Replacing Measuring Unit
NOTICE
Risk of damage to the equipment!
- Clean and dry the probe well before opening!
- Do not use compressed air to clean the touch probe!
- When inserting the new measuring unit, ensure that the O-rings inside the touch probe housing and on the measuring unit are properly seated!
-
Remove the stylus according to chapter 2.2.1.
-
Remove the battery from the touch probe according to chapter 2.2.3.
-
Insert the C-spanner into the bores of the measuring unit and carefully unscrew the measuring unit in a counter-clockwise direction.
-
Insert the new measuring unit into the touch probe and carefully screw it in by hand.
-
Insert the C-spanner into the bores of the new measuring unit, screw the measuring unit completely to the stop.
-
Mount the stylus according to chapter 2.2.1.
-
Reinsert the battery into the touch probe according to chapter 2.2.3.
INFORMATION
After changing the battery, the time for starting the touch probe (reboot) is approx. 5 s! -
Align the stylus to spindle centre.
-
Calibrate the probe. Replacing Measuring Unit (Example: PP41.00 - > MY21.00)
Force setting (Measuring Unit PP41.00 only)
INFORMATION
In the case of strong vibrations in the machine or when using heavy probe
inserts, an increase in the trigger force may improve the measuring results.
- Unscrew the stylus (refer to chapter 2.2.1).
- Use an AF1.3 mm hexagon key to increase or decrease the trigger force (refer to Fig. 18). Adjusting trigger force
Revolutions based on lowest force setting| ≈ Trigger force with 50 mm stylus in N
---|---
Z| X/Y
min. 0| 2.5| 0.3
1| 3.5| 0.4
2| 4.5| 0.5
3| 5.5| 0.6
4| 6.5| 0.7
5| 7.5| 0.9
6| 8.5| 1
7| 9.5| 1.1
8| 10.5| 1.2
9| 11.5| 1.3
max. 10| 12.5| 1.4 - Screw in the stylus (refer to chapter 2.2.1) and align the stylus to the spindle centre (refer to chapter 2.2.5).
- Calibrate the probe.
Maintenance and Cleaning (Measuring Unit PP41.00 only)
NOTICE
Risk of damage to the equipment!
- Clean and dry the probe well before opening!
- Do NOT clean with compressed air or high pressure water!
- Do NOT use any sharp tools (these could damage the inner seal)!
-
Unscrew the stylus.
INFORMATION
Dirt can collect under the metal eyelid. -
Remove the service cover with metal eyelid and conical spring by hand.
-
Clean the touch probe and components under running water.
-
Reassemble all parts.
-
Align the stylus to spindle centre.
-
Calibrate the probe! Maintenance and cleaning of the radio-wave touch probe TP-R-400
Modular System (for Measuring Units PP41.00 and MY21.00 only)
NOTICE
Risk of material damage/damage to the equipment!
- Wipe the probe clean and dry before dismounting!
- Do not use compressed air to clean the touch probe!
- When screwing in the extension, make sure the O-ring is properly seated.
- The probe may be extended by a maximum of 200 mm!
- Align probe in the spindle axis to the spindle centre.
- Calibrate the touch probe. Modular system
Measuring Unit Extensions Order Number Length
21.00-VE30 30 mm (1.18”)
21.00-VE50 50 mm (1.97”)
41.00-VE100 100 mm (3.94”)
41.00-VE200 200 mm (7.87”)
EU Declaration of Conformity
This declaration of conformity is issued under the sole responsibility of m&h Inprocess Messtechnik GmbH
Manufacturer/ Representative m&h lnprocess Messtechnik GmbH
Am Langholz 11 88289 Waldburg Germany
Product name: Radio-wave touch probe
Model / Type: TP-R-400
The product mentioned above meets the requirements of the following relevant directives/ standards:
Directive / Standard | Issue | Title / Section |
---|---|---|
2011/65/EU | 2011 | Restriction of the use of certain hazardous substances in |
electrical and electronic equipment
2014/53/EU| 2014| Making radio equipment available on the market
2014/30/EU| 2014| Electromagnetic compatibility
ETSI EN 300328| 2019| Wideband transmission systems – Data transmission
equipment operating in the 2,4 GHz ISM band and using wide band modulation
techniques
ETSI EN 301489-1| 2019| ElectroMagnetic Compatibility (EMC) standard for radio
equipment and services – Part 1
ETSI EN 301489-17| 2020| ElectroMagnetic Compatibility (EMC) standard for
radio equipment and services – Part 17
EN ISO 12100| 2010| Safety of machinery – General principles for design – Risk
assessment and risk reduction
EN 62368-1| 2014| Audio/video, information and communication technology
equipment – Part 1: Safety requirements
C E| |
Date 15.07.2021
Place, Waldburg,
UKCA Declaration of Conformity
This declaration of conformity is issued under the sole responsibility of m&h Inprocess Messtechnik GmbH
Manufacturer/ Representative: m&h lnprocess Messtechnik GmbH
Am Langholz 11 88289 Germany
Product name: Radio-wave touch probe
Model / Type: TP-R-400
The product mentioned above meets the requirements of the following relevant directives/ standards:
Directive / Standard | Issue | Title / Section |
---|---|---|
2011/65/EU | 2011 | Restriction of the use of certain hazardous substances in |
electrical and electronic equipment
2014/53/EU| 2014| Making radio equipment available on the market
2014/30/EU| 2014| Electromagnetic compatibility
ETSI EN 300328| 2019| Wideband transmission systems – Data transmission
equipment operating in the 2,4 GHz ISM band and using wide band modulation
techniques
ETSI EN 301489-1| 2019| ElectroMagnetic Compatibility (EMC) standard for radio
equipment and services – Part 1
ETSI EN 301489-17| 2020| ElectroMagnetic Compatibility (EMC) standard for
radio equipment and services – Part 17
BS EN ISO 12100| 2010| Safety of machinery – General principles for design –
Risk assessment and risk reduction
BS EN 62368-1| 2014| Audio/video, information and communication technology
equipment – Part 1: Safety requirements
Place Waldburg
Date 15.07.2021
Machine Tool Measurement
c/o m&h lnprocess Messtechnik GmbH Am Langholz 11 88289 Waldburg Germany
Tel. +49 (0 )7529 9733 0
Fax+49( 752997337
sales.mh@hexagon.com
Hexagon is a global leader in sensor, software and autonomous solutions. We are putting data to work to boost efficiency, productivity, and quality across industrial, manufacturing, infrastructure, safety, and mobility applications
Our technologies are shaping urban and production ecosystems to become increasingly connected and autonomous – ensuring a scalable , sustainable future.
Hexagon’s Manufacturing Intelligence division provides solutions that utilise data from design and engineering, production and metrology to make manufacturing smarter. For more information, visit hexagonmi.com.
Learn more about Hexagon (Nasdaq Stockholm: HEXA B) at hexagon.com and follow us @HexagonAB
2020 Hexagon AB and/or its subsidiaries and affiliates. All rights reserved.
Documents / Resources
| M H
Inprocess Messtechnik TP-R-400 Radio Wave
Probe
[pdf] Instruction Manual
R400, MFFR400, Radio Wave Probe, TP-R-400 Radio Wave Probe, Wave Probe
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>