billing device for metering
If the users demand to register cost during calls, billing device can be
connected between terminal and ordinary telephone. Billing device register
cost according to the anti-polarity signal that is provided by the terminal.
The sketch for connecting to Billing device or Computer charging system
The installation for
connecting to PBX for call extensions
If users want to connect small PBX to this terminal, connect terminal’s “Phone
port” to the PBX.
The sketch for connecting to PBX device.
The installation for connecting VoIP gateway for Call Termination
Suppose a VoIP call originates from US, which was transferred from US Server
to China Server on VoIP, finally the call will be terminated from internet to
4G LTE network and to be sent out to the destination answer side.
The sketch for connecting to VoIP gateway
The installation for connecting to alarm system for Security
The 4G LTE FWT can substitute the PSTN for connecting to alarm system for
security purpose when PSTN failure or not available.
The sketch for connecting to alarm system
Function Setting
Before you do the following function settings, Lift handset or press hands
free key of telephone set, then you can press the buttons according to the
following instructions to finish setting, you will hear 2 beeps after you
finish, that means set successfully.
Before you start to make setting, Enter ***28167031#, Then you can do the
following settings according to your needs.
- Restore to factory default setting
*#99#99# restore to factory default setting. - Adjust dial interval
*#01#30# , 01–command,30–time,Max 9.9 seconds,Min 0.5 seconds, default setting is 3 seconds.
-
If you use 4G LTE FWT ETS-8848 for connecting to VoIP gateway, you can set dial interval as 0.5 second, it can make PDD<5 sec (Method: *#01#05#);
-
If you use 4G LTE FWT ETS-8848 for connecting telephone, PBX, billing device, you can set dial interval as 3 seconds or 5 seconds as you like (Method: #01#30#, set the dial interval as 3 seconds). 3. Adjust Earphone Volume
#02#15# 02–command,15–volume,Max 16,Min 1, default setting is 15. 4. Adjust Mic. Volume (sensitivity)
#03#10# 03–command,10–amount,Max 16,Min 1, default setting is 10. 5. Setting local area code
#04#0755# 10–command,0755—area code,Max 5 numbers, use “” instead if area code is less than 5 digits. 6. Setting IP numbers
#05#17911# 05–command,17911—IP numbers,Max 5 numbers, use “” instead if IP number is less than 5 digit. 7. Hide Caller ID (been sent out)Setting
#13#01# 13–command,01–value,Max-02,Min-00 Default setting is 00
00– presentation indicator is used according to the subscription of the CLIR service
01 – CLIR allowed
02 – CLIR prohibited
Notice: This Setting must need carrier’s support.-
Bar incoming call Setting
*#14#00# 14–command,00–value,00–no barring, 01–set barring default setting –00 -
FSK setting (optional) (should confirm before order)
*#17#00# setting caller ID
17-order, 00-value, 00-DTMF, 01-FSK, default setting is 00
This setting need terminal has FSK Chip set support -
Billing Mode setting
*#15#00#
15–command, 00-value, 01-reversal polarity, 02-12 KHz, 03-16 KHz, default setting– 01 -
Pin Lock &Network Lock Setting (optional)(Should confirm before order)
-
PIN Lock
-
Set to open PIN code check and automatic PIN lock function
#07#1234# 07-command, 1234- the current SIM card PIN code
If set sucessfully, the device will open PIN code check, and automatically change the current SIM Card into “PIN on” from “PIN off” -
Set to close PIN code check and auomatic PIN lock function
#08#1234# 08-command, 1234- the current SIM card PIN code
If set sucessfully, the device will close PIN code check and automatic PIN lock function. -
Set to change PIN code, open automatic PIN lock function
#09#123456785678# 09-command, 1234- the current sim card PIN code, 5678-new PIN code. (5678 can be any other 4 digits number, suppose you can use 2009).
If set successfully, the device will change the current sim card PIN code as you want.5678, or the any other 4 digit PIN codes, and open automatic PIN lock function.
Network Lock
- Set to open Network lock function
*#10#01234# 10-command, 01234-password - Set to close Network lock function
*#11#01234# 11-command,01234-password - Set the Network codes
#12#14600346003# 12-command,1–No. Of IMSI, 46003–the IMSI code for China Telecom
#12#24600046000# 12-command, 2–No. Of IMSI, 46000–the IMSI code for China Mobile
Making Calls and Answer Incoming Calls
Making Calls
- Lift the handset or press “hand-free” key, you will hear dialing tone, then you can dial the telephone numbers you want to call.
- Dialing: dialing the telephone numbers you want to call
- On completion of dialed digits, you can press “#” to transmit the called telephone numbers. If you don’t dial any key for continual 3 seconds during the dialing, terminal transmits called telephone numbers automatically.
- During calls, if the telephone numbers is not free ones, the terminal sends out anti-polarity signal.
- If the calling party or called party hangs up, the terminal stops sending out anti-polarity signal.
Answering Incoming Calls
When a call is coming in, if the connected telephone has the function of
displaying incoming call, the telephone rings and displays the incoming
telephone number. Now the user can lift the handset or press “hand-free” to
answer it.
Warranty Card
Please fill in the blanks carefully, and keep it properly as the voucher for warranty.
Type of Equipment | 4G LTE FWT ETS-8848 |
---|---|
User’s name | |
Contact Tel.no. | |
Address | |
Date of Ex-works | |
Date of Maintenance | Damage |
Sales Agent (Stamp) |
FCC Warning Statement
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RF Exposure Statement
To maintain compliance with FCC’s RF Exposure guidelines, This equipment
should be installed and operated with minimum distance of 20cm the radiator
your body. This device and its antenna(s) must not be co-located or operation
in conjunction with any other antenna or transmitter.