Expert Grill GBC1846WS Outdoor LP Gas Barbecue Grill Owner’s Manual
- June 9, 2024
- Expert Grill
Table of Contents
- INTRODUCTION
- Important Safeguards Warning
- Limited Warranty
- Expanded View
- Tools Required for Assembly (Included)
- Assembly Instructions
- DO NOT RETURN TO PLACE OF PURCHASE.
- Assemble Cart Frames and Shelves
- Assemble Legs
- Attach Leg Connectors
- Attach Front Panel and Cart Frame Support A&B
- Attach Cart Frame Support B&C
- Attach LP Gas Tank Retainer Wire, Axle and Wheels
- Attach Grill Body Assembly
- Attach Hanlde, Heat Shield and Side Valve
- Attach Control Knobs, Side Burner and Side Burner Grid
- Insert Warming Rack
- Insert Heat Plates and Cooking Grid
- Insert Grease Cup
- Installing LP Gas Tank
- Operating Instructions
- Cleaning and Care
- Troubleshooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 2 Phillips Head Screwdriver 1 pc
Expert Grill GBC1846WS Outdoor LP Gas Barbecue Grill
INTRODUCTION
The use and installation must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, or the Standard for Recreational Vehicles, ANSI A 119.2/NFPA 1192, and CSA Z240 RV Series, Recreational Vehicle Code, as applicable .
THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION . PLEASE READ
AND KEEP FOR FUTURE REFERENCE .
If you are assembling this unit for someone else, give this manual to them to
read and save for future reference .
California Proposition 65: Combustion by-products produced when using this
product contain chemicals known to the State of California to cause cancer,
birth defects, and other reproductive harm .
California Proposition 65: Wash your hands after handling this product .
California Proposition 65: Handling the brass material on this product exposes
you to lead, a chemical known to the State of California to cause cancer,
birth defects, or other reproductive harm
WARNING
FOR YOUR SAFETY:
- Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
- Read the installation, operation, and maintenance instructions thoroughly before installing or servicing this equipment.
- Failure to follow these instructions could result in fire or explosion, which could cause property damage, personal injury, or death.
- This instruction manual contains Important information necessary for the proper assembly and safe use of the appliance.
- Read and follow all warnings and instructions before assembling and using the appliance.
- Follow all warnings and instructions when using the appliance.
- Keep this manual for future reference.
WARNING
FOR YOUR SAFETY:
- Do NOT store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance.
- An LP cylinder not connected for use shall NOT be stored in the vicinity of this or any other appliance.
DANGER
Never operate this appliance unattended.
DANGER
If you smell gas –
- Shut off gas to appliance.
- Extinguish any open flame.
- Open lid.
- If odor continues, keep away from the appliance and immediately call your gas supplier or your fire department.
WARNING
FOR YOUR SAFETY:
For Outdoor Use Only
(outside any enclosure)
Important Safeguards Warning
-
This grill is for outdoor use only, and should not be used in a building, garage or any other enclosed area.
-
Do NOT operate, light or use this appliance within ten feet (3.05 m) of walls, structures or buildings.
-
For residential use only. This grill is NOT for commercial use.
-
This grill is not intended for and should never be used as a heater. TOXIC fumes can accumulate and cause asphyxiation.
-
This grill is safety certified for use in the United States and/or Canada only. Do NOT modify for use in any other location. Modification will result in a safety hazard and will void your warranty.
-
This grill is for use with liquid propane (LP) gas only. The conversion to or attempted use of natural gas in this LP gas grill is dangerous, may cause
bodily harm and will void your warranty. -
LP gas characteristics:
- a. LP gas is flammable and hazardous if handled improperly. Become aware of the characteristics before using any LP gas product.
- b. LP gas is explosive under pressure, heavier than air, and settles/pools in low areas.
- c. LP gas in its natural state has no odor. For your safety, an odorant is added that smells like rotten cabbage.
- d. Contact with LP gas can cause freeze burns to skin.
-
Apartment dwellers: Check with management to learn the requirements and fire codes for using a LP gas grill in your apartment complex. If allowed, use outside on the ground floor with a ten foot (3.05 m) clearance from any structure. Do NOT use on or under balconies.
