TRIPLETT AM250 Thermo-Anemometer + Psychrometer User Manual
- June 6, 2024
- TRIPLETT
Table of Contents
User Manual
AM250
Thermo-Anemometer + Psychrometer
Introduction
Congratulations on your purchase of the Triplett AM250 Anemometer/Psychrometer. The dual display indicates Air Velocity and Humidity, Dew Point, Ambient Temperature, or Temperature with the wind-chill factor. With careful use, this meter will provide years of reliable service.
Meter Description
- Vane impeller
- Temperature sensor
- Relative Humidity sensor
- LCD display
- ON/OFF, HOLD key
- UNITS, MODE key
- Battery compartment (on rear)
- Swivel handle and storage case
- Lanyard (Neckstrap)
- Impeller set screw (on the rear of a meter)
- Tripod mounting hole
Operation
Turning the meter ON and OFF
Press the ON/OFF/HOLD button to turn the meter ON
Press and hold the ON/OFF/HOLD buttons for approx. 3 seconds to turn it OFF
The meters Auto Power OFF feature turns the meter OFF after 20 minutes of
inactivity
Change the lower display parameter
With the meter ON, press and hold down the ON/OFF/HOLD button While
continuing to hold the ON/OFF/HOLD button, press the UNITS/MODE button
repeatedly to step through Temperature (oF/oC), Humidity (RFt%), Dew Point
(TD), & Temperature with wind-chill factor (WCI). Note that the center display
is Air Velocity.
Change the Air Velocity unit of measure
Turn the meter OFF. Press and hold down both buttons until the display
turns on and begins blinking then release both buttons Press the UNITS/MODE
button repeatedly to step through the units (see specs for list) After 5
seconds the meter switches back to normal operation mode automatically
Select temperature units (oC or oF)
Turn the meter OFF first. Press and hold down both buttons until the
display turns on and begins blinking then release the buttons Press both
buttons momentarily to change temperature units After 5 seconds the meter
switches back to normal operation mode automatically
Taking Measurements
Position the meter so that the airflow enters the meter vane from the rear
of the meter (opposite side of front panel logo). A tripod mount is located on
the bottom of the meter.
Max Hold
Max Hold represents the highest measurement taken since the meter was
turned on Press the UNITS/MODE button to display the Max reading (MAX icon
appears)
Press the UNITS/MODE button repeatedly to step through to the normal operating
mode
Average mode
5 or 10 reading averages can be displayed in the Average Mode.
Press UNITS/MODE 3 times for 5 reading averaging or 4 times for 10 readings To
exit this mode, press the UNITS/MODE button until the icons on the left
disappear
Data Hold
Data Hold freezes the most recent displayed reading
Press and hold the ON/OFF/HOLD button to activate Data Hold
As long as the ON/OFF/HOLD button is held the reading will remain on the LCD
Specifications
Measurement | Range | Resolution | Accuracy (% of reading) |
---|---|---|---|
MPH (Miles per hour) | 2.5 to 44.7 MPH | 0.2 MPH | ± (3% + 0.4 mph) |
km/hr (kilometers per hour) | 4.0 to 72.0 km/h | 0.7 km/h | ± (3% + 1.4 km/hr) |
Knots (nautical miles per hour) | 2.1 to 38.9 knots | 0.3 knots | ± (3% + 0.6 |
knots)
m/sec (meters per second)| 1.1 to 20.0 m/s| 0.1 m/s| ± (3% + 0.2 m/s)
ft/min (feet per minute)| 216 to 3936 ft/min| 20ft/min| ± (3% + 40 ft/min)
Beaufort force| 1 to 8 BF| 1 BF| ± 1
Temperature| 0 to 122°F (-18 to 50°C)| 0.1°F/C| ± 1.8°F (± 1°C)
Relative Humidity| 10 to 95%| 1%| ±5%RH
Dew Point| 32 to 122 °F (0 to 50°C)| 0.1°F/C| ± 3.6°F (2°C)
General Specifications
Display | Dual LCD with low battery and multifunction indicators |
---|---|
Sensors | Sapphire bearing, non-corrosive vane for air velocity; Precision |
thermistor for temperature measurements
Average Mode| Choice of 5 or 10 reading averaging (2-second factory default)
Max and Data Hold Displays| Max recalls the highest reading; Data Hold freezes
the display
Sample time| 1 reading per second for air velocity and temperature (1 reading
per 15 seconds for humidity with 2-second updates)
Water-resistant| To 3′(1m)
Operating conditions| 5 to 122°F (-15 to 50°C) / < 80% RH
Power supply| Lithium battery (CR-2032 or equivalent) / 400 hour battery life
Dimensions / Weight| Instrument: 133 x 70 x 19mm( 5.25 x 2.75 x 0.75″) Vane:
1′(24mm) diameter /3 oz.(95 g)
Maintenance
Battery Replacement
The AM250 has a low battery indicator (battery symbol). Important: Turn the meter off before opening the battery compartment. Using a coin, turn the battery compartment cover CLOCKWISE to remove it. Once opened, observe the position of the battery, placing the new one in the same position. Secure the battery compartment cover and dispose of the lithium battery in accordance with local, state, or national disposal codes.
All EU users are legally bound by the Battery Ordinance to return all used batteries to community collection points or wherever batteries/accumulators are sold.
Disposal of household trash or refuse is prohibited.
Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle
Other Battery Safety Reminders
Never dispose of batteries in a fire. Batteries may explode or leak.
Never mix battery types. Always install new batteries of the same type.
Impeller Replacement
Remove the set screw next to the impeller assembly (on the rear of the meter).
Twist the impeller assembly counter-clockwise to the OPEN position and remove
it.
Install impeller by inserting & twisting the new impeller assembly clockwise
Tighten the set screw.
CFM Measurements
Measure the area of the duct using the diagrams below for rectangular and
circular ducts (If the duct measurements are made in inches, divide the inches
by 144 to get the area in square feet).
Plug the area value (in square feet) in the cubic equations below. Note that
the air velocity must be plugged into the cubic equations also.
CFM (ft3/min) = Air Velocity (ft/min) x Area (ft2)
CMM (m3/min) = Air Velocity (n /sec) x Area (m2) x 60
Warranty
Triplett / Jewell Instruments extends the following warranty to the original purchaser of these goods for use. Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of (1) one year from the date of purchase. This warranty does not apply to any of our products that have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as, in our sole judgment, to injure their stability or reliability, or which have been subject to misuse, abuse, misapplication, negligence, accident or which have had the serial numbers altered, defaced, or removed. Accessories, including batteries, are not covered by this warranty
Copyright © 2021 Triplett
www.triplett.com
Documents / Resources
|
TRIPLETT AM250 Thermo-Anemometer +
Psychrometer
[pdf] User Manual
AM250, Thermo-Anemometer Psychrometer, AM250 Thermo-Anemometer Psychrometer
---|---
|
TRIPLETT AM250 Thermo Anemometer +
Psychrometer
[pdf] User Manual
AM250, Thermo Anemometer Psychrometer
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>