YIDI Zigbee WIFI Radiator Actuator User Manual
- June 6, 2024
- YIDI
Table of Contents
YIDI Zigbee WIFI Radiator Actuator User Manual
Many thanks for your selection of our products and services, and also for your trust and support to us.
About App
Download “Smart life” or “Smart RM” App from Google play and App store.
- After the ZigBee gateway is configured, enter the gateway to add sub-devices, and wait for the actuator to be powered on and the system self-check is completed.
- long press enter to setting surface ,short press to choose icon, short press to enter network connected mode, then long press , flashing access network connected mode. Please refer to the gateway manual for Zigbee gateway configuration.
Product Specifications
- Power: 2* AA alkaline batteries
- Insulating condition: 0-50℃
- Display accuracy::0.5℃
- Running program: Set per 1 week as a cycle
- Probe sensor: NTC(10k)1%
- Size(mm): 53*89.5mm
- Maximum route: 4.5mm Range of temperature
- display::1~70°C
- Default range of temperature adjustment: 5~35°C
- Maximum current: 90mA
- Working environment temperature:: -10~60°C
- Thread size: M30*1.5
Displays & Buttons
No.
|
Icon
|
---|---|---
A
| Auto Mode; Holiday mode; Boost mode; Open Window function
B
| Low battery; Children lock; Zigbee connection status Auto mode period Set temperature/Advanced options Valve status
C
| Time setting interface: hour setting; minute setting
No.
| keys|
Represent
---|---|---
D
|
|
- Short press to switch manual mode and auto mode
- Long press to enter advanced settings
- Confirm key
E
|
|
- Decrease key
- Long press 3s to lock/unlock keys
F
|
|
- Increase Key
- Long press 3 seconds to start the BOOST function: turn on the BOOST fast heating mode, short press any key during operation to exit this function and return to the previous working mode
Installation and initial commissioning
After power on, the screen will show all for 3 seconds.|
---|---
Time setting: when flashing, then press ,display enter hour setting ,press or
to adjust value, press again display enter minute setting, press or to adjust
value, press again to set week, press or to adjust value, press to confirm
setting and remember time.
Note: after the actuator completes its self-check, under normal working status, if need to modify time, long press 3s access to advanced setting. And press to choose , short press enter time setting. the same as above method.
When display “Ad”, press Start system self-check, when display “1”, this is
the first step of system self-check. When Display “2”, this is the second step
for self-check, after finish self-check, If there is no fault prompt, it will
enter the normal working state. If there is a fault prompt, please handle the
fault first, otherwise it will not enter the normal working state.
E1
|
Motor fault
E2
| Sensor fault
****|
Flashing show low battery
Special Function description
Holiday mode| press 3s access to advanced settings, short press to
choose holiday mode ,then short press enter temperature setting, again short
press setting days setting, press or to adjust value. Under holiday mode,
short press to exit holiday mode.
---|---
Open Window|
- The actuator turns off the window opening function by default, if you need to
Function| use it, you can turn it on in the advanced option 2 setting [reset disable when changing the battery]
Auto mode setting
Long press about 3s access to advanced settings, short press switch to auto mode setting , short press access to auto mode setting, short press to choose which item you want, First set the auto mode to 5 means :5=5+2 days, 6 = 6+1 days, 7 = 7 days, after press to access to hour or minute setting, short press access to temperature setting. Press or to adjust value. short press choose: hour, minute, time period, and press or to adjust data, finished setting, about 10 seconds will automatic save and exist.
Period
| Default period|
Default temperature
---|---|---
1
| 6:00-8:00| 20℃
2| 8:00-11:30|
15℃
3
| 11:30—12:30| 15℃
4| 12:30—17:30|
15℃
5
| 17:30—22:00| 20℃
6| 22:00—6:00|
15℃
Advanced options
Press about 3-5s to access to advanced settings, short press until flashing, press to access to advanced options, press or to adjust value, after finish setting every time, short press to set next option, after finishing all , don’t operate, after 10s it will automatically save and exit.
No
| Item| Setting parameters|
default
---|---|---|---
1| Measuring temperature correction| -9-+9℃(Displayed as the corrected room
temperature value)| -1°C
2| Open window function parameter: temperature and running time|
- display means disable open window function, press key display 5°C means this function enable(temperature setting range: 5-25°C)
- Running time:5-60min(after enable function, press change setting)
|
3| Automatic lock if no operation more than 10 minutes| 0:Disable 1: Enable| 0
4| Setting temperature minimum limit| 1-15°C| 5°C
5| Setting temperature maximum limit| 16-70°C| 35°C
6| BOOST moderunning time| 100s-900s , Steps of 100 seconds| 300Seconds
7| View valve open status| 0-99
99 mean valve open 100%
5 mean valve open 5%
|
8| Start/stop working temperature difference setting| 0.5-1.5| 1
9| Display mode| 0: Upward display
1: Downward display
| 0
A| Control type of valve| 0: PID 1:ON/OFF| 0
B| Reset| Display 88, using or to change to 00, press to reset, The screen
will be fully displayed for 2 seconds.|