Operator Controls and Displays
On both the control panel and remote keypad the LEDs display the following
functions:
Glows steadily when mains power is present.
Shows the state of the entry/exit zone.
1 – 6 Shows the state of detector zones 1 to 6.
Glows steadily if the tamper loop is broken.
Glows when the system is unset, flashes when part is set.
The keypad on the control panel and 9427 provide the following keys:
Used to set the panel with individual zones temporarily omitted.
Used to enter programming and setting/unsetting commands.
Pressing the two PA keys (1 and 3) at the same time starts a PA alarm (if this
function is enabled in programming).
Used to set the system with a preprogrammed number of detectors omitted.
Used to start a test of the sounders and strobe.
Used to start a test of the detectors.
Used to change the user access code.
Used to enable or disable the Chime facility.
Used to read the 10-event log. When reading the log, pressing << (1) displays
earlier events, and >> (3) displays later events.
TO FULL SET
Key-in your four-digit user code (shown as ???? at left). The exit tone starts. Leave premises via the designated exit door. Exit tone stops after a preset time and the D light goes dark. Your alarm system is SET.
TO PART SET
Your alarm system may have been installed to allow you to have part of the
premises set while other areas (s) are off. To part set, the system key in 2
then ENTER, followed by your user code. Note that the part set exit tone is
usually a buzzer sound, but your system may be programmed to silent set. While
the system is partly set the D light flashes.
Note: If you enter your user code incorrectly four times in a row then the
system will raise a tamper alarm. See opposite.
TO SWITCH OFF
Full Set: Enter by the designated entry door. Entry tone starts. Go to the
control panel. Key-in your user code. The system is OFF.
Part Set: Go to the control panel. Entry tone starts.
Key-in your user code. The system is OFF.
Note: The system has a preset entry time to allow you to get to the panel.
When the entry time has elapsed your system may be programmed to give an
internal alarm for 30 seconds. At the end of these 30 seconds, the system
gives a full alarm (external sounder). Key in your user code to cancel the
alarm.
IF A ZONE LIGHT GLOWS WHILE SETTING
If, during setting, the sounder gives an interrupted tone and a zone light
glows, then a detector is being triggered (maybe a door or window is open).
Key in your user code to stop the tone.
Check the indicated zone(s) and if possible correct the cause of the alarm.
Try setting the system again.
If the fault persists, call your alarm installer.
If the Entry/Exit light glows, the exit door may be open. Leave the premises
and close the door. The interrupted tone should change to a steady tone when
the door is closed and the system then sets as normal.
TO OMIT A DETECTOR
You may need to temporarily set the system with one or more detectors omitted.
Key in the zone number followed by OMIT for all the zones you want to omit and
then key in your user code. The system flashes the light(s) of the omitted
zone(s) during the exit time and then sets. Note that you cannot omit a panic
or fire zone, or the EE zone.
The system will not raise an alarm if any omitted detector is triggered during
this setting cycle. The system will reinstate the detector(s) and set normally
the next time you set the system.
TO SWITCH CHIME ON OR OFF
Key in 7 then ENTER, followed by your user code to switch Chime on or off. When Chime is on, the internal sounder chimes when the chime zones operate. Note that the Installer must program your chime zones.
KEYPAD PA
Your system may be programmed to allow you to start a Panic Alarm from the keypad (ask you Installer). If so, then press keys 1 and 3 together to start a Panic Alarm.
AFTER AN ALARM
To switch the bells off: Key-in your user code.
The sounders will stop and the zone light(s) for the detectors that triggered
the alarm will glow.
Reset system: You must reset the system before it can be used again. Key in
your access code again.
All the zone lights should go off. The system is now ready for use.
Fire Alarm: The fire alarm is a two-tone siren note from the internal sounder.
Leave the building immediately and call the Fire Brigade. Do not go back into
the building until it is safe to do so. Switch the alarm off and reset the
system as described above. If you have trouble resetting the system make sure
that the fire detector is not being triggered Reset any panic buttons gered.
Tamper or Panic Alarm: If you hear the internal sounder when the system is off
then look at the control panel:
If the Tamper light glows then key in your user code to stop the sounder. Call
your alarm installer for service.
If the Panic light (zone 6) glows then deal with the cause of the alarm first. Next, reset the panic button, then switch the alarm system bells off and reset the system (see above).
TO TEST BELLS
Make sure system is unset before starting the test. Key in 4 then ENTER followed by your user code. The internal sounders will operate for three seconds and then the external sounder and strobe will operate for three seconds.
TO WALK TEST
Key in 5 then ENTER, followed by your user code.
The internal sounder gives a steady tone.
Open and close the Exit/Entry zone and zones 1 to 4. (Open and close zone 5 if
it is NOT a fire zone, and zone 6 if it is NOT a panic button.) Each time you
open a zone, the internal sounder gives a pulsing tone.
You cannot test the ‘Tamper Circuits’ without creating an alarm condition.
Similarly, a panic button will always cause a full alarm.
To stop the walk test, key in your access code.
TO READ THE LOG
The system keeps a log of the last ten alarm or tamper events. To read the log key in 8 then ENTER followed by your user code. The system switches on the zone or Tamper lights to show you the most recent event. If you want to see earlier events then press ‘<<‘ (the 1 key). To see more recent events press ‘>>’ (the 3 key). The keypad gives a short tone when you reach either end of the log. To leave the log press OMIT or ENTER.
TO CHANGE YOUR USER CODE
Your system provides two separate four-digit user codes. When the system is
new, the user codes are “1234” and “0000”. Change the “1234” user code
immediately to a number that only you know. The new code can be any four-digit
code you choose EXCEPT “0000”.
The “0000” user code is inactive and will not operate the system. To activate
the second user code change the “0000” to another four-digit number. To
inactivate the second user code again, change it back to “0000”.
DO NOT use the same number for both user codes.
Zone Descriptions
Entry-Exit Zone:
Zone 1:
Zone 2:
Zone 3:
Zone 4:
Zone 5:
Zone 6:
Installer Name:
Day Tel:
Night Tel:
9448+ and 9448ES Hard-Wired Control Panel User Guide.
© Scantronic Ltd. 2001
Every effort has been made to ensure that the contents of this book are
correct, errors and omissions excepted. However, neither the authors nor
Scantronic accepts any liability for loss or damage caused or alleged to be
caused directly or indirectly by this book. The contents of this book are
subject to change without notice.
Printed in China.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>