Features and Benefits

  • EcoNet® Enabled: Automatic system configuration and optimization
  • Diagnostics & Bluetooth®1 Connectivity: With the Russell® By Rheem Contractor & EcoNet® Apps, built-in technology makes advanced set-up, monitoring, troubleshooting and repairing the product easier than ever before
  • Variable Speed Twin Rotary Compressor & Inverter Drive: Features Inverter operation from 40 to 100% capacity with the EcoNet® Smart Thermostat
  • 3-Speed Operation: When installed with a 24V two-stage thermostat
  • Provides Precise Temperature Control: Advanced humidity control and greater efficiency
  • Brushless DC Condenser Motors (BLDC): Enhances reliability and allows for easier serviceability
  • Swept Wing Fan Technology: Features quieter operation and improved unit acoustics
  • 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
  • Expanded Valve Space : 3 in. – 4in. – 5 in. service valve space—provides a minimum working area of 27-square inches for easier access
  • Triple Service Access : 15 in. wide, industry leading corner service access, two fastener, removeable corner and individual louver panels—makes repairs easier and faster

Air Conditioners

S A 16 A Z 24 A J 3 C A LHP
Brand Product Category SEER2 Region Refrigerant Capacity BTU/HR Major
Series Voltage Type Controls Minor Series Option Code

S – Russell® By Rheem A – Air Conditioners 16 – 16 SEER2 A – All Z – R-410A

  • 24-24,000 [7.03 kW]
  • 36-36,000 [10.55 kW]
  • 48-48,000 [14.07 kW]
  • 60-60,000 [17.58 kW] A – 1st Design J – 1ph, 208-230/60 3 – 3+ Stage C – Communicating A – 1st Design LHP – W/HLPC

[ ] Designates Metric Conversions

AVAILABLE MODELS DESCRIPTION
SA16AZ24AJ3CA Vantix™ Line 2 ton EcoNet® Enabled 3+ Speed iM Air Conditioner

– 208/230/1/60
SA16AZ36AJ3CA| Vantix™ Line 3 ton EcoNet® Enabled 3+ Speed iM Air Conditioner – 208/230/1/60
SA16AZ48AJ3CA| Vantix™ Line 4 ton EcoNet® Enabled 3+ Speed iM Air Conditioner – 208/230/1/60
SA16AZ60AJ3CA| Vantix™ Line 5 ton EcoNet® Enabled 3+ Speed iM Air Conditioner – 208/230/1/60
STANDARD EQUIPMENT

R-410A Refrigerant
Scroll Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Single row condenser coil
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays

*5T Model SEER2: 15.5 SEER2

General Data

MODEL NO.| SA16AZ24AJ3| SA16AZ36AJ3| SA16AZ48AJ3| SA16AZ60AJ3
Nominal Tonnage| 2.0| 3.0| 4.0| 5.0
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 91| 119| 130| 154
Compressor Type| Twin Rotary
Outdoor Coil|
Net face area – Outer Coil| 11.79| 14.4| 16.42| 17.88
Net face area – Inner Coil| —| —| —| —
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276
Number of rows| 1| 1| 1| 1
Fins per inch| 24| 24| 24| 24
Outdoor Fan|
Diameter – in.| 20| 24| 24| 26
Number of blades| 3| 3| 3| 3
Motor hp| 1/5| 1/5| 1/3| 1/2
CFM| 2883| 4138| 4508| 5348
RPM| 1075| 1000| 1075| 1075
watts| 168| 267| 297| 379
Shipping weight – lbs.| 153| 157| 195| 211
Operating weight – lbs.| 146| 150| 188| 204
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20| 30| 40| 50
Minimum circuit ampacity5| 12| 20| 25| 32
Compressor|
Rated load amps| 10| 15| 20| 25
Locked rotor amps| 65| 70| 96| 119

  1. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
  2. HACR type circuit breaker of fuse.
  3. Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.

Accessories

MODEL NO.| SA16AZ24AJ3| SA16AZ36AJ3| SA16AZ48AJ3| SA16AZ60AJ3
---|---|---|---|---
Compressor crankcase heater*| x| x| x| x
Low ambient control| Factory Installed| Factory Installed| Factory Installed| Factory Installed
Compressor sound cover| Factory Installed| Factory Installed| Factory Installed| Factory Installed
Compressor hard start kit| Factory Installed| Factory Installed| Factory Installed| Factory Installed
Compressor time delay| Factory Installed| Factory Installed| Factory Installed| Factory Installed
Low pressure control| x| x| x| x
High pressure control| Factory Installed| Factory Installed| Factory Installed| Factory Installed
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V

Weighted Sound Power Level (dBA)

