LACOUSTICS LS10 Avnu Certified AVB Switch Owner’s Manual
- June 6, 2024
- LACOUSTICS
Table of Contents
LS10 Avnu Certified AVB Switch
LS10
owner’s manual (EN)
Document reference: LS10 owner’s manual (EN) version 2.2 Distribution date: June 23, 2021 © 2021 L-Acoustics. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means without the express written consent of the publisher.
Contents
Safety……………………………………………………………………………………………………………………………………………. 5 Important
safety instructions……………………………………………………………………………………………………….. 5
Introduction…………………………………………………………………………………………………………………………………….. 7 LS10 AVB
switch…………………………………………………………………………………………………………………….. 7 How to use this
manual……………………………………………………………………………………………………………. 7
Symbols…………………………………………………………………………………………………………………………8 Revision
history………………………………………………………………………………………………………………………..8
System components……………………………………………………………………………………………………………………………9
Cables………………………………………………………………………………………………………………………………….. 9 Rigging
elements………………………………………………………………………………………………………………………9
Technical description……………………………………………………………………………………………………………………….. 10 Main
features……………………………………………………………………………………………………………………….. 10
Components………………………………………………………………………………………………………………….10 Front and rear
panels……………………………………………………………………………………………………..11 Ethernet
ports……………………………………………………………………………………………………………………….. 11 Power
supply…………………………………………………………………………………………………………………………11
Inspection and preventive maintenance………………………………………………………………………………………………… 12
How to do preventive maintenance……………………………………………………………………………………………. 12 CHK –
External structure……………………………………………………………………………………………………………12 CHK – External
cleanness………………………………………………………………………………………………………….12 CHK – Network
functionalities and rmware…………………………………………………………………………………. 13
Installation…………………………………………………………………………………………………………………………………….. 14
Mounting………………………………………………………………………………………………………………………………14
Ventilation……………………………………………………………………………………………………………………………. 16 General Purpose
Output (GPO)………………………………………………………………………………………………….16 24 V DC Input and
Output……………………………………………………………………………………………………….17 Network
cabling……………………………………………………………………………………………………………………. 19 Connection
panels………………………………………………………………………………………………………….19 Cabling
examples…………………………………………………………………………………………………………. 20 Connecting to AC
mains…………………………………………………………………………………………………………. 23 Electrical
specications…………………………………………………………………………………………………… 23 Power
cord…………………………………………………………………………………………………………………..23 Plugging to AC
mains……………………………………………………………………………………………………. 23 Power
consumption…………………………………………………………………………………………………………24 Powering
on/off……………………………………………………………………………………………………………………. 24
3
Operation…………………………………………………………………………………………………………………………………….. 25 LS10 LED
colors……………………………………………………………………………………………………………………..25 Reset
button…………………………………………………………………………………………………………………………..25 LS10
Manager……………………………………………………………………………………………………………………… 26
Specications………………………………………………………………………………………………………………………………… 27
Appendix……………………………………………………………………………………………………………………………………… 30
Appendix A: Glossary……………………………………………………………………………………………………………..30 Appendix B:
Approvals…………………………………………………………………………………………………………… 31
4
Safety
Safety
Important safety instructions
Inspect the product before operation. If any sign of defect or damage is
detected, immediately withdraw the product from use for maintenance. Perform
preventive maintenance at least once a year. Refer to the preventive
maintenance section for a list of actions and their periodicity. Insufcient
upkeep of the product can void the warranty. Verify the electrical conformity
and compatibility of the mains supply. Only connect the product to an AC power
source rated 100-240 V, 50-60 Hz or to a DC power source with double
insulation or reinforced insulation rated 24 V and 10 W maximum. The product
draws 10 W (typical). The product draws 20 W (typical) when it powers another
LS10. WARNING: The product is of Class 1 construction and shall be connected
to a mains socket outlet with a protective connection to earth. When the
product is used in a three-phase circuit, verify the electrical conformity and
compatibility of the three-phase circuit. Verify that the three phases work,
and balance the loads between the three phases. Verify that the neutral and
earth work. Never try to emulate a 230 V circuit connecting an apparatus to
two live wires of a 120 V three-phase circuit. Never try to emulate a 200 V
circuit connecting an apparatus to two live wires of a 100 V three-phase
circuit. Electrical generator You must power on the generator before powering
on the product. Verify that the product is turned off before powering on the
generator. Never incorporate equipment or accessories not approved by
L-Acoustics. Read all the related PRODUCT INFORMATION documents shipped with
the products before exploiting the system. Intended use This system is
intended for use by trained personnel for professional applications. As part
of a continuous evolution of techniques and standards, L-Acoustics reserves
the right to change the specications of its products and the content of its
documents without prior notice. Check www.l-acoustics.com on a regular basis
to download the latest document and software updates. Do not expose the
product to extreme conditions. Do not expose the product to moisture (rain,
mist, sea spray, steam, humidity, condensation…) or excessive heat (direct
sun, radiator…) for a long period of time. For more information, refer to the
Products weather protection document, available on the website. Do not use the
product outside its operating temperature range. The product operates at a
room temperature between -5 °C / 23 °F and 50 °C / 122 °F. Do not expose the
product to direct sun.
