1. Introduction
1.1 What you can do with this application
This is an application for the NFC data communications solar stopwatch
[SVAJ701] (caliber No: S064) manufactured by Seiko Watch Corporation.
Data obtained by [SVAJ701] can be checked, processed and saved as CSV files. In addition, the time of stopwatch can be adjusted, the lap time data stored in the stopwatch can be deleted, and the remaining battery level of the stopwatch can be checked.
1.2 Computer operating environment
The application is compatible with Windows®7 and Windows®8 and Windows®10. An Internet connection is required to download this application.
A dedicated communications device NFC reader [SVAZ015] (separately sold) is
required.
Use this application with the display resolution of the computer set to 1024 ×
768 or more. The resolution of the application screen is fixed at 810 × 711.
2. Preparations
The application is compatible with Windows®7 and Windows®8 and Windows®10. You
can download this application from the Seiko Watch Corporation website.
(Japanese OS version) “S06 application (Japanese)”
(English OS version) “S06 application (English)”
https://www.seikowatches.com/jp-ja/products/stopwatch/linktopc/download
When downloading the application, you can select the language (Japanese or English) that you…want to use.
-
You cannot install the application in both languages simultaneously.
For changing the language of the application, uninstall and reinstall the application. -
Select the same language as that of the OS.
If the language of the application is different from that of the OS some
characters in the application may not be displayed correctly.
For Japanese OS version, select Japanese.
For English OS version, select English.
Install the application according to the explanation on the screen.
-
An icon is created automatically on the desktop.
-
You can select a folder in which you want to save the application. Since the acquired data are saved in the same folder where the application is saved, when the folder in which the application is saved is changed due to reinstallation, etc., action such as moving the already saved data will be required.
2.2 Uninstall the application
Select the application from “Programs and Functions” in the control panel, and
follow the instructions on the screen to uninstall the application.
File name: S06 Stopwatch
-
Data stored in the computer is not deleted by this operation. To delete data stored in the computer, delete them from the folder where they are stored.
-
The icon on the desktop is deleted automatically.
2.3 Connect the NFC reader [SVAZ015] (separately sold) to the computer
Connect the NFC reader [SVAZ015] to a USB port of the computer. The green light on the top surface of the NFC reader flashes, indicating that the reader is ready for data reception.
- To cancel the connection, follow the instructions of the OS.
- The NFC reader [SVAZ015] does not guarantee connection with any NFC device other than the NFC data communications solar stopwatch [SVAJ701] manufactured by Seiko Watch Corporation.
2.4 Start/close the application
Start the application from the icon on the desktop or from the start menu To close the application, press the [Close] button on the application.
3. Operation
3.1 Explanation of the screen (Upper row)
3.1 Explanation of the screen (Lower row)
3.2 Transfer data from the stopwatch
Transfer data
Check that the NFC reader [SVAZ015] is connected to the computer, and start
the application.
Place the stopwatch in which the data you want to transfer are stored on the
NFC reader.
With a beep sound, the data not having been transferred yet are automatically
transferred to the application.
The number of lists of transferred data increases.
-
Only the data that have not been transferred yet are automatically transferred The already transferred data stored in the stopwatch can be transferred from the “Reload” menu.
-
When the stopwatch is in the following state, data are not transferred:
- When the stopwatch is measuring time;
- When data have not been defined (when data have not been saved in the stopwatch);
- When the stopwatch is in PS (Power Save) mode or SL (Sleep mode);
- When the stopwatch has not been sufficiently charged;
- When the stopwatch is not in the time setting mode or other setting modes; and
- When objects such as metals or other NFC devices are near the stopwatch.
Reload
Check that the NFC reader [SVAZO15] is connected to the computer, and press the ‘Reload” menu. Place the stopwatch in which the data you want to transfer are stored on the NFC reader. With a beep sound, all the data stored in the stopwatch are transferred to the application. After the transfer of the data, remove the stopwatch from the NFC reader.
*Only the data stored in the stopwatch can be reloaded.
- The new data that overlap the original data do not overwrite the existing data; the original data remain.
Up to 300 data of lap time in blocks are stored in the stopwatch. When the number of data exceeds 300, older data are automatically deleted. Once the data are deleted, they cannot be restored. Make sure to transfer data to the application each time a measurement is made to prevent the necessary data from being deleted.
