KNOW ABOUT THIS RADIO

KNOW ABOUT THIS RADIO

1 Squelch control, SQ, ASQ switch key
2 Mode/Scan key
3 RF Gain control
4 CH9/CH19/Keypad lock
5 Power On/Off Volume control
6 LCD
7 External speaker Jack
8 Antenna Jack

HOW TO USE THIS RADIO

Power On/Off the radio

  1. Turn VOL switch clockwise to power on the radio, the LCD displays the Norms and then displays channel number.
  2. Turn VOL switch anti-clockwise, until hear Ka Ta, the radio is powered off.

Volume Control
Turn clockwise to increase volume, anti-clockwise to decrease volume.

Channel Control

  1. Short press [ UP ] or [ DN ] to change working channel.
  2. Hold [ UP ] or [ DN ] can fast change working channel.

Squelch Level Control (O.F to 2.8 level available)

  1. Short press SQ , until LCD displays SQ and then displays X.X, X.X stands for SQ level, the bigger value stands for high squelch level.
  2. Short press [ UP ] or [ DN ] to change SQ level.
  3. Hold [ UP ] or [ DN ] can fast change SQ level.
  4. Hold SQ or wait for 3 seconds to store and exit.

ASQ Control(A.1-A.9 level available)

  1. Hold SQ key, until LCD displays AQ, the ASQ function turned on. The LCD will displays “A.X”, “X” stands for the ASQ level.
  2. Short press microphone [ UP ] or [ DN ] to change SQ level
  3. Hold microphone [ UP ] or [ DN ] can fast change ASQ level.
  4. Hold  SQ or wait for 3 seconds to store and exit.

Mode Control

  1. Short press A/F key to switch between AM /FM mode.
  2. The LCD displays the selected mode.

RF Gain Control

  1. Short press key RFG , LCD displays R and the present RF gain level flashes.
  2. Short press microphone [ UP ] or [ DN ] to change level.
  3. Short press RFG key to exit RF gain level control.

Note:  When RFG function is on, the LCD displays R. If RFG level is 6 means the attenuation is 6dBm.

Emergency Channel

  1. Short press key to choose CH9, the channel number flashes.
  2. Short press key again to choose CH19, the channel number flashes.
  3. Short press key third time to return to last normal channel.

Keypad Lock

  1. Hold key for over 2 seconds to lock the keys, LCD displays “LC”.
  2. Hold key for over 2 seconds again to unlock the keys, LCD displays OF.

Note: In lock Mode all keys except PTT is valid.

Scan Function

  1. Hold to start scan function, “SC” falshes in the LCD;
  2. Press [ UP ] or [ DN ] to change scan direction during scan;
  3. Press or [PTT] key to exit scan function.

Band Control

  1. Hold to power on radio, until LCD displays the bands;
  2. Press [ UP ] or [ DN ] to choose wanted bands;
  3. Power off and power on again.

High/Low Control

  1. Hold and PTT key to power on;
  2. Press [ UP ] or [ DN ] to choose wanted power level, PH is 8W, PL is 4W;
  3. Power off and power on again.

Install External Speaker
Choose a 8Ω external speaker with 3.5mm mono connector.

Resume Factory Default

  1. Hold SQ key to power on radio, until the LCD displays “RT”.
  2. All channel and function setting will resume factory default after above operation.

SPECIFICATION

GENERAL

Modulation Mode| AM/FM
Frequency Range| 28.000-29.700MHz
Frequency Tolerance| ±5.0ppm
Input Voltage| 13.2V
Dimensions| 109x104x25mm
Weight| 421g
Ferquency Control| PLL Synthesizer
Operating Temperature Range| -20℃ ~ +50℃
Current Drain| Transmit| 2A MAX
Receive| Squelched 0.3A
VOL Max| 0.8A
Antenna Connector| UHF,SO-239
TRANSMITTER
Power Output| 8 Watts FM/AM
Transmission interference| inferior to 4nW(-54dBm)
Frequency Response| 300-3000Hz
Modulated signal distortion| inferior to 5%
Output Impedance| 50 ohms
RECEIVER
Sensitivity| Less than 1uV for 10dB(S+N)/N
Image Rejection| 70dB
Adjacent Channel Rejection| 60dB
IF Frequencies| 1st 10.695MHz
2nd 455KHz
Automatic Gain Control(AGC)| Less than 10dB change in audio
Output for inputs from 10 to 50000uV
Squelch| less than 1uV
Audio Output Power| 1Watts
Frequency Response| 300-3000Hz