Only use the product in a conformed electro-magnetic environment (EN55035
standard).
Product disconnection To completely disconnect this product from the mains,
disconnect the power supply cord plug from the mains socket outlet.
LS10 owner’s manual (EN) version 2.2
5
Safety
Power supply cord and socket accessibility The main plug of the power supply
cord shall remain easily accessible. The mains socket outlet shall be easily
accessible. Avoid radio interference. This product has been tested and
complies with the limits indicated in the EMC directive (Electro Magnetic
Compatibility). These limits are designed to provide reasonable protection
against harmful interference from electrical equipment, but it cannot be
guaranteed that interference will never occur.
Read the maintenance section of this document before servicing the product.
Contact L-Acoustics for advanced maintenance. Any unauthorized maintenance
operation will void the product warranty. Shipping Use the original packaging
for shipping the product. This marking indicates that this product should not
be disposed of with other household waste throughout the EU. To prevent
possible harm to the environment or human health from uncontrolled waste
disposal, recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and collection
systems or contact the retailer where the product was purchased. They can take
this product for environmentally safe recycling.
6
LS10 owner’s manual (EN) version 2.2
Introduction
LS10 AVB switch
Introduction
LS10 is an AvnuTM-certied AVB switch that integrates seamlessly within the
L-Acoustics ecosystem to further simplify connectivity, uniting audio and
control distribution. LS10 runs out-of-the-box AVB, providing a reliable
network solution that does not require IT expertise.
On its own or as an integral part of the LA-RAK II AVB, LS10 distributes audio
and control via front and rear etherCONTM connectors and SFP cages, enabling
long-distance optical links. Two units mounted side-by-side on the dedicated
1U rack shelf allow to create a seamless redundant network effortlessly.
Upgrading LA-RAK II to LA-RAK II AVB is possible.
The rugged LS10 incorporates features designed to overcome the challenges of
touring events but also installation applications. The quick, 5-second,
startup time allows for rapid recovery in case of power loss. A congurable GPO
port enables status monitoring and the auxiliary DC input offers ultimate
reliability.
With LS10, lightning-quick setup of a stable distribution of your AVB signal
is ensured without the need for extensive IT knowledge or experience.
How to use this manual
The LS10 owner’s manual is intended for all actors involved in the system
design, implementation, preventive and corrective maintenance of the LS10
product. It must be used as follows:
1. Read the technical description for an overview of all product elements,
their features, and their compatibilities. · Technical description (p.10)
2. Before installing the product, perform mandatory inspections and
functional checks. · Inspection and preventive maintenance (p.12)
3. To deploy the product, follow the step-by-step installation instructions
and refer to the cabling schemes. · Installation (p.14) · Network cabling
(p.19)
4. To congure the settings and parameters of the product, follow the step-by-
step operation instructions. · Operation (p.25)
As part of a continuous evolution of techniques and standards, L-Acoustics
reserves the right to change the specications of its products and the content
of its documents without prior notice.
Check www.l-acoustics.com on a regular basis to download the latest document
and software updates.
Contact information
For information on advanced corrective maintenance: · contact your Certied
Provider or your L-Acoustics representative · for Certied Providers, contact
the L-Acoustics customer service: customer.service@l-acoustics.com
LS10 owner’s manual (EN) version 2.2
7
Introduction
Symbols
The following symbols are used in this document: This symbol indicates a
potential risk of harm to an individual or damage to the product. It can also
notify the user about instructions that must be strictly followed to ensure
safe installation or operation of the product. This symbol indicates a
potential risk of electrical injury. It can also notify the user about
instructions that must be strictly followed to ensure safe installation or
operation of the product. This symbol noties the user about instructions that
must be strictly followed to ensure proper installation or operation of the
product.
