Probe Replacement Instruction
-
Take out the device
-
Rotate and pull down the silicone cap along the front of the probe
|
---|--- -
Use a Phillips screwdriver to loosen the two screws here
|
---|--- -
Gently pull out the probe rod in the vertical direction until you see the cable terminal
|
---|--- -
Lift the white flip cover of the cable terminal to ninety degrees, and gently pull out the cable
|
---|--- -
Insert the cable into the terminal according to the color shown in the figure, and press down the white cable terminal
|
---|--- -
Insert the probe into the handle and fix it with screws
|
---|--- -
Pull up the silicone cap to its original position