FREQUENCIES TABLE

BAND ID HA HB HC HD HE HF HG HH HI
CH-01 28.000 28.200 28.400 28.600 28.800 29.000 29.200 29.400 29.600
CH-02 28.005 28.205 28.405 28.605 28.805 29.005 29.205 29.405 29.605
CH-03 28.010 28.210 28.410 28.610 28.810 29.010 29.210 29.410 29.610
CH-04 28.015 28.215 28.415 28.615 28.815 29.015 29.215 29.415 29.615
CH-05 28.020 28.220 28.420 28.620 28.820 29.020 29.220 29.420 29.620
CH-06 28.025 28.225 28.425 28.625 28.825 29.025 29.225 29.425 29.625
CH-07 28.030 28.230 28.430 28.630 28.830 29.030 29.230 29.430 29.630
CH-08 28.035 28.235 28.435 28.635 28.835 29.035 29.235 29.435 29.635
CH-09 28.040 28.240 28.440 28.640 28.840 29.040 29.240 29.440 29.640
CH-10 28.045 28.245 28.445 28.645 28.845 29.045 29.245 29.445 29.645
CH-11 28.050 28.250 28.450 28.650 28.850 29.050 29.250 29.450 29.650
CH-12 28.055 28.255 28.455 28.655 28.855 29.055 29.255 29.455 29.655
CH-13 28.060 28.260 28.460 28.660 28.860 29.060 29.260 29.460 29.660
CH-14 28.065 28.265 28.465 28.665 28.865 29.065 29.265 29.465 29.665
CH-15 28.070 28.270 28.470 28.670 28.870 29.070 29.270 29.470 29.670
CH-16 28.075 28.275 28.475 28.675 28.875 29.075 29.275 29.475 29.675
CH-17 28.080 28.280 28.480 28.680 28.880 29.080 29.280 29.480 29.680
CH-18 28.085 28.285 28.485 28.685 28.885 29.085 29.285 29.485 29.685
CH-19 28.090 28.290 28.490 28.690 28.890 29.090 29.290 29.490 29.690
CH-20 28.095 28.295 28.495 28.695 28.895 29.095 29.295 29.495 29.695
CH-21 28.100 28.300 28.500 28.700 28.900 29.100 29.300 29.500
CH-22 28.105 28.305 28.505 28.705 28.905 29.105 29.305 29.505
CH-23 28.110 28.310 28.510 28.710 28.910 29.110 29.310 29.510
CH-24 28.115 28.315 28.515 28.715 28.915 29.115 29.315 29.515
CH-25 28.120 28.320 28.520 28.720 28.920 29.120 29.320 29.520
CH-26 28.125 28.325 28.525 28.725 28.925 29.125 29.325 29.525
CH-27 28.130 28.330 28.530 28.730 28.930 29.130 29.330 29.530
CH-28 28.135 28.335 28.535 28.735 28.935 29.135 29.335 29.535
CH-29 28.140 28.340 28.540 28.740 28.940 29.140 29.340 29.540
CH-30 28.145 28.345 28.545 28.745 28.945 29.145 29.345 29.545
CH-31 28.150 28.350 28.550 28.750 28.950 29.150 29.350 29.550
CH-32 28.155 28.355 28.555 28.755 28.955 29.155 29.355 29.555
CH-33 28.160 28.360 28.560 28.760 28.960 29.160 29.360 29.560
CH-34 28.165 28.365 28.565 28.765 28.965 29.165 29.365 29.565
CH-35 28.170 28.370 28.570 28.770 28.970 29.170 29.370 29.570
CH-36 28.175 28.375 28.575 28.775 28.975 29.175 29.375 29.575
CH-37 28.180 28.380 28.580 28.780 28.980 29.180 29.380 29.580
CH-38 28.185 28.385 28.585 28.785 28.985 29.185 29.385 29.585
CH-39 28.190 28.390 28.590 28.790 28.990 29.190 29.390 29.590
CH-40 28.195 28.395 28.595 28.795 28.995 29.195 29.395 29.595

WARNING Our Qixiang Electron Science & Technology Co.,Ltd radio generators RF electromagnetic energy during transmit mode. This radio is designed for and classified as“Occupational Use Only”,meaning it must be used only during the  course of employment by individuals aware of the hazards, and the ways To Minimize Such hazards.

This radio is NOT intended for use by the“General Population” in an uncontrolled environment. This radio has been tested and complies with the FCC RF exposure limits for“Occupational Use Only”.

In addition, our Qixiang Electron Science & Technology Co.,Ltd radio complies with the following Standards and Guidelines with regard to RF energy and electromagnetic energy levels and evaluation of such levels for exposure to humans:

  • IEEE Std. 1528:2013 and KDB447498, Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields.
  • American National Standards Institute (C95.1-1992), IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz.
  • American National Standards Institute (C95.3-1992), IEEE Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields-RF and Microwave.

CAUTION The information listed above provides the user with the information needed to make him or her aware of RF exposure, and what to do to as-sure that this radio operates with the FCC RF exposure limits of this radio.

Electromagnetic Interference/Compatibility
During transmissions, Qixiang Electron Science & Technology Co.,Ltd radio generates RF energy that can possibly cause interference with other devices or systems. To avoid such interference, turn off the radio in areas where signs are posted to do so. DO NOT operate the transmitter in areas that are sensitive to electromagnetic radiation such as hospitals, aircraft, and blasting sites.

Occupational/Controlled Use
The radio transmitter is used in situations in which persons are exposed as consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help

MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AnyTone User Manuals

Related Manuals