This symbol noties the user about complementary information or optional
instructions.
Do not open unless authorized. This symbol indicates the presence of
electrical shock hazards. It also indicates that no maintenance performed by
the end user requires access to internal components.
Revision history
version number 1.0 2.0
2.1 2.2
publication date Jun. 2019 May 2020
Jul. 2020 Jul. 2021
modication
Initial version.
Updated protection ratings information, altitude specication, and EMC
standard.
Added Declaration of Conformity.
· Added information about using LS10 as a network switch for a local area
network.
· Moved information about LS10 Manager and USB Terminal (former Switch
Conguration Tool) to LA Network Manager Help.
8
LS10 owner’s manual (EN) version 2.2
System components
System components
This manual is about LS10 only.
Rigging accessory LS10-RAKSHELF Rack
1U Rack shelf for two LS10
LA-RAK II AVB
Software applications LS10 Manager
Touring rack containing three LA12X, LA-POWER II for power distribution,
LAPANEL II for audio and network distribution, and two LS10 for AVB
distribution
Application for remote monitoring of LS10
Cables
· 1 × 6-point terminal block connector (PhoenixTM MSTB 2,5/ 6-ST – 1754520)
Rigging elements
LS10-RAKSHELF
Illustrations
LA Network Manager (which includes LS10 Manager)
LS10 owner’s manual (EN) version 2.2
9
Technical description
Technical description
Main features
LS10 is a network switch as per IEEE 802.1Q standard, with ten IEEE 802.3
Ethernet ports. It can also operate as a hub. LS10 can be used in computer
rooms or facilities which are managed and maintained by non-communication
operators. To use LS10 as a hub, connect it to a computer using a RJ45 network
cable.
Components
LS10 has 10 Ethernet ports: · 5 Ethernet etherCON I/Os 1 Gb/s (front side) · 3
Ethernet etherCON I/Os 1 Gb/s (rear side) · 2 SFP cages supporting 1 Gb/s
interfaces
In addition, the switch features: · 1 Mains power input, IEC C13 V-Lock
compatible socket · 1 6-point terminal block that gathers: · 1 24 V DC IN / 1
24 V DC OUT pin for power supply backup · GPO for status control · 1 USB port
for maintenance and switch conguration
10
LS10 owner’s manual (EN) version 2.2
Front and rear panels
5
12 3
4
Technical description
6
7
8
9
1
1 power indicator
2
1 fault indicator
3
1 Reset button
4
10 link status/port indicators
5
5 Ethernet etherCON I/Os
10
6 7 8 9 10
2 SFP cages 1 female micro type USB port 3 Ethernet etherCON I/Os 1 × 6-point terminal block, step 5 mm 1 Mains power input, IEC C13 V-Lock compatible socket
Ethernet ports
LS10 features Ethernet ports that can operate at 10 Mbit/s, 100 Mbit/s or 1
Gb/s, in half-duplex or full duplex mode. The operating mode and speed are
automatically negotiated with the connected device. The 8 ports equipped with
RJ45 also feature auto MDI/MDIX detection to use straight or crossover cables.
LS10 supports the management of up to 150 AVB streams regardless of the number
of channels of these streams.
Power supply
LS10 relies on a universal Switched Mode Power Supply (SMPS) suitable for
mains from 100 V AC to 240 V AC (± 10%), 50 Hz to 60 Hz.
LS10 owner’s manual (EN) version 2.2
11
Inspection and preventive maintenance
Inspection and preventive maintenance
How to do preventive maintenance
Inspect the product periodically as indicated, and after any corrective
maintenance operation. Structure and cleanness Before and after each
deployment (touring applications), or at least once a month (xed
installations):
· CHK – External structure (p.12) · CHK – External cleanness (p.12)
Functionalities At least once a year: · CHK – Network functionalities and
rmware (p.13)
CHK – External structure
The
icon indicates a visual inspection.
chassis is not damaged
front and rear connectors are not damaged
CHK – External cleanness
Use a dry cloth to remove any dust from the side grills.
12
LS10 owner’s manual (EN) version 2.2
Inspection and preventive maintenance
CHK – Network functionalities and rmware
Equipment · computer with LA Network Manager version 3.1.0 minimum and CAT5e
cable
It is recommended to use the latest version of LA Network Manager and the
rmware.
Procedure 1. Connect LS10 to an Ethernet port of a computer running LA Network
Manager.
