EYENOVIAGEN1 Optejet Base G1 Instructions
- June 6, 2024
- Eyenovia
Table of Contents
EYENOVIAGEN1 Optejet Base G1 Instructions
NOTES ON SAFETY
WARNING: Do not use with non-certified USB Charger:
Device is intended to be recharged using MicroUSB cable (not included). Use of
USB charger other than those specified or provided in the recommended USB
Charger list could result in increased electromagnetic emissions or decreased
electromagnetic immunity of this equipment and result in improper operation.
WARNING: Do not use after expiration date:
Expiration dates are published on the back label for the MydCombi™ Base
Unit. Use of Base Units should be discontinued if the expiration date has
passed.
WARNING: Inspect for device damage:
Do not use if package has been previously opened or damaged. Do not use the
MydCombi™ Base Unit if there is evidence of damage. Doing so could result in
injury.
WARNING: Tampering of parts in the MydCombi™ Base Unit:
Do not tamper with or attempt to open up the parts of the MydCombi™ Base
Unit. Doing so could cause damage to the unit and result in personal injury.
WARNING: Risk of usage:
Failure to use the MydCombi™ Base Unit in accordance with these instructions
could result in complications during dose dispensing. If the MydCombi™ Base
Unit has been idling for an extended amount of time, a waste dose shot should
be dispensed. The MydCombi™ Base Unit must be kept in the upright position
during use.
WARNING: Risk due to insufficient user training:
Training is required prior to use of the MydCombi™ Base Unit. The user should
be adequately trained in handling the MydCombi™ Base Unit prior to use. The
MydCombi™ Cartridge is designed to solely interface with the MydCombi™ Base
Unit. Refer to the MydCombi™ Cartridge instructions for use.
WARNING: Risk due to battery leakage:
If there is any sign of battery leakage, do not use the MydCombi™ Base Unit.
WARNING: Keep Dry:
The MydCombi™ Base Unit should not be exposed to water and should be kept dry.
WARNING: Transportation and Storage:
Do not store or transport the MydCombi™ Base Unit where it can encounter sharp
or metallic objects.
WARNING: Risk of electrical leakage:
Non-hazardous voltage is present during normal use.
WARNING: Do not use with other equipment:
Use of this equipment adjacent to or stacked with other equipment should be
avoided because it could result in improper operation. If such use is
necessary, this equipment and the other equipment should be observed to verify
that they are operating normally.
WARNING: Do not use with non-certified USB Charger:
Device is intended to be recharged using MicroUSB cable (not included). Use of
USB charger other than those specified or provided in the recommended USB
Charger list could result in increased electromagnetic emissions or decreased
electromagnetic immunity of this equipment and result in improper operation.
CAUTION: For professional use:
Federal law restricts this device to sale by or on the order of a physician
(21 CFR §801.109(b)(1)).
CAUTION: Radiation Emission:
This equipment emits radiation.
OPERATION
NOTE: If the packaging is opened or damaged, do not use the contents. Instead, contact Eyenovia at admin@eyenoviabio.com
HOW TO STORE the MydCombi™ Base Unit
Store in a secure location at room temperature 59-85°F (15-30°C) away from direct sunlight and excessive heat.
- Do not heat or freeze the MydCombi™ Base Unit
- Do not get the MydCombi™ Base Unit wet or expose to fluids.
- Do not tamper with or attempt to open the parts of the MydCombi™ Base Unit.
The MydCombi™ Base Unit contains a lithium ion battery1.
CHARGING the MydCombi™ Base Unit
Before beginning:
- If packaging is opened or damaged, do not use the contents. Instead, get a new package.
- A USB Cable is required to charge the MydCombi™ Base Unit.
- The cable can be connected either to a wall outlet plug or to a USB port.
- The MydCombi™ Base Unit must be charged before first use.
- Charging may be performed either before or after cartridge assembly attachment.
Perform these steps to charge Optejet base:
- Push USB cable into charging port.
- Connect opposite end of USB cable to wall outlet plug or USB port.
- Battery light BLINKS GREEN while charging.
- Charge until battery light turns SOLID GREEN and remove charging cable from base.
Note: Excessive charging may decrease the battery life. Weekly charging or charging once the LED light starts blinking red (signaling a low battery), is preferable.
MydCombi™ Base Unit BATTERY INDICATORS
If you see… | It means… |
---|
Mirror Light AND Battery Light
SOLID BLUE
| Ready to dose
Battery Light BLINKING GREEN| Battery is charging
Battery Light SOLID GREEN| Battery is fully charged
Battery Light BLINKING RED| Battery is low
Battery Light SOLID RED| Charge MydCombi™ Base Unit
Mirror Light AND Battery Light
BLINKING BLUE
This happens if you do not use the medicine within 1 minute after it is
loaded
| Warning for automatic medicine discharge
Mirror Light BLINKING BLUE AND Battery Light BLINKING RED
- This happens after automatic medicine discharge
| Press Mist Button to reset Dispenser
NOTE: Device does not require maintenance by user.
