Electrolux WE451KX-DWB2 Electric Water Heater
PARTS IDENTIFICATION
- Front Cover
- LED Indicators
- Earth LED Indicator
- Power/ELCB LED Indicator
- Test / Reset Button
- Face Panel
- Pump Button*
- Temperature Control Knob
- 3 in 1 Stop Valve
- Stop Valve Lever
- Flow Regulator Valve Adjustment
- Built-in-Filter
- Mesh Filter
- Rail Support
- Handshower
- Adjustable Shower Holder
- Slider Rail
- PVC Hose
- Soap Tray
- Heater Bas
- Terminal Block
- Thermostat (Double-Action)
- Heater Tank
- PCB Board (Test & Reset
- VR Board
- Main/ELCB Board**
- Water Outlet Connection
- AC Pump*
- TRIA
- Reed Switch Assy***
- Water Inlet Connection***
- SMPS PCB Board
- D.C. Silent Pump*
- Rating Label
- Pump Board
- Shower Bracket Holder
Fig 1.
Slide Bar Accessories (5 Sprays – Vietnam only / 5 Sprays – EWE451KB-DWG2
only)
Slide Bar Accessories (Single Spray – Thailand, Indonesia, Philippines, and
Malaysia pump model) Bracket Accessories (Single Spray – Malaysia standard
model)
SAFETY INFORMATION
WARNING!
2.1 Products manufactured by Electrolux are safe provided they are installed,
used and maintained in good working order in accordance with our instructions
and recommendations. Always refer to this manual if you have any doubt.
2.2 The Electric Water Heater must be earthed. Improper grounding could cause
electrical shock.
2.3 If any of the following conditions occur as shown below, immediately
switch off the power supply and contact the Electrolux Consumer Care Center.
Never attempt to repair the Electric Water Heater yourself:
- If the Electric Water Heater begins to make an odd noise, smell or smoke.
- If ELCB trips and Electric Water Heater Indicator does not light up.
- Water temperature cannot be controlled.
- If the Electric Water Heater shows signs of a distinct change in performance.
- If water leaks from inside.
2.4 If the Red ( POWER) Indicator does not go off when you turn off the
water, switch OFF the mains supply and contact Electrolux Consumer Care Centre
for repair service.Special skill is required for repairing. NEVER try to
repair the unit by yourself.
2.5 For the Pump Model, it is highly recommended to connect the Water Inlet
Connection to the tank storage supply, otherwise it may cause damage to the
Pump Motor.
2.6 When the Electric Water Heater is used by someone such as a child, elderly
person, sick person and physically handicapped person, the person concerned is
kindly requested to pay attention and check the shower temperature by hand
from time to time. The user is advised to test and adjust the water
temperature before using it.
2.7 During lightning/thunder, switch off the power supply to the Electric
Water Heater in advance to protect the Electric Water Heater against possible
damage.
2.8 The earth continuity conductor of the electrical installation must be
effectively connected to all exposed metal parts of other appliances and
services in the room, which in the Electric Water
The heater is to be installed to conform to local regulations and ensure
proper earthing/grounding for ELCB to be effective.
2.9 WARNING : Metallic / chromed hose and conductive control valve shall
not be used.
NOTE: When removing the Electric Water Heater from the package, a small
amount of water may be found inside. This is normal as the Electric Water
Heater is tested during the manufacturing process.
CAUTION!
2.10 Installation must be carried out by a qualified personnel and in
compliance local authority regulations.
2.1 1 This Electric Water Heater must be permanently connected to the direct
main line supply. A plug and socket is not recommended to be used.
2.12 For the correct size of wire conductor corresponding to different
electrical loadings, please refer to Table 1.
2.13 This Electric Water Heater operates at a minimum water flow rate of 2.0
litre/min
(2.2 ℓ/Min for 4.8kW & 2.5 ℓ/min for 6.0kW model only) and maximum working
pressure of 6 bars. For direct connection from the water tank, the Electric
Water Heater must have an installation minimum 1.0m below the water tank.
2.14 The Electric Water Heater will not function if there is insufficient water
flow (min 2.0 litre/min / 2.2 ℓ/Min for 4.8kW & 2.5 ℓ/min for 6.0kW model only)
to trigger the flow switch.