Use the CAT5e cable. 2. Open the LS10 Manager application.
a) Open LA Network Manager. b) Click > Utilities > LS10 Manager.
Refer to the LA Network Manager help for more information. c) Scan the
network. 3. Check that the switch is detected by the application. Refer to
LS10 Manager (p.26) for more information. 4. Check that all L-Acoustics
switches in the system run the same version of the rmware.
LS10 owner’s manual (EN) version 2.2
13
Installation
Installation
Mounting
LS10 is one rack unit high (1U) and a half rack unit wide. LS10-RAKSHELF is a
rigging accessory that can contain up to two LS10 side by side. LS10-RAKSHELF
is mounted to LA-RAK II AVB and can be mounted to LA-RAK II as well as other
19-inch racks.
Mounting two LS10 on LS10-RAKSHELF
Tools · torque screwdriver · T10 Torx bit
Material
6 × M3×6 Torx screws There are three different mounting congurations for LS10
on LS10-RAKSHELF:
· side by side in front position (default)
· side by side in rear position
· side by side with one in inverted position
Procedure 1. Turn upside down one or two LS10 and revert the LS10-RAKSHELF on
top.
14
LS10 owner’s manual (EN) version 2.2
2. Place the screws in the appropriate holes.
Installation
3. Tighten the screws.
1 N.m T10
4. Turn back the assembly to nominal position for cabling and mounting.
LS10 owner’s manual (EN) version 2.2
15
Installation
Ventilation
LS10 is equipped with one grill on each side to ventilate the system. Do not
block the side ventilation grills. Install the switch with the side panels at
a minimum distance of 5 cm (1.9 in)* from any external object or structure.
The same distance of 5 cm must be guaranteed on both sides of the rack. When
rack-mounted, make sure airow is not reduced.
General Purpose Output (GPO)
LS10 features a 6-point terminal block on the rear panel that includes a
congurable GPO to indicate the presence of a fault on the LS10. It can be
connected with a 6-point terminal block. The pitch of the connector is 5 mm.
GPO
6-point terminal block GPO is controlled by a Normally Open (NO) relay that
can operate in a circuit with up to 30 V DC, 1 A. Relay max rating
GPO PIN 3 PIN 4
30 V DC, 1 A
6-point terminal block
Relay is open when the unit is unpowered. GPO can be congured using the
L-Acoustics LS10 Manager.
For more information, refer to the LS10 Manager (p.26) section. * This
distance is respected when mounted in LA-RAK II AVB.
16
LS10 owner’s manual (EN) version 2.2
24 V DC Input and Output
24 V DC Input and Output pins allow to power another LS10 with a redundant
powering.
Installation
It is also possible to power LS10 with an external power supply. Backup power
cable In case of component fault inside one LS10, the other LS10 will
automatically provide backup power thanks to this cable. To do so, each LS10
must be connected to independent power sources. This cable can be made with
two PhoenixTM connectors (reference MSTB 2,5/ 6-ST – 1754520 for example) and
a cable with three conductors such as Alpha WireTM (reference 1896L SL005).
Connectors and cable conductors are connected as follows:
· cable conductor from PIN 1 to PIN 5 · cable conductor from PIN 2 to PIN 2 ·
cable conductor from PIN 5 to PIN 1
Backup powering
LS10 owner’s manual (EN) version 2.2
17
Installation
External 24 V DC powering
24 V DC ± 10% 10 W
External power supply
24 V DC IN = PIN 5 GND = PIN 2
18
LS10 owner’s manual (EN) version 2.2
Network cabling Connection panels
LS10 features connectors on its front and rear panels for network connection.
Installation
1
2
3
4
1
5 1 Gb/s Ethernet etherCON I/Os (front)
2
2 SFP cages
3
1 USB port
4
3 1 Gb/s Ethernet etherCON I/Os (rear)
SFP cages
The SFP cages are compatible with RJ45 or optical modules. They can operate at
up to 1 Gb/s. The SFP cages allow to extend the maximum link distance when
using optical modules.
LS10 can work with OM3 ber optic cables with 1000BASE-SX SFP modules (LC
connector, 850 nm). The maximum link length is 550 m. The ber bending radius
(maximum bending capacity) depends on the cable manufacturer recommendation.
In any case the ber bending radius must not be less than 15 times the cable’s
outside diameter.
L-Acoustics has tested the following SFP modules: · Avago AFBR-5710PZ · FS
SFP1G-SX-85 · Finisar FTLF8519P3BNL
USB
The female micro type USB port is used for maintenance operations and for
switch conguration. Refer to LS10 Manager (p.26) for more information.
Ethernet connectors
The Ethernet etherCON I/Os allow to create a local area network (LAN) using
Ethernet or Ethernet AVB devices such as P1, LA4X or LA12X.
A LAN network can be created by connecting the switch to a router, and
Ethernet devices to the switch, using industry standard cables tted with RJ45
connectors.
Multiple network topologies such as star and hybrid are congurable for L-NET
or AVB networks. The computer and the switches are connected to each other
using industry standard cables tted with optical modules or RJ45 connectors.
Refer to the LA Network Manager Help for more information on how to create an
L-NET or AVB network in star or hybrid topologies.
LS10 owner’s manual (EN) version 2.2
19
Installation
Cabling examples
Example of a local area network
Computer
Computer
Computer
LS10
front rear
Internet
Router
Ethernet
20
LS10 owner’s manual (EN) version 2.2
Example of non-redundant network with hybrid topology LA12X
LA4X
LA4X
Installation
Console
LS10
front rear
P1
Ethernet Ethernet AVB Computer
LS10 owner’s manual (EN) version 2.2
21
Installation
Example of redundancy topology
LS10 P1
front rear
LS10
front rear
rear front
Computer
primary network secondary network
22
LS10 owner’s manual (EN) version 2.2
Installation
Connecting to AC mains
Electrical specications
AC mains specications
Verify the electrical conformity and compatibility of the mains supply. Only
connect the product to an AC power source rated 100-240 V, 50-60 Hz or to a DC
power source with double insulation or reinforced insulation rated 24 V and 10
W maximum. The product draws 10 W (typical). The product draws 20 W (typical)
when it powers another LS10. WARNING: The product is of Class 1 construction
and shall be connected to a mains socket outlet with a protective connection
to earth.
Three-phase circuit
When the product is used in a three-phase circuit, verify the electrical
conformity and compatibility of the three-phase circuit. Verify that the three
phases work, and balance the loads between the three phases. Verify that the
neutral and earth work. Never try to emulate a 230 V circuit connecting an
apparatus to two live wires of a 120 V three-phase circuit. Never try to
emulate a 200 V circuit connecting an apparatus to two live wires of a 100 V
three-phase circuit.
Power cord
The removable IEC cord is tted with a female IEC C13 connector with V-Lock at one end and a country-specic plug at the other end.
type CE CN JP US
plug CEE 7/7, earthed GB 2099, earthed JIS C 8303, earthed NEMA 5-15, earthed
cable ratings 10 A / 250 V 10 A / 250 V 7 A / 125 V 10 A / 125 V
live brown black
neutral blue white
ground green/yellow
green
Strictly apply the specic safety regulations of the country of use. Do not defeat the ground connection of the supplied power cord using an adaptor or any other methods. A suitable plug must be wired to the INT power cord. If the power plug does not match the local power outlet, have a qualied electrician wire a suitable plug. Verify that the plug conforms to the specic voltage and current rating given in section Electrical specications (p.23).
Plugging to AC mains
Procedure 1. Connect the power cord female IEC C13 connector to the switch male IEC C14 socket.
Check that the cable is properly locked.
2. Connect the power cord country-specic plug to the mains socket.
LS10 owner’s manual (EN) version 2.2
23
Installation
Power consumption
LS10 power requirement is 10 W. For an LS10 that powers another LS10 via 24 V
DC, it is 20 W.
Powering on/off
LS10 features one power LED indicator. To power LS10 on, connect the IEC
cable. LS10 is detected and operational in less than 5 seconds. To power the
switch off, unplug the power cord from the mains socket.
24
LS10 owner’s manual (EN) version 2.2
Operation
LS10 LED colors
LS10 is equipped with 12 LED indicators:
Operation
· 10 Link/Act indicators · 1 Fault indicator · 1 Power indicator Colors and
meaning Power
Fault
Link/act indicators
green off red off green blink off
powered unpowered fault detected nothing to report link established link active link not established
Reset button
It is possible to reset LS10 to factory default settings using the Reset
button. Press the RST button and hold it for seven seconds to set back the
switch to factory default settings. It sets back:
· the default IP address to 192.168.1.200 · the default subnet mask to
255.255.255.0 · the default options of the switch It is also possible to reset
LS10 with the LS10 Manager. Refer to LS10 Manager (p.26).