¹Damage to the base can cause fire. Do not puncture base unit or expose to
xcessive heat (≥ 50° C), Li-Ion batteries may pose environmental and safety
hazards and should be disposed of in accordance with all applicable Federal
and State Law. Check with all governing travel bodies for current requirements
before air travel.
SPECIFICATIONS
Parameter | Specifications |
---|---|
Operating power | 4.1VDC |
Power source | Internally powered, Lithium-Ion Battery |
Instrument make / model | Eyenovia / Micro Dose Dispenser (MiDD) |
Dimensions | 50 length, 120mm height, 40mm width |
Weight (system) | < 100g |
Allowed operating temperature range | 15°C to 30°C |
Allowed shipping and storage temperature range | 15°C to 35°C at relative |
humidity of 15% to 90% RH, non-condensing
35°C to 60°C at water vapor pressure up to 50hPa
Allowed operation, storage, and shipping humidity range| 15°C to 30°C at
relative humidity of 15% to 90% RH, non- condensing
Allowed operation, storage, and shipping atmospheric pressure| 700hPa to
1060hPa
Electrical shock protection – Classification / Degree| Internally powered
Class I
Product life| 1 year
Battery life| 2-4 weeks, if used as indicated.
Shelf life| 12 months
Software version| Software version number can be found by calling the
manufacturer.
Charger Specifications (Micro-USB to USB Cable with Wall Plug):
Parameter | Specifications |
---|---|
Type | Switching Power Supply |
Input | 100-240V~, 50/60 Hz 200mA |
Output | 5V, 1A |
USB Cable Minimum Requirements | 5V, 1A |
Must be UL Listed. Must meet US Standard Level VI energy efficiency. Must meet
DOE & CEC regulatory requirements.
Example charging cable is UL number: E178074, Homespot Model S005AYU0500100
EMC COMPLIANCE
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and radiates radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experience radio/TV technician for help
Note: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Guidance and manufacturer’s declaration – electromagnetic emissions
The device is intended for use in the home healthcare environment in a
residential area (CISPR 11 Class B), as specified below. The customer or the
user of the device should assure that it is used in such an environment. The
safety of the device will be ensured, refer to section 2 (notes on safety).
Emissions Test| Compliance
RF emissions CISPR 11| Group 1
RF emissions CISPR 11| Class B
Harmonic Emissions IEC 61000-3-2| Class B
Voltage Fluctuations/Flicker emissions IEC 61000-3-3| Complies
Guidance and manufacturer’s declaration – electromagnetic immunity
The device is intended for use in the electromagnetic environment specified
below. The customer or the user of the device should assure that it is used in
such an environment.
Performance Criteria
Phenomena of a continuous nature.| Shall operate as intended.
Shall be no degradation of performance. Shall be no loss of function.
Phenomena of transient nature.| Functions shall be self-recoverable.
Shall operate as intended after recovering. Shall be no degradation of
performance,
Power interruption exceeding a certain time.| Functions shall be recoverable
by the operator. Shall operate as intended after recovering.
Shall be no degradation of performance.
Immunity Test| IEC 60601 Test Level| Compliance Level
Electrostatic fast transient/burst IEC 61000-4-4| ±2 kV for power supply lines
±1 kV for input/output lines
| ±2 kV for power supply lines
±1 kV for input/output lines
Surge IEC 61000-4-5 EN/IEC 61000-
4-3
| ±1 kV differential mode
±2 kV common mode
| ±1 kV differential mode
±2 kV common mode
Surge IEC 61000-4-5 EN/IEC 61000-
4-3
| Radiated Immunity
3 V/m, 80 – 2700 MHz
80% AM at 1 kHz & Proximity Fields from RF
Wireless Communications Equipment
| Radiated Immunity
3 V/m, 80 – 2700 MHz
80% AM at 1 kHz & Proximity Fields from RF
Wireless Communications Equipment
Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11
| Voltage Dips 30% reduction, 25/30 periods At 0°| Voltage Dips 30% reduction,
25/30 periods At 0°
Voltage Dips > 95% reduction, 0.5 period| Voltage Dips > 95% reduction, 0.5
period
| At 0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315°| At 0°, 45°, 90°, 135°,
180°, 225°, 270°, and 315°
Voltage Dips > 95 reduction, 1 period At 0°| Voltage Dips > 95 reduction, 1
period At 0°
Voltage Interruptions > 95% reduction, 250/300 periods| Voltage Interruptions
95% reduction, 250/300 periods
Immunity to RF Wireless Communications EquipmentTest Frequency (MHz)| Band a) (MHz)| Service a)| Modulation b)| Max. Power (W)| Distanc e (m)| Immunity test level (V/m)
385| 380 –390| TETRA 400| Pulse b) 18 Hz| 1.8| 0.3| 27
450| 430 – 470| GMRS 460, FRS 460| FM c) ± 5 kHz Deviation 1 kHz sine| 2| 0.3| 28
710| 704 – 787| LTE Band 13, 17| Pulse b) 217 Hz| 0.2| 0.3| 9
745
780
810| 800 – 960| GSM 800/900, TETRA 800,
iDEN 820,
CDMA 850, LTE
Band 5
| Pulse b) 18 Hz| 2| 0.3| 28
870
930
1720| 1 700 – 1 990| GSM 1800;
CDMA 1900;
GSM 1900; DECT; LTE Band 1, 3, 4, 25; UMTS
| Pulse b) 217 Hz| 2| 0.3| 28
1845
1970
2450| 2 400 – 2 570| Bluetooth, WLAN, 802.11 b/g/n, RFID 2450, LTE Band
7
| Pulse b) 217 Hz| 2| 0.3| 28
5240| 5 100 – 5 800| WLAN 802.11 a/n| Pulse b) 217 Hz| 0.2| 0.3| 9
5500
5785
a) For some services, only the uplink frequencies are included.
b) The carrier shall be modulated using a 50% duty cycle square wave signal.
c) As an alternative to FM modulation, 50% pulse modulation at 18 Hz may be used because, while it does not represent actual modulation, it would be worst case.
Bluetooth Module
Designation| Unit| Value
Transmit and receive frequencies| MHz| 2402-2480
Antenna(s) & Gain| dBi| Internal Antenna, Gain: 0.5dBi
Transmission power| mW| 0.79
Type of Modulation / Data Rate| –| GFSK / 1Mbit/s
Bluetooth FCC ID| –| 2A2VJ-EyenoviaGen1
Note: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation
Recommended separation distances between portable and mobile RF communications equipment and the device, except for the distances indicated in the following table “Immunity to RF Wireless Communications Equipment”.
The device is intended for use in an electromagnetic environment in which
radiated RF disturbances are controlled. The customer or the user of the
device can help prevent electromagnetic interference by maintaining a minimum
distance between portable and mobile RF communications equipment
(transmitters) and the device as recommended below, according to the maximum
output power of the communications equipment.
Rated maximum output power of transmitter (W)| Separation distance
according to frequency of transmitter (m)
150 kHz to 80 MHz d = 1.2√P| 80 MHz to 800 MHz d = 1.2√P| 800 MHz to 2.7 GHz d
= 2.3√P
0.01| 0.12| 0.12| 0.23
0.1| 0.38| 0.38| 0.73
1| 1.2| 1.2| 2.3
10| 3.8| 3.8| 7.3
100| 12| 12| 23
For transmitters rated at a maximum output power not listed above, the
recommended separation distance d in meters (m) can be estimated using the
equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the
transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separation
distance for the higher frequency range applies. NOTE 2 These guidelines may
not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
DISPOSAL
WARNING: Contains Lithium-Ion Battery:
Lithium-Ion Batteries may pose environmental and safety hazards and should
be disposed of in accordance with all applicable Federal and State law.
WARNING: Electronic Equipment:
Base Unit should be properly disposed of in accordance with all applicable State and Federal law.
REPORTING TO MANUFACTURER AND AUTHORITIES
If a serious incident occurs in connection with this medical device
affecting the operator or another person, the operator (or person responsible)
must report this serious incident to the manufacturer or seller of the medical
device
SYMBOLS USED IN LABELS ON THE MIDD BASE
SYMBOL | DEFINITION | SYMBOL | DEFINITION |
---|---|---|---|
**** | CAUTION, CONSULT ACCOMPANYING DOCUMENTS | **** | **** |
USE BY (YYYY-MM: YEAR-MONTH)
| SEE INSTRUCTIONS FOR USE| ****
| ELECTRONIC EQUIPMENT.
DO NOT THROW IN TRASH.
| CATALOG NUMBER| | NON-STERILE
| BATCH CODE| | KEEP DRY
| QUANTITY| | LITHIUM ION BATTERY – TO BE APPROPRIATELY RECYCLED
| DATE OF MANUFACTURE (YYYY-MM : YEAR-MONTH)| | MANUFACTURER
| WARNING: ELECTRICITY| | CAUTION: FEDERAL LAW RESTRICTS THIS
PRODUCT
MANUFACTURED BY
Eyenovia, Inc.
8748 Technology Way, Reno, NV 89521
© 2021 Eyenovia, Inc. All rights reserved.
Contact / Return goods policy:
Contact your sales representative or the manufacturer for RMA returns.
www.eyenovia.com; admin@eyenoviabio.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>