2.1 5 The built-in ELCB will automatically cut off the power supply in case
there is a current leakage over 15mA.
2.16 The thermostat will automatically cut off the power supply if it has
sensed an abnormal rise in water temperature.
ELECTRIC WATER HEATER UNIT INSTALLATION
3.1 Select a suitable position in the bathroom.
3.2 Remove the screw (A) at the bottom of the Electric Water Heater. (Fig. 2)
3.3 Remove the Front Cover from the bottom and then lift up the front cover.
3.4 Mark 3 Screw points of the Heater Base on the wall. The Electric Water
Heater position should be 1.5m above the bathroom floor. (Fig. 2)
3.5. Slider Bar Accessories: Mark 2 screw points of the Slider Rail beside the
Electric Water Heater. It is recommended that the top of the portion is in
level with the top of Electric Water Heater. (Fig. 3 & 3a) Bracket
Accessories: Open the Shower Holder cover, mark 2 screw point of the Shower
Holder beside the Electric Water Heater. It is recommended that the top of the
portion is in level the top Electric Water Heater. After screw, the Shower
Holder put back the shower holder cover. (Fig. 3b)
3.6 Use 6mm diameter drill and make the wall plug holes in the depth of 34mm ,
for mount the Electric Water Heater.
3.7 Insert the wall plugs and mount the Electric Water Heater firmly in
position with the screws provided.
3.8 Insert the Shower Holder and Soap Tray into the Slider Rail.
3.9 Insert the Rail Bracket to both end of the Slider Rail Bar.
3.10 Remove the cap from the Rail Bracket and screw the Bracket to marked
position.
Replace the cap. (Fig. 3)
RAIL BRACKET COVER & CAP DISMANTLE STEPS FOR SLIDER BAR ACCESSORIES
PLUMBING PROCEDURE
CAUTION!
This Electric Water Heater is a single point system and the “Water Outlet” can
only be fitted to the Hose and Handshower set provided.
MUST NOT TO CONNECT CONTROL VALVE OR FITTING CAN BE FITTED TO THE WATER OUTLET.
4.1 Connect the 3 in 1 Stop Valve to the Water Inlet with washer. Use correct
tools to tighten and be careful not to over tighten and damage the plastic
nut.
4.2 Connect the incoming water piping to the 3 in 1 Stop Valve (1/2” BSP).
Make sure to put the Mesh Filter between 3 in 1 Stop Valve and incoming water
piping.
4.3 If in any case, the 3 in 1 Stop Valve is not used or omitted, make sure to
put the Mesh Filter between the Electric Water Heater inlet pipe and incoming
water pipe.
4.4 Turn on the water mains to drain out all plumbing dirts before connecting
the water supply to the Electric Water Heater, the water supply to the
Electric Water Heater must be free from mud and dirt. Always KEEP the water
supply to the Electric Water Heater free from mud and dirt at all time during
usage.
4.5 Connect the Hose and Handshower to the outlet of Electric Water Heater, be
sure to put in the Washer in between the connection. (Fig. 2)
4.6 Hook the Handshower to the Slider Rail Shower Holder and adjust to your
ideal position.
4.7 Check if any water leakage.
4.8 Do not use sealing tape during piping installation.
WARNING!
4.9 THE WATER INLET AND OUTLET MUST BE INSTALLED CORRECTLY, OTHERWISE ELECTRIC
WATER HEATER WILL NOT FUNCTION
4.10 DO NOT APPLY PLUMBING CEMENT ON CONNECTION. WHENEVER NECESSARY, USE ONLY
THREAD OR SEALING TAPE.
ELECTRICAL INSTALLATION
WARNING!
5.1 This Electric Water Heater must be earthed. Improper grounding could cause
electrical shock.
5.2 Remember to SWITCH OFF the power supply before carrying out any electrical
work.
5.3 Refer to TABLE 1 for the correct cable size.
5.4 Use double insulation cable of over 2.5mm² for 2.4kW, 3.5kW 3.8kW, 4.5kW
4.8kW models and 4mm² for 3.6kW and 6.0kW model.
