This manual explains the proper installation and use of your appliance, please read it carefully before using it even if you are familiar with the product. The manual should be kept in a safe place for future reference. In case of failure, only the Authorized Technical Service may repair this hob. Otherwise, the guarantee will be null and void.

Warning

General Safety

  • The appliance may only be installed and connected by licensed gasfitters / authorized persons.
  • Built-in appliances may only be used after they have been built in to suitable built-in units and work surfaces that meet local authority standards.
  • Repairs to the appliance must only be carried out by trained registered authorized service persons/engineers.
  • The technical and identification data for the hob is located on the reference data plate fixed to the underside of the appliance.
  • This reference data plate must be consulted before making the electrical connections.
  • The electrical connections must be made by specialist installers to the legal and regulatory, requirements in each country.
  • If the cable is damaged in any way it must be replaced by the manufacturer or after-sale service or by authorized technical staff, to avoid a hazard.
  • DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE.
  • DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
  • DO NOT MODIFY THIS APPLIANCE.
  • DO NOT USE THIS APPLIANCE AS A SPACE HEATER.

Correct Use

  • People (including children) who, because of their physical, sensory or mental capabilities or their inexperience or ignorance are not able to use the device safely, should not use this device without supervision or instruction by a responsible person.
  • This appliance should be used only for normal domestic cooking and frying of food.
  • The appliance must not be used as a work surface or as a storage surface.
  • Additions or modifications to the appliance are not permitted.
  • Do not place or store flammable liquids, highly inflammable materials, or fusible objects (e.g. plastic film, plastic, aluminum) on or near the appliance.
  • Do not heat an empty pan on the appliance.

Children’s Safety

  • The cooking zones will become hot when you cook. Therefore, always keep small children away from the appliance.
  • The appliance is not intended for use by young children or infirm persons without supervision.
  • Young children should be supervised to ensure that they do not play with the appliance.

Safety During Use

  • There is the risk of burns from the appliance if used carelessly.

  • Cables from electrical appliances must not touch the hot surface of the appliance or hot cookware.

  • Overheated fats and oils can ignite very quickly. Warning! Fire hazard!

  • Switch the cooking zones off after each use.

  • Users with implanted pacemakers should keep their upper body at least 30 cm from cooking zones that are switched on.

  • Risk of burns! Do not place objects made of metal, such as knives, forks, spoons, and saucepan lids on the cooking surface, as they can get hot.

  • Special conditions, which shall be avoided, e.g. marine environment, and any conditions necessary to ensure optimum performance.

  • The appliances can be used in freezing conditions.

Safety Instructions

Safety When Installation

  • DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE.

  • DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.

  • WHERE THIS APPLIANCE IS INSTALLED IN MARINE CRAFT OR CARAVANS, IT SHALL NOT BE USED AS A SPACE HEATER.

  • This hotplate must be installed in accordance with:
    AS/NZS5601 – Gas Installations (for Australia) – current edition
    NZS 5261 – Code of Practice for the Installation of Gas Burning Appliances and Equipment (for New Zealand) This standard may not be now current!!
    Local gas fitting regulations
    AS/NZS 3000 – Electrical Installations (Wiring Rules)
    Building codes
    Any other relevant statutory regulations.

  • Check the gas type label on the underside of the hotplate, adjacent to the gas connection to ensure it corresponds to the installation gas supply. If in doubt contact the supply authority.

  • The power supply cord (supplied) must not touch against any hot surfaces and must be placed so that its temperature does not exceed 75 degrees at any point along its length.

  • After connecting to gas, check for leaks using the soapy solution, never a naked flame.

  • Where a flexible hose assembly is used, ensure it is approved to AS/NZS 1869, Class B 10mm diameter and no more than 1.0metre in length. Any hose assembly used must be restrained from accidental contact with the flue outlet of an under-bench oven.

How To Avoid Damage To The Appliance

  • Do not use the cooking zones with empty cookware or without cookware.
  • The ventilation gap of 5mm between the worktop and front of the unit underneath it must not be covered.
  • DO NOT MODIFY THIS APPLIANCE.

Safety When Cleaning

  • For cleaning, the appliance must be switched off and cooled down.
  • For safety reasons, the cleaning of the appliance with steam jet or high-pressure cleaning equipment is not permitted.

