- Safety instructions
- Device components
- Intended use
- Product characteristics
- Operation
- Fitting and electrical connection
- App functions
- Commissioning without app
- DANGER!
- Reset device
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NEXENTRO 57006000 Zigbee Dimming Actuator Mini Instruction
Safety instructions
To avoid possible damage, read and follow the following instructions:
Installation only by persons with sound knowledge and experience in the following areas: – 5 safety regulations and standards for the installation of electrical systems
- Selection of suitable tools, measuring devices, installation materials and, if necessary, personal protective equipment
- Installation of the installation material
- Connection of devices to the building installation under consideration of local connection conditions
Improper installation endangers your own life and the lives of users of the
electrical system and there is a risk of serious damage to property, e.g.
through fire. You are at risk of personal liabil-ity for personal injury and
damage to property.
Contact an electrical contractor!
Even a lamp that is visibly switched off is permanently supplied with mains
voltage. Therefore, switch off the circuit breaker before replacing the lamp.
Otherwise there is a risk of electric shock when touching live parts.
Fire hazard. For operation with inductive transformers, each transformer must
be fused on the primary side in accordance with the manufacturer’s
instructions. Only safety transformers ac-cording to EN 61558-2-6 may be used.
Risk of destruction if the set operating mode and load type do not match. Set
correct operating mode when connecting or exchanging the load. The device must
not be used in connection with consumers that could lead to danger to life or
limb or damage to property, e.g. heaters or electrical machines. Read the
instructions in full, observe them and keep them for future reference.
Device components
- Dimming actuator mini
- Terminals
- Button Prog.
- LED
Intended use
- Zigbee actuator to switch and dim lighting
- Zigbee transmitter to operate Zigbee-compliant lamps, luminaires, dimming and switch ac-tuators
- Operation of Zigbee-compliant transmitters or connected push-buttons (normally open contact)
- Use in conjunction with Zigbee gateways from different manufacturers
- Mounting in appliance box according to DIN 49073 with a suitable cover
Product characteristics
- Zigbee Certified Product
- Device works according to the leading edge phase control or trailing edge phase control principle
- Automatic or manual setting of the dimming principle suitable for the load
- Display of the set operating mode by means LED
- Switch-on via bulb-preserving soft start
- Switching on with last saved brightness
- Minimum brightness can be saved permanently
- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
- Electronic over-temperature protection
- Operation without neutral conductor possible
- Input to connect a push-button
- Assigning the input to other Zigbee devices via app
- Parameterising via app
- Updating via app
Operation
Operation with connected push-button Switching the light
Press the push-button briefly: Light switches off or light switches on at
the last brightness level set.
Adjusting the brightness
Long press on the push-button: Adjust the brightness. The dimming direction
is changed with each new long actuation.
Switch light on with minimum brightness
Long press on the push-button: Light switches on at minimum brightness and
gets brighter.
Transmitter function
Additional Zigbee lamps or devices for controlling lighting can be connected
to the actuator. This function is set with the NEXENTRO Config App. The
devices are then operated in the same way as the actuator when a push-button
is pressed.
Radio operation
The operation is done with Zigbee transmitters or Zigbee gateways that comply
with Zigbee Standard 3.0. The scope of functions and the type of operation
depends on the transmitter or gateway used.
Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched. Electrical shocks can be fatal. Before carrying out work on the device or load, disengage all the corresponding cir-cuit breakers, secure against being switched on again and check that there is no voltage! To ensure good transmission quality, keep a sufficient distance from any possible sources of in-terference, e.g. metallic surfaces, microwave ovens, hi-fi and TV systems, ballasts or trans- formers.
Dimming actuator mini
Push-button, NO contact
Figure 3: Clampable conductor cross-section
Connect 600 Watt LED lamps or compact fluorescent lamps at most per 16 ampere
circuit breaker. When connecting transformers, observe the data of the
transformer manufac-turer.
The actuator takes into account the different electronic characteristics of
most dimmable LED lamps on the market. However, it cannot be guaranteed that
in individual cases the desired results may not be achieved.Operation without
neutral conductor possible. Lit push-buttons must have a separate N terminal.
- Make the connection according to the connection diagram. In doing so, note the clamp-able conductor cross-section (Figure 3).
- Insert the actuator in the appliance box in such a way that the Prog. button and status LED are visible. The light can be switched by briefly pressing the Prog. button.
- Mount a suitable cover or push-button.
- Perform commissioning.
Reset the overheating protection / short-circuit protection
If the electronic overheating or short-circuit protection has been
triggered, disconnect the actu-ator from the mains. After cooling the actuator
is ready for use again. Commissioning with app
The requirement for commissioning via app is a mobile end device (smartphone,
tablet) with Bluetooth interface, running the Android or iOS operating system.
The app guides you step by step through the commissioning process.
Download and install the NEXENTRO Config App from the App Store (iOS) or Google Play Store (Android).
App functions
- Joining an existing network
- Setting up your own network
- Assigning device names
- Setting device parameters: operating mode, minimum brightness
- Connecting the actuator with Zigbee transmitters or gateways
- Connecting the input to Zigbee devices
- Displaying the switching status: On, Off, brightness value
- Displaying device information: Device type, software version, hardware version
- Performing a software update
- Resetting to default setting
- Operating the actuator for test purposes
Coupling and registering new devices
The coupling of new devices is always only possible for approx. 1 minute after mains voltage return to prevent unauthorised access. Coupling is possible at any time with devices registered in the app.
- Couple the mobile end device via Bluetooth with the device.
- Add the new device to the list of registered devices.
- Assign a device name.
Performing Zigbee configuration
The actuator can be added to an existing Zigbee network to control the Zigbee devices present there or to be controlled by transmitters present there. If no Zigbee network exists, the actuator can create its own
Zigbee network by calling it in the app. Adding an actuator to the Zigbee network of a gateway
With certain gateways, adding to a network is done via the Touchlink function
- Start search mode for new devices in the Zigbee system. The function call depends on the gateway, e.g. “Search devices”.
- Select the Join Network function. The actuator is displayed in the app of the gateway.
The NEXENTRO Config App displays all available Zigbee devices to which the actuator can be connected.
- Further actions in the NEXENTRO Config App follow. Using the actuator without an existing Zigbee network, the actuator forms its own network
- Select the Create Network function. The NEXENTRO Config App displays all available Zigbee devices to which the actuator can be connected.
- Further actions in the NEXENTRO Config App follow. Connecting the actuator to devices via Touchlink
To connect the actuator to another Zigbee device via Touchlink, e.g. a hand- held transmitter or gateway, Touchlink must be first activated on the actuator. Requirement: The distance between the devices to be connected is 10 to 50 cm.
- Select the Touchlink function. The actuator is ready to be connected to a device via Touchlink.
- Trigger Touchlink on the other Zigbee device. The actuator is connected to the device.
- Further optional actions in the NEXENTRO Config App follow.
Commissioning without app
A simplified commissioning can also be carried out without the app. Prerequisite: The actuator is in the default setting or the assignment to a Zigbee network has been deleted.
- Open the network of the gateway, see gateway app.
- Switch on mains voltage. The actuator searches for the gateway’s Zigbee network for 1 minute. The light flashes two times, the actuator has found the network and joined it. The actuator is displayed in the app of the gateway.
- If the actuator is operated without a gateway, connect the actuator to a transmitter via Touchlink within 5 minutes after switching on the mains voltage. A more detailed configuration can only be carried out with the NEXENTRO Config App.
Setting operating mode and minimum brightness with the Prog. button
DANGER!
Mortal danger of electric shock. The following work must be carried out under mains voltage and therefore may only be carried out by an electrician! Only use insulated tools for the work! Cover up live parts in the working environ- ment. Operating mode: Universal, R,L,C,LED (factory setting) – Automatic calibration to the load, dimming principle, trailing edge phase control, leading edge phase control or LED leading edge phase control Operating mode: LED trailing edge phase control, Loads can be dimmed according to the trailing edge phase control principle. The connection of inductive transformers is not permitted.
Operating mode: LED leading edge phase control, |
- Loads can be dimmed according to the leading edge phase control principle.The connection of inductive transformers is not permitted.
Figure 4: Assignment of LED colour to dimming principle Precondition: Load is switched off.
- Press the button Prog. (3) until LED (4) lights up. The current operating mode is displayed.
- Keep briefly pressing button Prog. (3) until the necessary operating mode is selected. The LED (4) lights up in the colour of the selected operating mode (Figure 4).
- Press the button Prog. (3) for longer than 1 second and keep it pressed. On changing the operating mode to Universal, the first task is the calibration to the load. Keep the Prog. button (3) pressed. LED (4) flashes. Light switches on at the lowest brightness and slowly becomes brighter to set the minimum brightness.
- Once the desired minimum brightness is reached, release the button Prog. (3). In the low-est dimming position, a lamp light must be visible.
- Optionally change the minimum brightness again: Press the button Prog. (3) for longer than 1 second. Light switches again to the lowest brightness and slowly becomes brighter.
- Save the settings: Press the button Prog. (3) for less than 1 second or do not press for 30 seconds. The LED (4) goes out. LED (4) lights up in the colour of the set operating mode, operating mode and minimum brightness are set.
Reset device
Deleting assignment to the Zigbee network and Bluetooth coupling
Switch off the supply voltage to the device four times in quick succession and switch it on again. The pause between switching operations must be less than two seconds. The actuator acknowledges the deletion of the network assignment and the Bluetooth coupling to mobile end devices by flashing the light twice. Restoring the device to factory settings The device deletes the assignment to a network and all connections to Zigbee lamps and devices. The operating mode Universal is set. Alternatively, the device can also be reset with the NEXENTRO Config App.
DANGER!