5.5 Lead the power cable from MCB to a “ON/OFF’’ double pole Linked Switch
having a contact separation of at least 3mm in all poles outside the bathroom,
then lead a cable to the terminal block inside the Electric Water Heater (Fig.
4)
PROCEDURE
5.6 Insert the wall embedded cable through Side Entry ‘A’ by cutting a hole at the source cord rubber holder and lead the cable to Cable Bracket ‘B’. (Fig. 6)
5.7 Connect the cable as following: (Fig. 5)
BROWN or RED –LIVE (L) BLUE or BLACK –NEUTRAL (N) GREEN or GREEN/YELLOW –EARTH
( )
5.8 Clamp the cable to the correct position. The technician need to confirm
the wire before installation. CHECK IF THE WIRING CONNECTION IS CORRECT and
replace the cover.
5.9 When putting back the Front Cover, please take note of the procedure shown
below :
- Ensure the position is correct, turn the Temperature Control Knob Insert to OFF position as shown in Fig.A (At the Heater Base)
- Install the Front Cover,turn the Temperature Control Knob to OFF position to align with the VR shaft as shown in Fig.B (At the Front Cover)
5.10 Fix the Temperature Control Knob and screw ‘A’ (Fig. 2).
ELECTRICAL INSTALLATION (CONT’D)
METHOD OF ALIGNMENT WHEN REPLACING FRONT COVER
TABLE 1 – CABLE SIZE TABLE
TEST RUN
7.1 Turn on the water supply and 3 in 1 Stop Valve, the water will flow
through the Handshower.
7.2 Switch on the power supply. The 3 LED Indicator light shall run ON/OFF 3
times in sequences to indicate the set are self checking. If the Electric
Water Heater is not earthed properly, the Earth Led indicator light will OFF,
during usage or standby. Earth Led indicator light also OFF if Live & Neutral
reverse connection.
7.3 Turn the Temperature Control Knob to ‘ON’, the Red indicator light (HEATER
POWER) will turn on, (ELCB/Power Led indication are combine Led indicator
light- ELCB is GREEN & Power is RED) hot water will flow out within a few
seconds. The more Temperature Control Knob being turned in clockwise
direction, the hotter is the water.
7.4 The Electric Water Heater might not be hot enough even at the ‘MAX’
position if the incoming water supply from the mains is too cold or the
pressure of water is too high. In this case, you may adjust the 3 in 1 Stop
Valve to reduce the water inflow in order to get the desired showering
temperature. (Recommended flow rate of below 6litre/min)
7.5 Check the Built-in ELCB as follows:
- Press the “TEST” Button, the Built-in ELCB should trip and cut off the power supply, ELCB and Power Indicators should light off.
- Press the “RESET” Button, the 3 LED
Indicator light shall run ON/OFF 3 times in sequences to indicate self- checking as in 7.2 above and the Electric Water Heater should resume normal function, the Green LED Indicator should light on. If procedures stated above prevailed, the ELCB is functioning in normal condition.
7.6 The height and direction of the Shower The holder are adjustable by releasing the shower holder knob clockwise and anticlockwise.
7.7 Move the Handshower to the desired angle. A ratchet mechanism in the Shower Holder will hold the Handshower in selected position.
7.8 It is unnecessary to turn the Temperature Control Knob to the “OFF” position when the Instant Hot Shower is not in use.
7.9 Switch OFF the power supply after shower.
7.10 For Pump model: The pump will auto ON when power ON and 3 in 1 stop valve open (and there is water supply)
7.11 Booster Pump Function: After the incoming power supply is ON, and water supply flow-through 3 in 1 stop valve while open position but the water flow rate is not sufficient to activate the flow sensor, Booster Pump Function can be useful to help to increase the incoming water flow rate. Press the pump button to activate the booster pump function. The booster pump function will be ON to increase the incoming water flow rate. While the Booster Pump Function is working and the incoming water flow rate can be maintained above flow sensor activation level, the Electric Water Heater will be resumed working continuously as normally. If the incoming flow rate can not be maintained above flow sensor activation level, the Booster Pump Function will be auto OFF and the Electric Water Heater will not be able to function normally due to the incoming flow rate is too low. (Advisable to avoid applying Booster Pump Function to increase the incoming water flow rate more than 3 times of each showering).