Disposing of The Device
When disposing of the device, do not bring it to regular municipal waste containers. Instead, bring it to electrical and electronic waste recycling and reuse center. A relevant label has been put on the device, its instructions manual, or the package. The device has been manufactured of recyclable material. By bringing the old devices to a recycling collection center, you show that you care about nature. Ask your local environmental care authority for information on the location of such facilities.
Gas type label nearby the gas inlet, black color for natural gas, signal red color for ULPG:
Natural Gas
Refer to the gas supplier if supply in doubt
Universal LPGas
Refer to a gas supplier if supply in doubt

Product Description

eurotech ED GC604SS 60cm Gas Cooktop - Product
Description

No.| Model| **Burner*| FSD| Pan supports| Knob position| Total gas consumption| Over view**
---|---|---|---|---|---|---|---
1| ED-GC6O4SS| 1W+2SR+1 A| With| 2 types for option| Front| LPG: 30.5M3/h|
NG: 29.5M3/h
2| ED-GC705SS| 1W+1R +2SR+1A| With| 2 types for
option| Front| LPG: 39.6M3/h|
NG:
39.01%13/h
3| ED-GC905SS| 1W+1R +2SR+1A| With| 2 types for
option| Front| LPG: 39.6M3/h|
NG:
39.01%13/h

*Note:
For burner: W=Triple Ring Wok burner, R=Rapid burner, SR=Semi-Rapid burner, A=Auxiliary burner

Accessory Name| Picture ( for reference only, the physical unit may be different)| Quantity
---|---|---
User Manual| | 1
Sealing tape| | 1 roll
Additional labels| You have an additional rating label in the accessory bag, suggest attaching it onto a surface where it can be read e.g. inside the surface of an adjacent cupboard| 1 set
Installation clip| eurotech ED GC604SS 60cm Gas Cooktop - Over view
3| 4 sets
Screws ST4.2×24| | 4 pcs
LPG Injectors| | 4 pcs
Elbow &Washers| | 1 Elbow, 3 washers

Technical Specifications

Model| Product Dimensions
(h x w x d) mm| Cut-out Size
( w x d)mm| App’x net weight| Electrical Connection| Rated Input Power
---|---|---|---|---|---
ED-GC604SS| 85x580x500| 552 x 470| 12.5Kgs| 220-240V/50Hz| 0.5W
ED-GC705SS| 85x680x500| 552 x 470| 15.7Kgs| 220-240V/50Hz| 0.5W
ED-GC905SS| 85x860x500| 827 x 470| 18.7Kgs| 220-240V/50Hz| 0.5W

Installation

Before Installation:

  • Before cutting into any benchtops, ensure the minimum clearances to walls, adjacent surfaces and overhead surfaces required by the relevant gas appliance installation code (see above) will comply.
    Dimensions are specified in millimeters (mm)
    Overhead cupboards and range hood = 650 mm.
    Side and rear clearance = 200 mm to any burner edge.
    Overhead exhaust/ceiling fan = 750 mm
    Horizontal surfaces adjacent to the hob = less than or equal to the hob height.
    Ensure there is sufficient clearance to fit the regulator and/or flexible hose connection with the hotplate in the installed position.
    Before the appliance is installed into the cabinet, please make sure any transit protection is removed.

When you have installed the hob, make sure that

  • The GPO (general purpose outlet) must always be in an accessible position.
  • The supply connection point, test point, and natural gas regulator adjustment screw (for Natural gas installation) are accessible for testing and/or adjustment with the hotplate in the installed position.

TO BE INSTALLED ONLY BY AN AUTHORIZED PERSON.

  1. Cupboard Cutting
    Benchtop thickness, 30– 40 mm (3 – 4 cm).
    eurotech ED GC604SS 60cm Gas Cooktop - Cupboard
Cutting

  2. Place Burner Box
    Apply the adhesive sealing tape to the underside lip of the burner box. Shown at G opposite.
    Place burner box into cutout hole and fit clamping brackets to clamp the hotplate to the bench.
    eurotech ED GC604SS 60cm Gas Cooktop - Place Burner
Box

  3. Fit Burners And Trivet.
    Replace burners and ensure they are correctly repositioned over the ignitor (S) and thermocouple (T). The ignitor (S) must be clean for trouble-free sparking. Test burner ignition and burner flame for correct operation, If the burner is placed correctly it will not rotate on its supports.
    The Triple Ring (Wok) burner (diagrams below) does not fit over the igniter or thermocouple but must be placed on its supports. Make sure trivet is fitted onto its locator on burners and can’t rotate after assembly.
    eurotech ED GC604SS 60cm Gas Cooktop - Fit Burners And
Trivet