UNIT SIZE – VOLTAGE, SERIES| STANDARD RATING (DBA)| TYPICAL OCTAVE BAND SPECTRUM (DBA WITHOUT TONE ADJUSTMENT)| SOUND POWER LEVEL [DB(A)] WITH SOUND BLANKET
---|---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
SA16AZ24AJ3| 63.3| 35.9| 47.9| 55.3| 53.2| 50.4| 47.1| 43.8| **** Sound Blankets – Standard
71.7| 46.1| 59.1| 63.2| 60.8| 58.7| 56.5| 47.9
SA16AZ36AJ3| 61.4| 38.5| 48.0| 53.8| 49.2| 45.9| 47.0| 47.4
72.9| 47.5| 59.5| 64.9| 60.7| 62.6| 57.0| 49.6
SA16AZ48AJ3| 63.8| 42.3| 45.9| 53.5| 48.9| 45.8| 59.1| 36.4
76.2| 49.4| 61.4| 68.1| 53.9| 60.8| 57.4| 48.5
SA16AZ60AJ3| 65.7| 39.7| 49.0| 58.2| 54.5| 52.2| 53.8| 41.3
76.7| 49.3| 64.6| 68.1| 65.1| 62.6| 58.6| 53.0

NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI

Unit Dimensions

**MODEL NO.** OPERATING SHIPPING
H (Height) L (Length) W (Width)
(Length)** W (Width)
INCHES mm INCHES
mm INCHES mm
SA16AZ24AJ3 27.00 686
32.38 822
SA16AZ36AJ3 27.00 686
36.38 924
SA16AZ48AJ3 31.00 787
36.38 924
SA16AZ60AJ3 31.00 787
38.38 975

Dimension

CLEARANCES

Table

Control Wiring

FIGURE 2
Table

CONTROL WIRING FOR GAS OR OIL FURNACE

FOR TYPICAL GAS OR OIL HEAT

BR – BROWN WIRE
YL – YELLOW WIRE
X – WIRE CONNECTION

  • IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED, IT IS RECOMMENDED THAT W1 (W/BK) AND W2 (W/BL) BE JUMPERED TOGETHER.

FOR TYPICAL GAS OR OIL HEAT FOR TYPICAL ELECTRIC HEAT
Table
BR – BROWN WIRE
R – RED WIRE
YL – YELLOW WIRE
W/BK – WHITE WIRE WITH BLACK STRIPE
G/BK – GREEN WIRE WITH BLACK STRIPE
PU – PURPLE WIRE (NOT USED)
X – WIRE CONNECTION

Application Guidelines

  1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
  2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
  3. Maximum outdoor operating air temperature is 125°F (51.7°C).
  4. For reliable operation, unit should be level in all horizontal planes.
  5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
  6. Do not apply capillary tube indoor coils to these units.
  7. Factory-supplied filter drier must be installed.

Refrigerant Line Size Information

15/16 SEER2 VARIABLE SPEED AIR CONDITIONERS

**UNIT SIZE| ****ALLOWABLE LIQUID LINE SIZE| ****ALLOWABLE VAPOR LINE SIZE| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (FEET)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150
MAXIMUM VERTICAL SEPARATION / CAPACITY MULTIPLIER
**
2.0 Ton **SEE NOTE 3| 1/4″| 5/8″| 25/1.00| 50/0.99| 32/0.98| 40/0.97| NR| NR
5/16″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
3/8″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
1/4″| 3/4″| 25/1.00| 50/1.00| 32/0.99| 40/0.99| NR| NR
5/16″| 3/4″
| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3/8″| 3/4″| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
**
3 Ton| 5/16″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 37/0.91| NR
3/8″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
5/16″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 37/0.97| 22/0.96
3/8″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
1/2″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
**** 4 Ton| 3/8″| 3/4″| 25/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.94| 50/0.93
1/2″| 3/4″| 25/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.94| 50/0.93
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
**** 5 Ton| 3/8″| 3/4″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
1/2″| 3/4″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.98| 50/0.97| 38/0.96
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.98| 50/0.97| 50/0.96

NOTES:

  1. Do not exceed 150 ft. linear line length.
  2. *Do not exceed 50 ft. vertical separation if outdoor unit is above indoor unit.
  3. **3/4″ suction line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