-
LP gas cylinder needed to operate. Only cylinders marked “propane” may be used.
-
The LP gas cylinder must be constructed and marked in accordance with the Specifications for LP-gas Cylinders of the U.S. Department of
Transportation (D.O.T.) or the National Standard of Canada, CAN/CSA B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods; and Commission. -
LP gas cylinder must be arranged for vapor withdrawal.
-
The LP gas cylinder must have a listed overfilling prevention device (OPD).
-
Only use LP gas cylinders equipped with a cylinder connection device compatible with the connection for outdoor cooking appliances.
-
The LP gas cylinder must have a cylinder collar to protect the cylinder valve.
-
Never use an LP gas cylinder with a damaged body, valve, collar or footing.
-
Dented or rusted LP gas cylinders may be hazardous and should be checked by your LP gas supplier prior to use.
-
The LP gas cylinder should not be dropped or handled roughly.
-
LP gas cylinders must be stored outdoors out of the reach of children and must not be stored in a building, garage or any other enclosed area. Your cylinder must never be stored where temperatures can reach over 125°F.
-
Do NOT insert any tool or foreign object into the valve outlet or safety relief valve. You may damage the valve and cause a leak. Leaking propane may result in an explosion, fire, severe personal injury or death.
-
Do NOT block holes in sides or back of grill.
-
Never keep an LP gas cylinder in a hot car or trunk. Heat will cause the gas pressure to increase, which may open the relief valve and allow gas to escape.
-
Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.
-
If grill is not in use, the gas must be turned off at the supply cylinder and disconnected.
-
Do NOT store a spare LP gas cylinder under or near this appliance.
-
Never fill the cylinder beyond 80 percent full.A fire causing serious injury or damage to property may occur if the above is not followed exactly.
-
Never attempt to attach this grill to the self-contained LP gas system of a camper trailer, motor home or house.
-
Never use charcoal, lighter fluid, lava rocks, gasoline, kerosene or alcohol with this product.
-
Your grill has been checked at all factory connections for leaks. Re-check all connections as described in the “Operating Instructions” section, as shipping can loosen connections.
-
Check for leaks even if your unit was assembled for you by someone else.
-
Do NOT operate if a gas leak is present. Gas leaks may cause a fire or explosion.
-
You must follow all instructions in the “Checking for Leaks” section before operating. To prevent fire or explosion hazard when testing for a leak:
- a. Always perform a leak test before lighting the grill and each time the cylinder is connected for use.
- b. No smoking. Do NOT use or permit sources of ignition in the area while conducting a leak test.
- c. Conduct the leak test outdoors in a well-ventilated area.
- d. Do NOT use matches, lighters, or a flame to check for leaks.
- e. The use of alcohol, prescription or non-prescription drugs may impair the consumer’s ability to properly assemble or safely operate the appliance.
- f. Strong odors, colds, sinus congestion, etc. may prevent the detection of propane. Use caution and common sense when testing for leaks.
- g. Do NOT use grill until any and all leaks are corrected.
If you are unable to stop a leak, disconnect the LP gas supply. Call a gas appliance serviceman or your local LP gas supplier.
-
This grill is designed to operate at an inlet pressure of: 11 inches water column.
-
Do NOT store or use gasoline or other flammable liquids or vapors within 25 feet (7.62 m) of this appliance.
-
Do NOT use in an explosive atmosphere. Keep grill area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
-
Minimum clearance from sides and back of unit to combustible construction is 36 inches (91.4 cm). Do NOT use this appliance under any type of overhang or roof.
-
It is essential to keep the grill’s valve compartment, burners and circulating air passages clean.
-
Inspect grill before each use.
-
Do NOT alter grill in any manner. Any alteration will void your warranty.
-
Do NOT use the grill unless it is COMPLETELY assembled and all parts are securely fastened and tightened.
-
Do NOT build this model of grill in any built-in or slide-in construction. Ignoring this warning could cause a fire or an explosion that can damage property and cause serious bodily injury or death.
-
This grill should be thoroughly cleaned and inspected on a regular basis.