  4. Electrical Connection
    Install a 10 amp general purpose outlet (GPO) in accordance with relevant electrical standards and/or codes of practice applicable.
    The power supply cord (supplied) must not touch against any hot surfaces and must be placed so that its temperature does not exceed 75℃ at any point along its length.
    After having installed the hotplate, the GPO must always be in an accessible position.
    eurotech ED GC604SS 60cm Gas Cooktop -Electrical
Connection Wiring diagram(Applicable to model: ED-GC604SS) (ED-GC705SS, ED-GC905SS)
    eurotech ED GC604SS 60cm Gas Cooktop - Wiring diagram

  5. Gas Connection (OPTIONAL)
    Install in accordance with relevant gas standards and/or codes of practice applicable.
    Connect the elbow fitting to the appliance gas manifold connection, and check that seals between the elbow and manifold connection are in place and in good condition.
    • For Natural gas: connect the natural gas appliance regulator (pictured opposite) with an integral test point using approved gas thread tape or compound to the elbow fitting.
    • For Universal LPG: see page 12
    Ensure the supply connection point, test point, and natural gas regulator adjustment screw (for Natural gas installation) are accessible for testing and/or adjustment with the hotplate in the installed position.
    eurotech ED GC604SS 60cm Gas Cooktop - Gas Connection
1Where a flexible hose assembly is used, ensure it is approved to AS/NZS 1869, Class B. Any hose assembly used must be restrained from accidental contact with the flue outlet of an under- bench oven. This hose assembly shall be suitable for connection to a fixed consumer piping outlet located as follows:
    Hotplates at a point 800 mm to 850 mm above the floor and in the region outside the width of the appliance to a distance of 250 mm.
    After connecting to gas, check for leaks using the soapy solution, never a naked flame.
    Inlet connection region for flexible hose
    Fit the duplicate data plate (supplied in a separate bag) on a surface adjacent to the hotplate, for example, the inside of the cupboard door so it is clearly visible for any service technician.
    SETTING THE GAS PRESSURE:
    Fit a manometer with a 6 mm rubber hose to the test point on the regulator (for natural gas).
    Light Triple Ring and Auxiliary burner on and adjust test point pressure to 1.00 kPa. Turn the two burners off and on again and recheck the pressure is the same asset previously or adjust as required.
    TEST FOR CORRECT OPERATION:
    After installation and adjusting burner pressure using test point, each burner ignition and operation must be tested individually and with all burners operating. This testing must be done by the installer before leaving.

Natural Gas (the appliance test point is located at the regulator)
The supplied regulator must be fitted to the appliance inlet connection. Gas pressure must be adjusted to 1.0 kPa when approximately 50% of the burners are on high flame.
eurotech ED GC604SS 60cm Gas Cooktop - natural gas

  1. Test point location
  2. Gas inlet pipe
  3. Elbow
  4. Regulator

Universal LPG (the appliance test point is located at the injector)
Gas pressure must be checked to confirm the appliance operating pressure is 2.75 kPa, the appliance test point is the rapid burner injector as shown below.

  1. Disconnect power.
  2. Light the auxiliary burner and set it to a high flame. Ensure all other burners are off.
  3. Zero manometers, then apply flexible tubing to seal over the Rapid burner injector, hold securely in place and check the gas pressure by pressing in the corresponding burner control knob, then turning to the high flame position.
  4. If the pressure is 2.75 kPa, reassemble the burner and perform the final checks as per this instruction manual.
  5. If the pressure is not 2.75 kPa, disconnect the appliance and check/adjust/replace the LPG cylinder regulator(s) as appropriate in accordance with AS/NZS 5601
    Patent 2015101170. For enquires contact Gas Approval Consulting Pty Ltd Tinon license 036 for SAI-400193

eurotech ED GC604SS 60cm Gas Cooktop - universel Alternative: If the appliance is supplied with an LPG test point adapter; then this component may be fitted to the inlet connection for the purpose of a test point.