3.3 Manage data with the application
Check data
On the calendar, select a day when the data you want to check were acquired.
The day displayed in boldface type is the day when data are registered.
On selecting a day, the data acquired on that day are displayed in the acquired data box in the order of the time of acquisition.
- The time of acquisition is linked with the time of stopwatch.
On selecting the acquired data you want to check, the details are displayed in the measurement data box, and information such as the number of laps is displayed in the information column.
Add a memo to data/add a memo to each lap With this application, you can add a memo to ‘entire acquired data and to ‘each lap of measurement data.” Double click ‘Lap Memo” or “Memo” to write a memo.
‘Acquired Data You can add a memo to the entire record. Up to 200 characters can be entered.
Example: ‘Swimming school individual medley practice record Taro June 17, 2014.”
‘Measurement Data You can add a memo to each lap. Up to 20 characters can be entered for each lap. Example: “(LAP 1) Butterfly, (LAP 2) Backstroke, (LAP 3) Breaststroke, (LAP 4) Free,” etc.
- The written memo is automatically reflected in the CSV files.
Saving data as CSV files
Data are automatically saved as CSV files. The saved CSV files can be confirmed from the “ All Data” button.
The file name is automatically created. [SSW acquisition dateacquisition start time stopwatch ID No.]
The CSV files are “Read Only” files. To process data, save the file with a different name and remove “Read Only status.
*When the original file name is changed, this application may not be able to read it. Be careful when you change the file name.
3.4 Delete data
Select data you want to delete from “Acquired Data,” and press the “Delete” button.
-
Once data are deleted, they cannot be restored. Take care not to delete the necessary data.
-
The corresponding CSV data will be also deleted and cannot be restored.
-
The data remained in the stopwatch can be reloaded from the “Reload” menu.
3-5 Check the data saved as CSV files
Press the “All Data button and check the list of CSV files.
- The file name is automatically created [SSW acquisition dateacquisition start time stopwatch ID No.]. When the original file name is changed, this application may not be able to read it. Be careful when you change the file name.
- The CSV files are “Read Only files far data protection. To process data, save the file with a different name and remove “Read Only” status.
- To open and process the CSV files, select a program to open CSV files as necessary.
3-6 Operation of the stopwatch
Synchronize the time of stopwatch to the time of computer Check “Synchronize the time of stopwatch to the time of computer on the application. When data are transferred, the time of stopwatch is synchronized to the time of computer.
Uncheck “Synchronize the time of stopwatch to the time of computer” when synchronization is not necessary.
- Synchronize me time at stopwatch to me time or oc.
- Note that correct time is not displayed if the time of computer is not synchronized to the standard time.
- Time can be set by the stopwatch alone. Far details, read the instruction manual of the stopwatch.
Delete all the data stored in the stopwatch
Make sure that the NFC reader [SVAZ015] is correctly connected to the
computer.
Press the [Stopwatch Clear] menu.
Place the stopwatch whose data are to be deleted on the reader. With a beep sound, all the data stored in the stopwatch are deleted.
- Once the data of the stopwatch are deleted, they cannot be restored. Pay careful attention when deleting the data.
- This operation does not delete the data stored in the application.
Check the remaining battery level of the stopwatch
When data are transferred, the remaining battery level of the stopwatch can be
checked.
3-7 Manage multiple stopwatches
Up to 100 stopwatches [SVAJ7O1] can be connected with this application. Each
stopwatch is identified by the ID number individually given. Tabs are
automatically created in the order of recognition by the application, enabling
data management for each stopwatch.
How to connect multiple stopwatches
To transfer data, follow the normal data transfer procedures. The ID number of the stopwatch is automatically recognized. When a new stopwatch is detected, a tab is automatically created (tabs are named in the order of recognition by the computer, like SSW-01, SSW-02, SSW-03
Since the tabs are named in the order of recognition by each computer, even when the same stopwatch is used, if the recognition order by the computer is different, the name of the tab is also different.
The stopwatch ID tab can be individually renamed by the application. Right- click the displayed tab, select ‘Rename’ and rewrite the name. Up to 20 characters can be entered.
Example: SSW-02 FQr second graders The changed name is not reflected in the CSV files. It can be displayed only when data are browsed with the application.