-
Clean and inspect the hose before each use of the appliance. If there is evidence of abrasion, wear, cuts or leaks, the hose must be replaced prior to operation.
-
Use only the regulator and hose assembly provided. Use only the replacement regulator and hose assembly specified by RevoAce Inc. Limited
-
Use only RevoAce Inc. Limited factory-authorized parts. The use of any part that is not factory-authorized can be dangerous and will void your warranty.
-
Do NOT operate this appliance without reading “Operating Instructions” in this manual.
-
Do NOT touch metal parts of grill until they have completely cooled to avoid burns, unless you are wearing protective gear (pot holders, gloves, BBQ mittens, etc.).
-
Do NOT install or use in or on boats or recreational vehicles.
-
When cooking, fire extinguishing materials should be readily accessible. In the event of an oil/grease fire, do NOT attempt to extinguish with water.
Use type BC dry chemical fire extinguisher or smother with dirt, sand or baking soda. -
Do NOT use grill in high winds.
-
Never lean over the grill when lighting.
-
Do NOT leave a lit grill unattended. Keep children and pets away from grill at all times.
-
Do NOT leave grill unattended while preheating or burning off food residue on high. If grill has not been cleaned, a grease fire can occur that may damage the product.
-
Do NOT place empty cooking vessels on the appliance while in operation.
-
Use caution when placing anything on the grill while the appliance is in operation.
-
Do NOT attempt to move grill when in use. Allow the grill to cool before moving or storing.
-
LP gas cylinder must be properly disconnected and removed prior to moving this grill.
-
Storage of grill indoors is permissible only if the cylinder is disconnected, removed from the grill and properly stored outdoors.
-
Always open grill lid carefully and slowly as heat and steam trapped within grill can cause severe burns.
-
Do NOT attempt to disconnect the gas regulator from the cylinder or any gas fitting while the grill is in use.
-
Always place your grill on a hard, non-combustible, level surface. An asphalt or blacktop surface may not be acceptable for this purpose.
-
Move gas hoses as far away as possible from hot surfaces and dripping hot grease.
-
Keep all electrical cords away from a hot grill.
-
After a period of storage and/or nonuse, check for leaks, burner obstructions and inspect for any abrasion, wear or cuts to the hose.
-
Failure to open lid while igniting the grill’s burners, or not waiting 5 minutes to allow the gas to clear if the grill does not light, may result in an explosive flame-up.
-
Never operate grill without its heat plates installed.
-
Always use a meat thermometer to ensure food is cooked to a safe temperature.
-
Use protective gloves when assembling this product.
-
Do NOT force parts together as this can result in personal injury or damage to the product.
-
Never cover entire cooking area with aluminum foil.
-
Deaths, serious injury or damage to property may occur if the above is not followed exactly.
Limited Warranty
RevoAce Inc. Limited (“RA”) warrants to the original retail purchaser of this product, and to no other person, that if this product is assembled, maintained, and operated in accordance with the printed instructions accompanying it, then for a period of five (5) years for the burners and one (1) year for all remaining parts from the date of purchase, all parts in such product shall be free from defects in material and workmanship. RA may require reasonable proof of your date of purchase. Therefore, you should retain your sales slip or invoice. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service and which RA shall determine in its reasonable discretion upon examination to be defective. Before returning any parts, you should contact RA’s Customer Care Department using the contact information listed below. If RA conforms, after examination, a defect covered by this Limited Warranty in any returned part, and if RA approves the claim, RA will replace such defective part without charge. If you return defective parts, transportation charges must be prepaid by you. RA will return replacement parts to the original retail purchaser, freight or postage prepaid. This Limited Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration, misapplication, improper installation or improper maintenance or service by you or any third party, or failure to perform normal and routine maintenance on the product as set out in this owner’s manual. In addition, the Limited Warranty does not cover damage to the finish, such as scratches, dents, discoloration, rust or other weather damage, after purchase.
This Limited Warranty is in lieu of all other express warranties. RA disclaims all warranties for products that are purchased from sellers other than authorized retailers or distributors, including the warranty of merchanta ility or the warranty of fitness for a particular purpose. RA ALSO DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. RA SHALL HAVE NO LIABILITY TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. RA further disclaims any implied or express warranty of, and assumes no responsibility for, defects in workmanship caused by third parties. This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some jurisdictions do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to everyone.