15/16 SEER2 VARIABLE SPEED AIR CONDITIONERS

**UNIT SIZE| ****ALLOWABLE LIQUID LINE SIZE| ****ALLOWABLE VAPOR LINE SIZE| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (METERS)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150
MAXIMUM VERTICAL SEPARATION / CAPACITY MULTIPLIER
**
2.0 Ton **SEE NOTE 3| 6.35 [1/4]| 15.88 [5/8]| 8/1.00| 15/0.99| 10/0.98| 10/0.97| NR| NR
7.94 [5/16]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
9.53 [3/8]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
6.35 [1/4]| 19.05 [3/4]| 8/1.00| 15/0.99| 10/0.99| 12/0.99| NR| NR
7.94 [5/16]| 19.05 [3/4]
| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99| 15/0.98
9.53 [3/8]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99| 15/0.98
**
3 Ton| 7.94 [5/16]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 11/0.91| NR
9.53 [3/8]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
7.94 [5/16]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 11/0.97| 7/0.96
9.53 [3/8]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96
12.7 [1/2]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96
**** 4 Ton| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.94| 15/0.93
12.7 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.94| 15/0.93
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97
12.7 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97
**** 5 Ton| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
12.7 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.98| 15/0.97| 12/0.96
12.7 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.98| 15/0.97| 15/0.97

NOTES:

  1. Do not exceed 46 meters linear line length.
  2. *Do not exceed 15 meters vertical separation between indoor and outdoor units.
  3. **19.05mm [3/4″] vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

ADDITIONAL OIL, OZ.

LINESET LENGTH| 50| 60| 70| 80| 90| 100| 110| 120| 130| 140| 150
2T| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6| 7
3T| N/A| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6
4T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A
5T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A

Performance Data @ AHRI Standard Conditions – Cooling

DESIGNATED TESTED COMBINATION (DTC)

OUTDOOR UNIT| INDOOR COIL| TOTAL CAPACITY BTU/H [KW]| NET SENSIBLE BTU/H [KW]| NET LATENT BTU/H [KW]| SEER2| EER2| INDOOR CFM [L/S]
SA16AZ24AJ3C| SH3VZ2417STACN| 22,800 [6.7]| 17,600 [5.2]| 5,200 [1.5]| 16.0| 10.5| 750 [354.0]
SA16AZ36AJ3C| SH3VZ3617STACN| 34,200 [10.0]| 26,600 [7.8]| 7,600 [2.2]| 16.0| 10.5| 1,125 [530.9]
SA16AZ48AJ3C| SH3VZ4821STACN| 45,500 [13.3]| 35,500 [10.4]| 10,000 [2.9]| 16.0| 10.5| 1,425 [672.5]
SA16AZ60AJ3C| SH3VZ6024STACN| 55,500 [16.3]| 43,000 [12.6]| 12,500 [3.7]| 15.5| 9.8| 1,675 [790.5]

NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.

[ ] Designates Metric Conversions

Integrated Controls

EcoNet® is smart, technology that allows Heating and Cooling, products to communicate with each other on one integrated network

THE ECONET® SMART THERMOSTAT

BUILT-IN WIFI
4.3″ LCD TOUCH SCREEN
LOCAL WEATHER – Current conditions plus 6-day forecast
5 OPERATING MODES – Heat, Cool, Auto, Emergency Heat and Fan Only
7-DAY PROGRAMMABLE SCHEDULE – Offers comfort without thought
ONE-TOUCH AWAY – Quickly switch to your energy-saving away preferences
VACATION SCHEDULING – Allows you to save while you’re away and come home to comfort
STANDBY SCREEN – Displays indoor temperature and current weather

CETST800SYS
Screen Display

OPERATIONAL FEATURES

AUTOMATIC CHANGEOVER – Transitions between heating and cooling automatically to keep the house comfortable
INTEGRATED WATER CONTROL – Enables easy water heater management
SMOOTH ARRIVAL – Prompts the system to start ahead of schedule to ensure the home is at the desired temperature at the scheduled time
HUMIDITY CONTROL – Supports humidifier accessories or over-cool based dehumidification
DETAILED OPERATING STATUS – View pertinent equipment status information and run times
CONTINUOUS FAN – Offers 5 speeds (Low, Medium Low, Medium, Medium High, High)
SHORT-CYCLE PROTECTION – Avoids damage to equipment from short run cycles

MONITORING & REMOTE CONTROL FEATURES

ACTIVE MONITORING – Alerts to problems that need immediate attention
REMOTE CONTROL – Allows adjusting of comfort and settings from anywhere using a mobile device
SERVICE ALERTS – Sends routine maintenance reminders
AIR FILTER MONITORING – Detects when it’s time to replace the air filter
ALARM HISTORY – Displays time-stamped alarm codes with clear descriptions

GENERAL TERMS OF LIMITED WARRANTY*

Russell® By Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty

For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.

Conditional Unit Replacement
(Registration Required)………………………………Ten (10) Years
Parts ………………………………………………………..Ten (10) Years

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.

© 2023 Rheem Manufacturing Company. Russell By Rheem trademarks owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement, Russell by Rheem reserves the right to make changes without notice.

Russell by Rheem • 5600 Old Greenwood Road
Fort Smith, Arkansas 72908 • www.russellbyrheem.comRussell
Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Russell User Manuals

Related Manuals