Mortal danger of electric shock. The following work must be carried out under mains voltage and therefore may only be carried out by an electrician! Only use insulated tools for the work! Cover up live parts in the working environ- ment.
Precondition: Load is switched off.
■ Press the Prog. button (3) for longer than 20 seconds. After approx. 20
seconds, the LED flashes rapidly alternately red and green.
■ Within 10 seconds, release the button and actuate it briefly once again. The
LED flashes more slowly alternately red and green, the device is reset to the
default settings and is restarted. After resetting the device to the default
settings or deleting the Bluetooth coupling, the device must be removed from
the NEXENTRO Config App. On iOS equipment, the device also has to be removed
from the list of paired Bluetooth devices (Settings/Bluetooth). Otherwise, re-
pairing will not be possible.
Rated voltage AC 230 / 240 V ~
Mains frequency 50 / 60 Hz
Standby power max. 0.2 W
Power loss max. 1.7 W
Ambient temperature -5 … +45 °C
Storage/transport temperature -25 … +70 °C
Dimensions (LxWxH) approx. 48 x 45 x 20 mm
Connected load at 35 °C, see Figure (Figure 5)
Mixed load
capacitive-inductive
-
Power specifications including transformer dissipation.
-
Operate inductive transformers with at least 85% nominal load.
-
Ohmic-inductive mixed load: Max. 50% proportion of ohmic load. Otherwise, an incorrect measurement is possible.
-
Operation without neutral conductor: Minimum load 50 W. Does not apply to loads with HV-LED lamps.
-
Power reduction
per 5 °C in excess of 35 °C
-5%
when installed in wooden or dry construction walls
-15%
when installed in multiple combinations
-20% -
Total line length
pwr cable max.
100 m
Extension max.
50 m -
Zigbee
Communication protocol
Zigbee 3.0 (router)
Radio frequency
2.400 … 2.483 GHz
Transmission capacity
1 mW -
Bluetooth
Radiofrequency
2.402 … 2.480 GHz
Transmission capacity max.
2.5 mW, Class 2
Transmitting range
typ. 10 m
Troubleshooting
Connected LED lamps switch off in the lowest dimming position or flicker
Cause: The set minimum brightness is too low.
Increase minimum brightness.
Connected lamps do not switch on in the lowest dimming position or only
after a delay
Cause: The set minimum brightness is too low.
Increase minimum brightness.
Connected LED lamps flicker or buzz, proper dimming not possible, device
buzzes
Cause 1 : Lamps are not dimmable.
Check manufacturer’s instructions.
Exchange lamps for another type.
Cause 2: Operating mode (dimming principle) and lamps do not optimally
match.
Check operation in another operating mode, reduce connected load as well if necessary. Set the operating mode manually. Exchange lamps for another type.
Cause 3: Actuator is connected without neutral conductor. If possible,
connect neutral conductor or insert compensation module parallel to the lumin-
aire, otherwise exchange lamp for another type. Check operation in another
operating mode, reduce connected load as well if necessary. Set the operating
mode manually. Exchange HV-LED lamps for another type. The actuator switches
the load off briefly and then on again. Cause: short-circuit protection has
tripped but now there is no longer a fault. The actuator has switched off and
cannot be switched on again.
C ause 1: overheating protection has tripped.
Disconnect the actuator from the mains by switching off the circuit breaker.
LED trailing-edge phase control: Reduce the connected load. Exchange lamps for
another type. LED leading edge phase control: Reduce the connected load. Check
operation in the LED trailing edge phase control setting. Exchange lamps for
another type. Let the actuator cool down for at least 15 minutes. Switch
circuit breakers and dimmer on again. LED trailing edge phase control: Check
operation in the LED leading edge phase control setting, reduce connected load
as well if necessary. Exchange lamps for another type.
Cause 3: short-circuit protection has tripped.|
Disconnect the actuator from the mains by switching off the circuit breaker.
Eliminate short-circuit. Switch circuit breakers and dimmer on again. Short-
circuit protection is not based on a conventional fuse, no metallic separation
of the operational current.
Cause 4: load failure.
Check load, replace a light bulb. For inductive transformers, check primary
fuse.LED lamp is dimly lit when the actuator is switched off
Cause : the LED lamp is not optimally suited for this actuator. Use a
compensation module. Use another type of LED lamp or an LED lamp of another
manufacturer.
Declaration of conformity
Insta GmbH hereby declares that the radio system type art. no. 57006000 meets
the directive 2014/53/EU. You can find the full article number on the device.
The complete text of the EU De-claration of Conformity is available under the
Internet address:
www.insta.de/instastorefront/services/downloads
Warranty
We reserve the right to make technical and formal changes to the product in
the interest of technical progress.
We provide a warranty as provided for by law.
Please send the unit postage-free with a description of the defect to our
central customer ser-vice office:
Insta GmbH
Service Center
Hohe Steinert 10
58509 Lüdenscheid
Germany
Insta GmbH
Postfach 1830
58468 Lüdenscheid
Germany
Telefon +49 (0) 2351 936-0
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>