AnyTone SMT02 Smart SB Radio Instruction Manual

June 6, 2024
AnyTone

AnyTone SMT02 Smart SB Radio Instruction

KNOW ABOUT THIS RADIO

  1. Squelch control, SQ, ASQ switch key
  2. Mode/Scan key
  3. RF Gain control
  4. CH9/CH19/Keypad lock/VOX control/VOX setting
  5. Power On/Off Volume control
  6. LCD
  7. External speaker jack
  8. Antenna Jack

Note: To get the best range from the external whip antenna (50 ) should be used. Ω Ant : Tx/ Rx 26.965-27.405Mhz ,0 dBi nominal (3dBi Max)

HOW TO USE THIS RADIO

  1. Power On/Off the Radio
  2. Turn VOL switch clockwise to power on the radio, the LCD displays the Norms and then displays channel number.
  3. Turn VOL switch anti-clockwise, until hearing Ka Ta, the radio is powered off.
  4. Volume control
  5. Turn clockwise to increase volume, anti-clockwise to decrease volume.
  6. Channel Control.
  7. Short press microphone [ UP ] or [ DN ] to change the working channel.
  8.  Hold microphone [ UP ] or [ DN ] can fast change the working channel.
  9. Squelch level control(O.F to 3.4 level available)
  10.  Short press, until LCD displays SQ and then displays X.X, X.X  stands for SQ level, the bigger value stands for high squelch level.
  11. Short press [ UP ] or [ DN ] to change SQ level.
  12. Hold [ UP ] or [ DN ] can fast change SQ level.
  13. Short press or wait for 3 seconds to store and exit.
  14. Note: The» higher» SQ» level» selected,» the» stronger» signal» required» to» open» speaker» and» hear» the» calling.
  15. ASQ control(A.1-A.9 level available)
  16. Hold key, until LCD displays AQ, the ASQ function turned on. The LCD will display “A.X”, “X” stands for the ASQ level, the bigger value stands for the high squelch level.
  17. Short press microphone [ UP ] or [ DN ] to change ASQ level
  18. Hold microphone [ UP ] or [ DN ] can fast change ASQ level.
  19.  Short press or wait for 3 seconds to store and exit.
  20. Note: The» higher» ASQ» level» selected,» the» stronger» signal» required» to» open» speaker» and» hear» the» calling.
  21. Mode control
  22.  Short press key to switch between AM /FM mode.
  23.  The LCD displays the selected mode.
  24. RF Gain control
  25.  Short press key, LCD displays RFG, and the present RF gain level flashes.
  26. Short press microphone [ UP ] or [ DN ] to change level.
  27. Short press [PTT] switch to exit RF gain level control.
  28. Note: The» higher» ASQ» level» selected,» the» stronger» signal» required» to» open» speaker» and» hear» the» calling.
  29. Emergency Channel
  30. 1. Short press key to choose CH9, the channel number flashes.
  31. Short press key again to choose CH19, the channel number flashes.
  32. Short press key third time to return to last normal channel.
  33. Keypad Lock
  34. Hold key for over 3 seconds to lock the keys, LCD displays ” “.
  35. Hold key for over 3 seconds again to unlock the keys, ” ” disappears from LCD.
  36. Note: The» higher» ASQ» level» selected,» the» stronger» signal» required» to» open» speaker» and» hear» the» calling.
  37. VOX control
  38. Press and hold [PTT] switch;
  39. Short press the key to activate or deactivate the VOX function. ” ” is displayed when the function is active.
  40. Note: The» higher» ASQ» level» selected,» the» stronger» signal» required» to» open» speaker» and» hear» the» calling.
  41. VOX Setting
  42.  Turn on the power while pressing the key enter the VOX function setting. ” ” flashes in the LCD.
  43. Short press key to choose a wanted setting.
  44. LX stands for sensitivity level. allows the adjustment of the microphone for optimum transmission quality. Adjustable level form 1 (high sensibility) to 9 (low sensibility)
  45. tX stands for delay time. allows avoiding the sudden cut of the transmission by adding a delay at the end of speaking. The level is adjustable form 1 (short time delay) to 9 (long time delay)
  46. Short press microphone [ UP ] or [ DN ] to set the desired level.
  47.  Hold key to store and exit setting.
  48. Scan function
  49. Hold to start scan function, “SC” flashes in the LCD;
  50.  Press microphone [ UP ] or [ DN ] to change scan direction during the scan;
  51. Hold or short press [PTT] switch to exit scan function.
  52. Norms control
  53. Hold to power on radio, until LCD displays the norms;
  54. Press microphone [ UP ] or [ DN ] to choose wanted norms;
  55.  Power off and power on again.
  56. Install external speaker
  57. Choose a 16Ω external speaker with a 3.5mm mono connector.
  58. Resume factory default
  59. Hold key to power on radio, until the LCD displays “rt”, the resume work finish.
  60.  All channel and function settings will resume factory default after the above operation.

SPECIFICATION

GENERAL

Modulation Mode| AM
Frequency Range| 26.965-27.405MHz
Frequency Tolerance| ±5.0ppm
Input Voltage| 12V
Dimensions| 140×161.5x41mm
Weight| 608g
Operating Temperature Range| -20℃ to +50℃

Current Drain

| Transmit| 3A MAX
Receive| Squelched 0.3A
VOL Max| 0.7A
Antenna Connector| UHF, SO-239
TRANSMITTER
Power Output| 4 Watts AM
Transmission interference| inferior to 4nW
Frequency Response| 300-3000Hz
Modulated signal distortion| inferior to 5%
Output Impedance| 50 ohms
RECEIVER
Sensitivity| Less than 1uV for 10dB(S+N)/N
Image Rejection| 70dB
Adjacent Channel Rejection| 60dB

IF Frequencies

| 1st 10.695MHz
2nd 455KHz

Automatic Gain Control(AGC)

| Less than 10dB change in audio
Output for inputs from 10 to 50000uV
Squelch| less than 1uV
Audio Output Power| 1Watts at 8Ω less than 10% distortion
Frequency Response| 300-3000Hz

FCC STATEMENT

Federal Communications Commission (FCC) Statement. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and 
  2. This device must accept any interference received,

including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Warning: Changes or modifications made to this device not expressly approved by Beijing Supvan Information Technology Co., Ltd may void the FCC authorization to operate this device.Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.

RF exposure statement: The transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated without restriction.

Licensing Information: Using our radio in the USA is subject to the rules & regulations of the FCC. Changes or modifications not expressly approved by our may void the user authority granted by the FCC to operate this radio and should not be made. To comply with FCC requirements, transmitter adjustments should be made only by or under the supervision of a person certified as technically qualified to perform transmitter maintenance and repairs in the private land mobile and fixed services as certified by an organization representative of the user of those services. Replacement of any transmitter component (crystal, semiconductor, etc) not authorized by the FCC equipment authorization for this radio could violate FCC rules.
Note: The use of this radio outside the country where it was intended to be distributed is subject to government regulations and may be prohibited.
Important: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this device. Your radio is set up to transmit a regulated signal at an assigned frequency. It is against the law to alter or adjust the settings inside the radio to exceed those limitations. Any adjustments to your radio must be made by qualified technicians.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AnyTone User Manuals

Related Manuals