ADJUSTING THE BURNER MINIMUM FLAME HEIGHT:
NOTE: This adjustment can only be performed by the installer or authorized service personnel.
The minimum burner flame is factory adjusted for the gas type stated on the gas type label adjacent to the gas connection and should not require adjustment. Adjustment may be required if the hotplate has been converted from Natural gas to Universal LPG or vice versa.
GAS CONVERSION INSTRUCTIONS:
The manufacturers servicing instructions detail how authorized personnel may convert the hotplate from Natural gas to Universal LPG or from Universal LPG to Natural gas. Contact the manufacturer or agent as required.
For model ED-GC604SS

ADJUSTED FOR NATURAL GAS 1.0kPa

NOZZLES
DIAMETER| mm| Gas consumption,
MTh
WOK| 1.70| 13.0
Rapid| 1.40| 10.
SEMI RAPID| 1.10| 6.0
AUXILIARY| 0.90| 5.
Replacement of the nozzles must be performed by a qualified person. Once the nozzles have been replaced this label must be affixed to the nameplate of the appliances.
Natural Gas regulator is to be fitted and adjusted
ADJUSTED FOR ULPG 2.75KPa

NOZZLES DIAMETER| mm| Gas consumption, MJ/h
WOK| 0.98| 13.0
Rapid| 0.90| 10.0
SEMI RAPID| 0.7| 7.
AUXILIARY| 0.55| 4.0
Replacement of the nozzles must be performed by a qualified person. Once the nozzles have been replaced this label must be affixed to the name plate of the appliances.
Change the NG regulator to LPG by a qualified person.

For model ED-GC705SS, ED-GC905SS

ADJUSTED FOR NATURAL GAS 1.0kPa

NOZZLES DIAMETER| mm| Gas consumption, MJ/h
WOK| 1.7| 13.0
Rapid| 1.4| 10.0
SEMI RAPID| 1.1| 6.0
AUXILIARY| 0.9| 4.0
Replacement of the nozzles must be performed by a qualified person. Once the nozzles have been replaced
this label must to be affixed to the nameplate of the appliances.
Natural Gas regulator is to be fitted and adjusted
ADJUSTED FOR ULPG 2.75KPa

NOZZLES DIAMETER| mm| Gas consumption,
WOK| 0.98| 13.0
Rapid| 0.9| 10.0
SEMI RAPID| 0.7| 6.3
AUXILIARY| 0.55| 4.0
Replacement of the nozzles must be performed by a qualified person. Once the nozzles have been replaced this label must to be affixed to the nameplate of the appliances.
Change the NG regulator to LPG by a qualified person.

Start Using Your Appliance

ED-GC604SS
eurotech ED GC604SS 60cm Gas Cooktop - Start Using Your
Appliance ED-GC705SS, ED-GC905SS

eurotech ED GC604SS 60cm Gas Cooktop - Start Using Your Appliance
1

Description Explanation
Zone indicators These show which zone is under control.
Flame power The flame power of the zones is the lowest and is the highest.

The hotplates are fitted with mains-powered electronic spark ignitors, so must be connected to mains power supply (i.e. nominal 220~240 V ac) to operate. If power is not available, the hotplate will still work but the burners will have to be lit with a match or similar.
Depressing the gas control knob of any burner will activate the spark ignition for all burners. To light the burner, turn the gas control knob to the High Flame setting of the burner to be lit, while at the same time depressing the gas control knob to activate the spark ignition.
Once the burner is alight continue to depress the gas control knob for 5 – 10 seconds to allow the flame safeguard to activate. If when you release the gas control knob, the burner flame goes out the flame safeguard has not heated up enough so repeat the ignition procedure after waiting 1 minute for gas to disperse. If problems with burner lighting persist, refer to the TROUBLESHOOTING section of these instructions.
If power is not available, light a match or similar, then turn the gas control knob for the burner to be lit, to the High Flame setting. Once again if problems with burner lighting persist, refer to the TROUBLESHOOTING section of these instructions.
When burner lights, adjust the desired flame height. On finishing, turn the control knob to the off position marked with a black DOT.

BURNER AND UTENSIL CHOICE

The maximum utensil (pan) diameters in millimeters (mm) for each burner are:

  1. For Natural Gas hotplates
    Auxiliary (small) and Semi-Rapid (medium) = 195 mm
    Rapid (large) = 230 mm
    Triple ring (wok) = 270 mm

  2. For Universal LPG hotplates
    Auxiliary (small), Semi-Rapid (medium) and Rapid (large) = 195 mm
    Triple ring (wok) = 230 mm

The minimum utensil (pan) diameters in millimeters (mm) for each burner are:
Auxiliary (small) = 80 mm
and Semi-Rapid (medium) = 140 mm
Rapid (large) and Triple ring (wok) = 195 mm or best efficiency and to ensure utensil handle does not overheat, place the utensil centrally on the burner and adjust the flame height so all the flame remains under the utensil.