HANDSHOWER SPRAY
This Innovative adjustable Handshower has 5 different spray patterns (STANDARD, JUMBO, SOOTHE, MIX and MASSAGE. The patterns are described as follows:
Clean the Handshower Head holes by using the soft brush from time to time.
Recommended once a week)
Note: Take care not to damage the holes of the Handshower Head during
cleaning.
MAINTENANCE
Read the section ‘ SAFETY INFORMATION ’ first.
9.1 TEST THE ‘ELCB’ REGULARLY
(This procedure is highly recommended test at least once a month)
Turn on the power supply and water supply , both Red (HEATER) and Green (ELCB)
Indicators will light up if the Temperature Control Knob is in ‘ON ’ position.
Press the ELCB Test Button, both HEATER and ELCB Indicators should go off.
Press the Reset Button to resume the power supply.
9.2 CLEAN THE FILTER REGULARLY
Clean the Mesh Filter regularly to prevent blockage (Fig. 8) . Remove the
Built-in Filter by turning its cap anticlockwise. Whenever need flush the
internal stainer with water to remove any trapped sediments. Whenever fixing
back the Built-In Filter, beware of the alignment of Internal Strainer. Use
the protruded guideline within Stop Valve to position the Internal Strainer.
WARNING!
9.3 If the Red (POWER) Indicator does not go off when you press the ELCB Test
Button, switch OFF the mains supply and contact Electrolux Consumer Care
Centre for repair service. Special skill is required for repairing. NEVER try
to repair the unit by yourself.
9.4 CLEANING PRECAUTION ! Do not use thinner, alcohol, petrol or any other
organic solutions to clean the set. Use only damped cloth with mild detergent.
10. WIRING DIAGRAM
WIRING DIAGRAM (CON’D)
Thermostat Manual Reset (90° C Thermostat)
For Models rated 4.8kW and below, thermostat is manually resetable.
For models rated 6.0kW and above, thermostat needed to be replaced once
permanently tripped.
ELECTRICAL SPECIFICATION
TYPE | ELECTRONIC POWER CONTROL |
---|
ELECTRICAL LOADING
| 2.4kW TO 6.0kW 220V-240V a.c. 50/60Hz
3.6kW 240V a.c. 50/60Hz (Malaysia Model Only)
Min. WATER FLOW RATE| 2 Litre / min (2.2 ℓ/Min for 4.8kW & 2.5 ℓ/min for 6.0kW
model only)
Min. INLET WATER PRESSURE| 0.1 Bar (10 kPa ; 1.45 psi)
Max. INLET WATER PRESSURE| 6.0 Bar (0.6 MPa ; 87.02 psi)
WATER CONNECTION| 1/2” BSP SINGLE POINT SYSTEM
DIMENSIONS| 220 (W) X 401 (H) X 90 (T) mm
NET WEIGHT| 2.5 kg AC Pump Model
2.0 kg DC Pump Model
1.5 kg No Pump Model / 1.7 kg No Pump Model (6kW)
Note: The specification, actual product’s cosmetic design and accessories
parts showed are
correct at the time of printing and may be subjected to change without prior
notice.
WE’RE THINKING OF YOU
Thank you for purchasing an Electrolux appliance. You’ve chosen a product that
brings with it decades of professional experience and innovation. In genious
and stylish, it has been designed with you in mind. So whenever you use it,
you can be safe in knowledge that you’ll get great results every time. Welcome
to Electrolux.
Visit our website to:
Get usage advice, brochures, trouble shooter, service information:
www.electrolux.com
Register your product for better service:
www.registerelectrolux.com
Buy Accessories, Consumables and Original spare parts for your appliance:
www.electrolux.com/shop
CONSUMER CARE AND SERVICE
We recommend the use of original spare parts.
When contacting Service, ensure that you have the following data available.
The information can be found on the rating plate. Model, PNC, Serial Number.
(Right side of unit).
Warning/ Caution-Safety information.
General information and tips.
Environmental information.
Subject to change without notice.