MOTION QUANTUM IP68 MQ Digitalized Motion User Manual
- June 6, 2024
- MOTION QUANTUM
Table of Contents
Motion Quantum brings you the essence of digitalized motion.
The Oxygen
The kit includes:
- 1 Nucleus – central unit
- 8 Electrons – sensors
- 2 charging cables for Electrons
- 1 charging cable for Nucleus
- 1 Nucleus holder
- Foam for sensor calibration
Interfaces of Nucleus and Electrons
Charging
To charge the devices plug them into the USB slot using a micro USB cable (on the Nucleus/Electron side). Please note that the devices can be used while plugged in and charging, but certain operations are not advised, like sensor calibration.
LED status
The LED mode on the Nucleus and Electron can change based on the battery, charging, and internal states. The battery and charging-related LED modes can be seen in the next table.
State of device | Corresponding LED behavior |
---|---|
Low battery (<10%) | Short red blink is a period |
Charging | Green pulsating light is a period |
Fully charged | Short green blink is a period |
Turning on/off
- The sensor can be switched on by connecting the sensor to a power source through the micro USB connector (as if to charge the batteries).
- The sensor can also be switched on by shaking it firmly (when using wake on motion). When awoken the led will light up.
- The Nucleus and Electron will switch off automatically after 15mins if there are no active connections.
Restart
In case of a restart, the devices will lose any connection and ongoing
measurement.
Hard reset – upon connecting the device to a power source through the micro
USB connector the device will reset.
Long-term storage guidelines
Follow the recommended guidelines to preserve the battery life of the devices:
- Operating temperature: 0°C – 50°C.
- Storage temperature: 25°C±10°C.
If the devices will be stored for a prolonged period, charge all devices up to at least 90%.
Electron:
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
CAUTION: The grantee is not responsible for any changes or modifications
not expressly approved by the party responsible for compliance. Such
modifications could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or
more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This equipment has been tested and meets applicable limits for radio frequency
(RF) exposure. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
Nucleus:
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
CAUTION: The grantee is not responsible for any changes or modifications
not expressly approved by the party responsible for compliance. Such
modifications could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This equipment has been tested and meets applicable limits for radio frequency
(RF) exposure. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
RF exposure statement
This equipment complies with the FCC RF radiation exposure limits set forth
for an uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 20cm between the radiator and any part of
your body.
Contains FCC ID: 2AC7Z-ESPWROOM32D
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>