Maintenance & Troubleshooting

Cleaning and maintenance should be carried out with the appliance cold especially when cleaning the enameled parts. Avoid leaving alkaline or acid substances(lemon juice, vinegar, etc.) on the surfaces.

STAINLESS STEEL
The stainless steel hob of the hotplate must be cleaned regularly (e.g. weekly) to ensure the long life expectancy of the hotplate.
Ensure the hotplate has cooled. Wash down with warm soapy water and rinse with clean water.
Dry with a clean soft cloth. A specialized stainless steel cleaning fluid may be used.
NOTE: Ensure that wiping is done along with the grain of the stainless steel to prevent any unsightly crisscross scratching patterns from appearing.

TRIVETS (UTENSIL SUPPORTS)
Enameled parts must only be washed with a sponge and soapy water or with non- abrasive products. Rinse with clean water. Dry with a clean soft cloth.

BURNERS
Remove trivets from the hob. Ensure burners are cool. Remove the burner’s enameled cap (C) and aluminum burner crown (F). Wash down with warm soapy water and rinse with clean water. Dry with a clean soft cloth.

eurotech ED GC604SS 60cm Gas Cooktop - BURNERS

Use a cotton bud, toothbrush, or some other item to clean out any incrustations or dirt from the four holes marked(H)

eurotech ED GC604SS 60cm Gas Cooktop - BURNERS 1

Replace burners and ensure they are correctly repositioned over the igniter (S) and thermocouple (T). The igniter (S) must be clean for trouble-free sparking. Test burner ignition and burner flame for correct operation.
The Triple Ring (Wok) burner (diagrams below) does not fit over the igniter or thermocouple but must be placed on its supports. If the burner is placed correctly it will not rotate on its supports.

eurotech ED GC604SS 60cm Gas Cooktop - BURNERS 2

(b) removal of components for service—(ii) pilot and flame safeguard;
(iii) ignition system;
(v) gas control;
(vii) hotplate top;
(ix) thermocouple;
(c) parts replacement—
(iv) electronic ignition;
(d) adjustments—
(iv) ignition (spark gap);

TROUBLESHOOTING

Servicing of the hotplates must only be done by an authorized service representative (see back of this booklet) and the hotplate must not be modified. Power must be disconnected before any servicing or maintenance is conducted.
DO NOT MODIFY THIS APPLIANCE.
It is recommended the hotplate be serviced by an authorized person at least every 2 years. This service is not covered by warranty.
Abnormal conditions include:

  • Excessively yellow or sooting flame type.
  • Flame lifting off the burner ports.
  • Flame lighting back into the burner (normally associated with a popping sound).
  • The objectionable odor of the flames combustion products.

Should a faulty condition develop in the hotplate that is not described above, refer to the following table first for possible causes and remedies prior to contacting an authorized service representative. Servicing beyond the remedies listed shall only be undertaken by an authorized service representative.

FAULT POSSIBLE CAUSE REMEDY
No spark when gas control knob depressed. No power. Check plugged in and

switched on. Check the mains circuit breaker.
Loose sparker cable.| Call authorised representative.
Burner not aligned properly.| Remove and re-fit burner.
Burner not lighting when spark ignition working.| Gas supply off.| Check gas supply valve on.
Burner is not aligned properly.| Remove and re-fit burner.
Burner ports blocked.| Remove, clean and replace burner.
Burner goes out when
the control knob is released.| Flame safeguard not activated.| Re-light, allow more time for flame safeguard to activate.
Flame safeguards faulty connection or broken.| Call authorised representative.
Uneven flame pattern or slight flame lifting.| Burner ports blocked.| Remove, clean and replace burner.
At minimum flame setting the flame is too high.| Turndown control setting incorrect.| Call authorised representative.
Small flame on High
setting.| The regulator is faulty.| Call authorised representative.
Gas supply pressure is low.| Call authorised representative.
Incorrect injector fitted.| Call authorised representative.
Blocked injector or gas supply tube.| Call authorised representative.
Incorrect utensil size.| Refer to operating instructions utensil choice.
Flame too high on High setting.| The regulator is faulty.| Call authorised representative.
Incorrect injector fitted.| Call authorised representative.
Incorrect utensil size.| Refer to operating instructions utensil choice.