airKave AHD01M Room Air Sanitizer Instruction Manual

June 6, 2024
airKave

airKave AHD01M Room Air Sanitizer

airKave AHD01M Room Air Sanitizer-product

OVERVIEW

airKave AHD01M Room Air Sanitizer-1

  1. Function Button
    Turn ON / Hold to turn OFF | Tap to cycle modes

  2. Selection Button
    Turn ON | Tap for function options

  3. Top LED Indicator
    Mode & Power Level displays

  4. Front Out Air-vent
    Clean air exits here

  5. Back In Air-vent
    Contaminated air enters here

  6. Back Power Port
    Barrel type socket

KEY FEATURES

airKave AHD01M Room Air Sanitizer-2

  • ACTIVE SANITIZATION
    Plascide Micro-lightning process Anti-germ & VOCs technology

  • NO EXOTIC FILTERS
    No expensive, special or exotic filters required A simple fine dust filter for ease of mind

  • RAPID EFFECTIVENESS
    Where every breath counts, Sanitise within seconds

PACKAGE CONTENT

  1. airKAVE ROOM
  2. Fine Dust PM 2.5 filter (Type: E12 or H13)
  3. Air-vent Large Dust filter (Washable)
  4. Power supply adapter
  5. Manual & Warranty Card
  6. Magnetic Feet (x4)

QUICK START

Preparation before use:

  1. Plug power supply adapter into wall socket
  2. Plug barrel type connector into ROOM’s back power port
  3. Press or Button until LED indicator turns green
  4. Tap button to change sanitization power level

SAFETY PRECAUTIONS

airKave AHD01M Room Air Sanitizer-3

  1. Handle with care when transporting or moving

  2. ROOM can be damaged if dropped, burned, punctured or crushed

  3. Do not operate if damaged and / or when any parts are broken to avoid potential injury

  4. Power with the included power supply adapter only

  5. Do not operate with damaged connectors, cables or power supply adapter

  6. During operation or storage keep indoors and dry
    airKave AHD01M Room Air Sanitizer-4

  7. Do not operate if wet and / or immersed in any liquid to avoid potential injuries and/or damages to properties

  8. Do not allow infants and young children to operate unsupervised

  9. Keep magnetic feet away from infants, young children and animals as they can be choking hazards

  10. Do not insert any objects into the In or Out air-vents

  11. Do not operate without any parts attached or any panels left open

  12. Close left side panel and ensure all filters are seated correctly before operating

  13. Do not block the In or Out air-vents during operation

OPERATION GUIDE

Function Button

  1. Tap power button or menu to turn ON the ROOM.
  2. To turn OFF, press and hold power button for a few seconds.
  3. Tap power button to cycle the modes, LED will flash to different colours when cycled.

Mode Selection
Immediately after turning on, default mode is set to Manual

airKave AHD01M Room Air Sanitizer-5

Mode Indicator

LED MODE DESCRIPTION
RED OFF
WHITE MANUAL
BLUE PROGRAM
YELLOW TIMER
GREEN ECON

ِIn Manual, Timer and Program mode, sanitization power levels can be adjusted manually from the ROOM interface.
In Econ mode, sanitization power level is automatically set and cannot be manually adjusted.

Sanitization Power Levels

In Manual, Program and Timer modes, press to cycle through the power levels.
In Program mode, you can configure each schedule to a specific sanitization power level, for any time and day.
For more details, see: 7.6 Configure: Program In Econ mode, sanitization power level is automatic and cannot be manually changed during operations.

POWER DESCRIPTION
1 SILENT
2 LOW
3 NORMAL
4 BOOST
5 OFF

Sanitization Power Indicator
sanitization power LEDs are shown in GREEN. Mode LED will be shown in different colours. See: 6.3 Mode Indicator

airKave AHD01M Room Air Sanitizer-6

PANELS

Control Panel

  • On/Off – Turn the ROOM to Standby mode
  • M ode/Power Status – Display current status here
  • Modes – Switch to Manual/Timer/Program/Econ
  • Power Level – User can take manual control
  • Advance Panel – Access by “Gear” icon (Top Right)
  • Logout – Return to login page “Cross” icon (Top Left)

Switch modes to Manual, Timer, Program or ECON: Click Manual, Timer, Program or ECON button to activate. You can change to manual mode by

Advance Panel

  • Device Name – Display name of the ROOM
  • Login Password – Set custom password
  • Configure – Configure options for specific modes
  • System – Configure device settings
  • Bright – Set the brightness of the LEDs indicator
  • Reset – Apply factory default

Set new Device Name and/or Login Password:

  1. Select the ROOM name/Login Password field
  2. Enter a new alphanumeric entry
  3. Click “Apply” to set new name/password
  4. Click “Back” to return to Control Panel