RA does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment, and no such representations are binding on RA.
RevoAce Inc. Limited
Hong Kong, China
1.800.694.0013
Expanded View
Parts List
1 | Handle | G1846-010 |
---|---|---|
2 | Warming Rack | G1846-060 |
3 | Brand Plate* | B0109-LBA |
4 | Heat Shield | G1846-020 |
5 | Lid | G1846-030 |
6 | Top Hinge (2)* | G1716-020 |
7 | Bottom Hinge (2)* | G1716-030 |
8 | Cooking Grid | G1846-070 |
9 | Grill Body Assembly* | G1846-050 |
10 | Burner (4)* | G1846-040 |
11 | Heat Plate (4) | G1716-080 |
12 | Left Side Shelf | G1716-090 |
--- | --- | --- |
13 | Control Knob (5) | G1025-255 |
14 | Regulator/Hose Assembly* | B0308-B18 |
15 | Grease Cup | B0219-H00 |
16 | Right Side Shelf | G1846-080 |
17 | Side Burner | G1846-090 |
18 | Side Burner Grid | B0404-C00 |
19 | Upper Cart Frame (2) | G1716-130 |
20 | Cart Frame Support A | G1846-100 |
21 | Lighting Hook* | B0223-D00 |
22 | LP Gas Tank Retainer Wire | G1716-100 |
23 | Front Panel | G1846-110 |
--- | --- | --- |
24 | Left Leg (2) | G1716-140 |
25 | Foot (2)* | B0305-C00 |
26 | Left Leg Connector | G1716-160 |
27 | Cart Frame Support B (2) | G1846-120 |
28 | Cart Frame Support C (2) | G1716-180 |
29 | Right Leg Connector | G1716-190 |
30 | Right Leg (2) | G1716-150 |
31 | Axle | G1716-312 |
32 | Wheel (2) | B0302-E11 |
Hardware
A Screw | M4x10 Nickel Plated Phillips Truss Head | 4 pcs |
---|---|---|
B Screw | M6x15 Nickel Plated Phillips Truss Head | 12 pcs |
C Screw | M6x45 Nickel Plated Phillips Truss Head | 12 pcs |
D Wing Screw | M6x16 Nickel Plated | 4 pcs |
E Nut | M10 Nickel Plated | 2 pcs |
F Wing Nut | M6 Nickel Plated | 4 pcs |
G Wing Nut | M6 Solid Nickel Plated | 2 pcs |
H Washer | ø18 Nickel Plated | 4 pcs |
I Washer | ø22 Nickel Plated | 2 pcs |
J Lock Washer | ø6 Nickel Plated | 2 pcs |
Tools Required for Assembly (Included)
-
2 Phillips Head Screwdriver 1 pc
-
M10 Wrench 2 pcs
Assembly Instructions
DO NOT RETURN TO PLACE OF PURCHASE.
For assistance, call 1-800-694-0013
toll-free . Please have your owner’s manual and model number available for
reference .
Note: The model number is printed on a label which can be found on the
inside door, back or side of the cart assembly .
Assembly Tips:
-
Select an area where you will assemble this product . To protect components, choose a smooth surface that’s free of cracks or openings .
-
Spread out all parts .
-
Tighten all hardware connections by hand first . Then, before completing each step, go back and fully tighten all hardware .
Be careful not to over-tighten . That could damage surfaces or strip threads . -
For best results, complete each step in the order presented
To complete assembly you will need:
- (1) Leak detection solution (instructions on how to make the solution are included in the “Operating Instructions” section of this manual) .
- (1) Precision-filled LP gas grill tank with Acme Type 1 external threaded valve connection (standard grill size) (not included)
Typical assembly is approximately one hour .
Assemble Cart Frames and Shelves
Assemble Legs
Attach Leg Connectors
Attach Front Panel and Cart Frame Support A&B
Attach Cart Frame Support B&C
Attach LP Gas Tank Retainer Wire, Axle and Wheels
Attach Grill Body Assembly
Attach Hanlde, Heat Shield and Side Valve
Attach Control Knobs, Side Burner and Side Burner Grid
Insert Warming Rack
Insert Heat Plates and Cooking Grid
Insert Grease Cup
Installing LP Gas Tank
To operate, you will need one precision-filled standard grill LP gas tank with external valve threads .
CAUTION LP gas tank must be properly disconnected and removed prior to moving this grill.
Inserting LP Gas Tank
Place precision-filled LP gas tank upright into the notches in the right cart
frame so the tank valve is facing the gas line connection
Securing LP Gas Tank
Secure tank by sliding the tank retainer wire over shoulder of LP gas tank
Connecting LP Gas Tank
- Before connecting, be sure there is no debris caught in the head of the LP gas tank, head of the regulator valve or in the head of the burner or burner ports.
- Connect regulator/hose assembly to tank by turning knob clockwise until it stops .
Disconnecting LP Gas Tank
-
Before disconnecting, make sure the LP gas tank valve is “CLOSED .”
-
Disconnect regulator/hose assembly from LP gas tank by turning knob counterclockwise until it is loose .
CAUTION: LP gas tank must be properly disconnected and removed prior to moving this grill. -
Place the protective cap cover on the LP tank and store the tank outdoors in a well ventilated area out of direct sunlight .
Operating Instructions
Checking for Leaks
Burner Connections
-
Make sure the regulator hose and valve connections are securely fastened to the burner and the tank .
-
Visually check the connection between the burner/venturi tube and orifice.
-
Make sure the burner/venturi tube fits over the orifice .
WARNING: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury or damage to property. -
Please refer to diagram for proper installation (Figure 1 and 2) .
-
If the burner/venturi tube does not rest flush to the orifice, as shown, please contact 1 .800 .694 .0013 for assistance
Tank/Gas Line Connection
- Make 2-3 oz . of leak detection solution by mixing one part liquid dishwashing soap with three parts water .
- Make sure control knobs are in the “ OFF” position (Figure 3) .
- Connect LP gas tank per “Installing LP Gas Tank” section .
- Turn LP gas tank valve to “OPEN .”
- Spoon several drops of solution, or use a squirt bottle, at all “X” locations (Figures 1, 2 and 4) .
- a . If any bubbles appear, turn LP gas tank valve to “CLOSED,” reconnect and re-test .
- b . If you continue to see bubbles after several attempts, turn LP gas tank valve to “CLOSED” and disconnect LP gas tank, per “Disconnecting LP Gas Tank” section .
- c . If no bubbles appear after one minute, turn LP gas tank valve to “CLOSED,” wipe away solution and proceed
Operating Main Burners
First Use
- Make sure all labels, packaging and protective films have been removed from the grill .
- Remove manufacturing oils before cooking on this grill for the first time by operating the grill for at least 15 minutes on ****(HIGH) with the lid closed . This will “heat clean” the internal parts and dissipate odors .
Lighting
CAUTION: Keep outdoor gas cooking appliance area clear and free from
combustible materials, gasoline and other flammable vapors and liquids.
CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
CAUTION: Attempting to light the burner with the lid closed may cause an
explosion.
-
Open lid .
-
Check for obstructions of airflow to the burners . Spiders, insects and webs can clog the burner/venturi tube . A clogged burner tube can lead to a fire .
-
All control knobs must be in the “ OFF” position (Figure 3) .
-
Connect LP gas tank per “Installing LP Gas Tank” section .
-
Turn LP gas tank valve to “OPEN .”
-
Push and turn control knob to ****(HIGH) . the burner should light . Repeat up to three times .
-
If ignition does not occur in 5 seconds, turn burner control knob “ OFF,” wait 5 minutes, and repeat lighting procedure .
-
If igniter does not light burner, use a lit match secured with the lighting rod (included with grill) to light burners . Access the burners through the cooking grid and heat plates . Position lit match near side of burner (Figure 5) .
Important: Always use the lighting rod (included) when lighting burners with a match . -
After lighting, observe the burner flame . Make sure all burner ports are lit and flame height matches illustration (Figure 6) .
Note: Each burner lights independently – repeat steps 5-9 for the other burners .
Turning Off
-
Turn LP gas tank valve to “CLOSED .”
-
Turn all control knobs clockwise to the “ OFF” position .
Note: A “poof” sound is normal as the last of the LP gas is burned . -
Disconnect LP gas tank per “Disconnecting LP Gas Tank” section .
Controlling Flare-ups
- If a grease fire develops, turn control knobs to the “ OFF” position and LP gas tank valve “CLOSED.” Do NOT use water on a grease fire. This can cause the grease to splatter and could result in serious burns, bodily harm or other damage.
- Do NOT leave grill unattended while preheating or burning off food residue on (HIGH). If grill has not been cleaned, a grease fire can occur.
Flare-ups are a part of cooking meats on a grill and add to the unique flavor
of grilling .
Excessive flare-ups can over-cook your food and be dangerous.
Important: Excessive flare-ups result from the build-up of grease in the
bottom of your grill .
If a grease fire occurs, close the lid AND turn the control knob(s) to “ OFF”
until the grease burns out . Be careful when opening the lid as sudden flare-
ups may occur .
If excessive flare-ups occur, do NOT pour water onto the flames
Minimize Flare-ups:
- Trim excess fat from meats prior to cooking .
- Cook high fat content meats on ****(LOW) setting or indirectly .
- Ensure that your grill is on a hard, level, non-combustible surface and the grease is allowed to drain into grease receptacle
CAUTION
If burner flame goes out during operation, immediately turn the control knobs
to the “ ****OFF” position,
LP gas tank valve “CLOSED” and open lid to let the gas clear for 5 minutes
before re-lighting.
CAUTION
Putting out grease fires by only closing the lid is not possible.
WARNING
When cooking, fire extinguishing materials should be readily accessible. In the event of an oil/grease fire, use type BC dry chemical fire extinguisher or smother with dirt, sand or baking soda. Do NOT attempt to extinguish with water.
Operating Side Burner
NOTE: Side burner can be used while main burners are operating .
Never use side burner as a grill.
CAUTION: Maximum weight for side burner and side shelf is 22 lbs.
CAUTION: Using pots larger than 6 quarts in capacity could exceed weight limit of the side burner shelf, resulting in failure of grill cart components.
CAUTION: Do NOT lean on the side burner shelf.
CAUTION: Attempting to light the burner with the lid closed may cause an explosion.
Lighting
-
Open lid .
-
Check for obstructions of airflow to the burners . Spiders, insects and webs can clog the burner/venturi tube A clogged burner tube can lead to a fire .
-
Control knob must be in the “ OFF” position (Figure 3) .
-
Connect LP gas tank per “Installing LP Gas Tank” section .
-
Turn LP gas tank valve to “OPEN .”
-
Push and turn control knob to (HIGH) . The burner should light . If not, repeat up to three times .
-
If ignition does not occur in 5 seconds, turn burner control knob “ OFF,” wait 5 minutes and repeat lighting procedure .
-
If igniter does not light burner, use a lit match secured with the lighting rod (included with grill) to light burners . Position the lit match near side of the burner (Figure 7) .
Important: Always use the lighting rod (included) when lighting burner with a match . -
After lighting, observe the burner flame . Make sure all burner ports are lit and flame height matches illustration (Figure 6) .
CAUTION: If burner flame goes out during operation, immediately turn the control knob to the “ OFF” position and LP gas tank valve “CLOSED” and open lid to let the gas clear for 5 minutes before re-lighting.
Turning Off
-
Turn LP gas tank valve to “CLOSED .”
-
Turn control knob clockwise to the “ OFF” position .
Note: A “poof” sound is normal as the last of the LP gas is burned . -
Disconnect LP gas tank per “Disconnecting LP Gas Tank” section .
Cooking
- Open lid and ignite the side burner per “Lighting” instructions .
- Adjust control knob to desired flame height .
- Place pan on center of grid .
- Cook and adjust temperature as needed .
- Turn grill off per “Turning Off” instructions .
Cleaning and Care
CAUTION
- All cleaning and maintenance should be done when grill is cool and with the fuel supply disconnected.
- Do NOT clean any grill part in a selfcleaning oven. The extreme heat will damage the finish.
- Do NOT enlarge valve orifices or burner ports when cleaning the valves or burners.
NOTICE
- This grill should be thoroughly cleaned and inspected on a regular basis.
- Abrasive cleaners will damage this product.
- Never use oven cleaner to clean any part of grill.
Before Each Use:
-
Keep the grill area clean and free from any combustible materials, gasoline, and other flammable vapors and liquids .
-
Do NOT obstruct the flow of the combustion of LP gas and the ventilation of air .
-
Keep the ventilation opening(s) of the LP gas tank area free and clear from debris .
-
Visually check the burner flames to make sure your grill is working properly (Figure 8) .
Figure 8
Burner Flame Conditions
Use this chart to see if your burners need to be cleaned.
Normal: Soft blue flames with yellow tips between 1 in . – 2 in . height
Needs cleaning: Noisy with hard blue flames .
Has to be replaced: Wavy with yellow flames
-
See sections below for proper cleaning instructions .
-
Check for obstructions of airflow to the burners . Spiders, insects and webs can clog the burner/venturi tube . A clogged burner tube can lead to a fire .
Cleaning Surfaces
- Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water .
- For stubborn surfaces, use a citrus-based degreaser and a nylon scrubbing brush .
- Rinse clean with water .
- Allow to air dry
Cleaning Main Burners
-
Turn LP gas tank valve to “CLOSED .”
-
Turn all control knobs clockwise to the “ OFF” position .
Note: A “poof” sound is normal as the last of the gas is burned . -
Disconnect LP gas tank per “Disconnecting LP Gas Tank” section .
-
Remove cooking grids and heat plates .
-
Remove burners by removing the fasteners, which secure the burners to the grill bottom .
-
Lift burners up and away from gas valve orifice .
-
Disconnect wire from spark electrode .
-
Clean venturi of each burner with small bottle brush or compressed air .
-
Remove all food residue and dirt from burner surface .
-
Clean any clogged ports with a stiff wire (such as an opened paper clip) .
-
Inspect burners for any damage (cracks or holes) . If damage is found, replace with new burner(s) from manufacturer .
-
Re-install burner(s) . Checking to insure that gas valve orifice is correctly positioned inside each burner/venturi tube . Also, check position of spark electrode .
-
Replace heat plate(s) and cooking grid(s) .
-
Connect LP gas tank per “Installing LP Gas Tank” section .
-
Perform leak test per “Checking for Leaks” section
Cleaning Side Burner
-
Turn LP gas tank valve to “CLOSED .”
-
Turn all control knobs clockwise to the “ OFF” position .
Note: A “poof” sound is normal as the last of the gas is burned . -
Disconnect LP gas tank per “Disconnecting LP Gas Tank” section .
-
Remove side burner grid .
-
Remove burner by removing the screws that secure the burner to the side shelf .
-
Lift burner up and away from gas valve orifice .
-
Clean venturi of burner with small bottle brush or compressed air .
-
Remove all food residue and dirt from burner surface .
-
Clean any clogged ports with a stiff wire (such as an opened paper clip) .
-
Inspect burner for any damage (cracks or holes) . If damage is found, replace with new burner from manufacturer .
-
Re-install burner(s) . Checking to insure that gas valve orifice is correctly positioned inside each burner/venturi tube . Also, check position of spark electrode .
-
Replace cooking grid(s) .
-
Connect LP gas tank per “Installing LP Gas Tank” section .
-
Perform leak test per “Checking for Leaks” section
Before Storing
-
Turn LP gas tank valve to “CLOSED .”
-
Turn all control knobs clockwise to the “ OFF” position .
Note: A “poof” sound is normal as the last of the gas is burned . -
Disconnect LP gas tank per “Disconnecting LP Gas Tank” section .
-
Clean all surfaces .
-
Lightly coat the burner(s) and cooking grid(s) with cooking oil to prevent excess rusting .
-
If storing the grill indoors, disconnect the LP tank per “Disconnecting LP Gas Tank” section .
-
Place the protective cap cover on the LP tank and store the tank outdoors in a well-ventilated area out of direct sunlight .
-
If storing the grill indoors, cover the grill and store in a cool dry place .