LS10 owner’s manual (EN) version 2.2
25
Operation
LS10 Manager
LS10 can be remotely congured using the LS10 Manager application. The
application is available from the main menu of LA Network Manager, Utilities
section, version 3.2.1 minimum.
LS10 Manager allows to congure the connected LS10 with the following
parameters: · display and change the IP address · update the rmware to the
latest version · check the status of the switch and the ports · customize the
switch options (RSTP, gPTP, Error Auto Recovery) · dene the fault conditions
to include in the GPO (General Purpose Output Logic) · retrieve the embedded
log les when required · reset to factory default settings if necessary
To be detected by LS10 Manager, LS10 must be connected to the computer with an
Ethernet cable and its IP must be on the same subnet as the computer. If LS10
must be used on a different subnet, connect it with a USB cable and use the
USB Terminal application for basic IP settings. Refer to the LA Network
Manager Help for more information on LS10 Manager and USB terminal.
26
LS10 owner’s manual (EN) version 2.2
Specications
Specications
LS10 specications
All values given in this section are typical values. General
Mains rating Power consumption Backup power circuit
Startup time Plug-and-play
100 V AC – 240 V AC (± 10%), 50 Hz – 60 Hz 10 W – 20 W max when powering another LS10 24 V DC back-up input 24 V DC output for powering another LS10 Ready to forward AVB streams in 5 seconds open standard (no license required), AVB-enabled without conguration, no manual conguration required
Storage and operating conditions
Storage temperature Operating temperature Maximum altitude Climate
-5 °C / 23 °F to 70 °C / 158 °F -5 °C / 23 °F to 50 °C / 122 °F 2000 m moderate, tropical
Interface
Indicators Button
1 LED for power status, 1 LED for fault status 10 LEDs for link/act status reset to factory settings
Ethernet port features
Management
Port sensing Auto crossover Auto sensing AVB ports
gPTP grandmaster capable, priority selection RSTP: enable/disable Auto negotiation MDI / MDIX (allows to use straight or cross cables) Full or Half Duplex (Gigabit is always Full Duplex Mode) 10 ports at 10/100/1000 Mb/s
Connectors
Network Mains input Terminal block connector
USB
8 × Ethernet etherCON I/O (5 on front, 3 on rear)
2 × SFP cages
IEC C13 V-Lock compatible socket
5 mm 6-point terminal block connector for GPO and DC powering with: · 1 × 24 V
DC power output (max 10 W) to power another LS10 · 1 × 24 V DC backup power
input (max 10 W) · 1 × GPO for fault indication (Relay, max 30 V DC / 1 A)
female micro USB type
LS10 owner’s manual (EN) version 2.2
27
Specications
AVB Featured AVB entities Standards
Supported streams
Management IP Firmware update Physical data Height × Width Weight Finish
Protection rating
LS10 dimensions
216 mm / 8.5 in
AvnuTM-certied AVBBridge Ethernet AVB:
IEEE 802.1BA-2011 standard augmented by Avnu ProAV 1.1 requirements Number:
150 Class: A and B
static through Ethernet
1.7 in × 8.5 in (1U × 1/2U) 1 kg / 2.2 lb black IP2x
42 mm / 1.7 in
133 mm / 5.2 in
149 mm / 5.8 in
28
LS10 owner’s manual (EN) version 2.2
LS10-RAKSHELF specications
Description
Weight (net) Material
1U Rack shelf for two LS10 6 × M3×6 Torx screws 1.1 kg / 2.4 lb electrogalvanized steel
LS10-RAKSHELF dimensions
483 mm / 19 in
465 mm / 18.3 in 437 mm / 17.2 in
31.8 mm / 1.2 in
Specications
44 mm / 1.7 in
193 mm / 7.5 in
LS10 owner’s manual (EN) version 2.2
29
Appendix
Appendix
Glossary
CE CHK CN D/R JP KR SMPS US
Europe check procedure China disassembly/reassembly procedure Japan repair kit Switched Mode Power Supply (power supply inside of the amplied controller) United States
30
LS10 owner’s manual (EN) version 2.2
Approvals
Appendix
LS10 owner’s manual (EN) version 2.2
31
Appendix
LS10 is compliant with the following:
Avnu Alliance and the Avnu design mark are registered trademarks and/or
service marks of Avnu Alliance.
32
LS10 owner’s manual (EN) version 2.2
L-Acoustics
13 rue Levacher Cintrat – 91460 Marcoussis – France +33 1 69 63 69 63 –
info@l-acoustics.com www.l-acoustics.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>