Delete the stopwatch
The registered stopwatch and the data acquired from that stopwatch can be deleted. Right-click the displayed tab, and select ‘Delete .° The data acquired from the deleted stopwatch will also be deleted. Pay careful attention as the deleted data cannot be restored.
4. “Data Integration” and “Data Movement”
When you want to move data stored and managed in the computer, perform ‘Data Integration” or “Data Movement” .
‘Integration” The data from the same stopwatch managed by multiple computers are integrated and managed as one.
‘Movement” All the data managed by a computer are moved to a different computer and managed.
Caution: When performing [Integration] or [Movement], make sure to backup data to protect important data. Pay careful attention when performing “Movement” in particular, since the original data stored in the destination computer will be destroyed and overwritten.
4.1 Integration
The data from the same stopwatch managed by multiple computers are integrated and managed as one.
- Start the application on the computer in which the data you want to integrate are stored.
- After selecting the tab of the stopwatch in which the data you want to integrate are stored, click the [All Data] button and open Explorer.
- Select the data (CSV files) that you want to integrate and copy it to a USB memory, etc.
- Start the application on the destination computer.
- After selecting the tab of the same stopwatch as click the [All Data] button and open Explorer. “Same’ in this case means the stopwatch of the same ‘ID number . The tab names displayed by the application are automatically assigned in the order of registration of stopwatches in the computer. Therefore, each computer may assign a different tab name to the same stopwatch. Make sure that the stopwatch has the same ID number from the file name, and select its tab. [ID number] [SSW acquisition day_acquisition start time_stopwatch ID number]
- Paste the data copied in 3. on Explorer. When there is a file with the same name, a confirmation screen will appear asking if you want to “Overwrite” the file. Be careful when selecting ‘Overwrite,’ as information such as lap memo you added with the application will be updated.
- Restart the application.
4. 2 Movement
All data managed by a computer are moved to a different computer and managed.
- Close the application on the data movement origin computer.
- Right-click the icon on the data movement origin computer, click on [Open File Location (I)] and open Explorer. The same can be performed from the start menu [All Programs] -> [SEIKO] -> right-click [S06 Stopwatch].
- Copy the following file and all the folders in the SEIKO SO6ssw folder to a USB memory, etc. SO6ssw.dat (Application system file) SSW-01 (Stopwatch data folder) SSW-02 (Stopwatch data folder)
(The number of folders differs according to the number of registered stopwatches) SSW-01 2014/07/17 19:15 11 SSW-02 2014/07/0813:51 D SO6ssw.dat 2014/07/17 19:15 • Backup the data before they are moved, as necessary.
4. Close the application on the movement destination computer.
5. Open Explorer on the movement destination computer, following the same procedure as
6. If data are stored by the application on the data movement destination computer, delete the following file and all the folders. SO6ssw.dat (Application system file) SSW-01 (Stopwatch data folder) SSW-02 (Stopwatch data folder) (The number of folders differs according to the number of registered stopwatches) ssw-o1 2014/07/08 9:30 SSW-02 2014/07(0813:51 D SO6ssw.dat 2014/07/08 14:00 ” Even if the data are not stored, delete the [S06ssw.dat] file on the movement destination.
7. Copy the data copied in
8. into the SEIKO SO6ssw folder on Explorer.
9. Restart the application.
“The tab number of the stopwatch is the number registered by the application on the movement origin computer.
5. Troubleshooting
When data cannot be transferred, check the following items are correct:
- The stopwatch is not measuring time;
- The data are defined (data are saved in the stopwatch);
- The stopwatch is not in PS (Power Save) mode or SL (Sleep) mode;
- The stopwatch is sufficiently charged;
- The stopwatch is not in the time setting mode or other setting modes;
- The NFC reader is properly connected to a USB port of the computer;
- The green light on the top surface of the NFC reader is flashing; and
- Metal desks or other NFC devices are not near the stopwatch.
Data already transferred can only be transferred from °Reload.” Data already deleted from the stopwatch cannot be transferred.
About After-Sales Service
When you contact us for information, we may ask you the name and the version
of the OS you are using and the type of computer. Please check them before
contacting us.
Please note that the specifications and the appearance of this product are subject to change without notice due to product improvements.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>