-
If storing the grill outdoors, cover the grill with a grill cover for protection from the weather
Troubleshooting
Problem | Possible Cause | Prevention/Cure |
---|---|---|
LP gas tank valve is closed | Make sure regulator is securely attached to |
the LP gas tank per “Installing LP Gas Tank,” then turn LP gas tank valve to
“OPEN”
LP gas tank is low or empty| Exchange, refill or replace LP gas tank
LP gas Leak| Turn LP gas tank valve to “CLOSED” • Wait 5 minutes for gas to
clear • Follow “Checking for Leaks” section
Wires or electrode covered with cooking residue| Clean wire and/or electrode
with rubbing alcohol
Electrode and burners are wet| Wipe dry with cloth
Electrode cracked/broken – sparks at crack| Replacement part(s) may be needed
– contact Customer Care at 1 .800 .694 .0013
Wire loose or disconnected| Reconnect wire or replacement part(s) may be
needed – contact Customer Care at 1 .800 .694 .0013
Wire is shorting (sparking) between ignitor and electrode| Replacement part(s)
may be needed – contact Customer Care at 1 .800 .694 .0013
Bad igniter| Replacement part(s) may be needed – contact Customer Care at 1
.800 .694 .0013
| No gas flow| Check if LP gas tank is empty A . If empty, exchange, refill
or replace LP gas tank B . If LP gas tank is not empty, refer to “Sudden drop
in gas flow or reduced flame height” (see below)
LP gas tank is low or empty| Exchange, refill or replace LP gas tank
LP gas|
- Turn LP gas tank valve to “CLOSED”
- Wait 5 minutes for gas to clear
- Follow “Checking for Leaks” section
Coupling nut and regulator not fully connected| Turn the coupling nut about
one-half to three-quarters additional turn until solid stop . Tighten by hand
only – do NOT use tools
Obstruction of gas flow|
- Clear burner/venturi tube
- Check for bent or kinked hose
Disengagement of burner to valve| Reengage burner and valve
Spider webs or insect nest in venturi| Clean burner/venturi tube
Burner ports clogged or blocked| Clean burner ports
Sudden drop in gas flow or reduced flame height| Overfilling prevention device
may have been activated|
- Turn control knobs to “ OFF”
- Wait 30 seconds and light grill
- If flames are still too low, reset the overfilling prevention device:
- Turn control knob(s) “ ****OFF”
- Turn LP gas tank valve to “CLOSED”
- Disconnect regulator
- Turn control knobs to ****(HIGH)
- Wait 1 minute
- Turn control knobs to “ OFF”
- Reconnect regulator and leak check connections, being careful not to fully open valve
- Light grill per “Lighting” section
Irregular flame pattern, flame does not run the full length of burner| Burner
ports are clogged or blocked| Clean burner ports
Flame is yellow or orange| New burner may have residual manufacturing oils|
Burn grill for 15 minutes on ****(HIGH) with the lid closed
Spider webs or insect nest in ventur| Clean venturi
Food residue, grease, etc . on burners| Clean burner
Poor alignment of valve to burner/venturi tube| Ensure burner/venturi tube is
properly engaged with valve
Flame goes out| High or gusting winds| Do not use grill in high winds
Low on LP Gas| Exchange, refill or replace LP gas tank
Overfilling prevention device may have been activated| Refer to “Sudden drop
in gas flow or reduced flame height” (see above)
Flare-up| Grease buildup| Remove and clean all grill parts per “Cleaning and
Care” section
Excess fat in meat| Trim fat from meat before grilling
Excessive cooking temperature| Adjust to lower cooking temperature
Persistent grease fire| Grease trapped by food buildup around burner system|
- Turn control knobs to “ ****OFF”
- Turn LP gas tank valve to “CLOSED”
- Leave lid in closed position and let fire burn out
- After grill cools, remove and clean all parts per “Cleaning and Care” section
Flashback (fire in burner tube(s))| Burner and/or burner/venturi tube are
blocked| Clean burners and/or burner/venturi tube
Inside of lid is peeling (like paint peeling)| Baked on grease buildup has
turned to carbon and is flaking off .| Clean all grill parts per “Cleaning and
Care” section
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>