Set specific options from the Configure and System group. Clicking on the button will take you to the specific panel options. LED Brightness can be set for all indicator LEDs Ranging from “Off”, “Dim”, “Normal” or “Bright”

Set Brightness:

  1. Select brightness option from drop-down menu
  2. Selection will be applied immediately

Reset – !Warning!
Selecting this option will restore all software to factory default. Please see for more details: 11.1 Troubleshooting

Configure: Timer
Timer mode automatically shutdown the ROOM within a set duration when activated. Configure the duration of the timer in hours and minute incrementation:

  1. Select hours from 00hrs to 24hrs and Select minutes from 00mins to 59mins
  2. Select sanitization power level by tapping button
  3. Click “Apply”
  4. Click “Back” to return to Advance Panel

Configure: Program
Enable PROGRAM mode from OFF mode: Press twice to select Program mode: press to cycle sanitization power level until ROOM enters OFF mode. Please see for further details: 6.4 sanitization Power Levels
Program allows ROOM scheduling for the entire week. Set time, day of the week and the sanitization power level. Please ensure the Time and Day is set to your time zone before utilising PROGRAM mode.
To configure:

  1. Select the time in hours and minutes (HH:MM am/
  2. Select the sanitization power level (Off / Silent / Low / Normal /
  3. Select the day or days (Monday to
  4. Click “Apply”
  5. Click “Back” to return to Advance Panel

Delete a schedule, click “Delete” on the far right side. 30 programs can be scheduled. For further details please go to our website for the latest manual: www.air-halo.com

System: Clock

To configure: To ensure Program mode is running correctly, set ROOM to your current time zone.

  1. Set Hours, Minutes and AM/PM
  2. Set date (DD-MM-YYYY)
  3. Click “Apply”
  4. Click “Back” to return to Advance Panel

MAGNETIC FEET

ROOM can be positioned vertically or horizontally on the right side panel.

airKave AHD01M Room Air Sanitizer-7

MAINTENANCES

Cleaning Recommendation
Before cleaning, please switch OFF & Unplug Power Supply

  • Surfaces: Slightly damp cloth
  • In/out out-vent Metal Mesh: cloth & vacuum
  • Large Dust Filter: vacuum & rinse with water (periodically)

Surfaces
Use a slightly damp cloth to wipe clean any blemish or dirt on the surface.

In & Out Out-vent Mesh
Vacuum the mesh carefully, use a cotton bud to remove dust from between the vents.

Large Dust Filter

  1. Position horizontally with left-side panel on top
  2. Lift the top side panel & gently remove large dust filter
  3. Wash clean with water & dry thoroughly before replacing
  4. Vacuum clean any dust or obstruction within
  5. Align large dust filter with “tabs” facing outwards and push down until it clicks
  6. Close the top side panel until it clicks

airKave AHD01M Room Air Sanitizer-9

Fine Dust Filter Replacement
It is recommended to replace fine filter (Type: E12 or H13) every 6 6-9 months. Before replacement, carefully vacuum around and inside the interior.
CAUTION: Do not remove Fine Dust filter without unplugging power supply first.

airKave AHD01M Room Air Sanitizer-10

To replace the fine dust filter, position with left left-side panel on top:

  1. Lift the front edge of the left -side panel
  2. Grip firmly to remove and pull out the fine dust filter
  3. Align replacement filter and push until it is flush with the opening

Fine Dust Filter Disposal
When fine dust filter is full, do not incinerate. Disposed separately from household waste.
Repair
Maintenance by user is not advised. For more details please see: 11.2 Warranty

SPECIFICATIONS

  • Model: AHD01
  • Modes: Manual / Timer / Program / ECON
  • Sanitization Power Levels: Silent / Low / Normal / Boost
  • Weight : 5kg
  • Air sanitizer: Plascide Technology
  • Recommend Usage: 250ft 250ft2
  • Supply: 100 100-220V@50/60Hz | Output: 12V 5A
  • Consumption: 60W
  • Dimension (283 x 333 x 140)mm

SERVICE & SUPPORT

Troubleshooting

airKave AHD01M Room Air Sanitizer-11 airKave
AHD01M Room Air Sanitizer-12

Hard Reset
If you have exhausted all possible solutions to fix your problem. You can perform a hardware reset to restore the factory defaults

airKave AHD01M Room Air Sanitizer-13

Warranty

  • ROOM is covered by a manufacturer guarantee and warranty
  • Self-repair and/or signs of tampering will void the warranty
  • Repairs should only be carried out by a certified person
  • Please refer to the included warranty card for more details

Support
Latest documentation, email: support@airkave.com
Please contact your local service centre: T: 800
800-873873-1038| WWW.AIRKAVE.COM COM
KAVE INDUSTRIES LLC
8605 SANTA MONICA BLVD #53476, LOS ANGELES, CA 90069

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals