aNSONIC GAMMA NX 1 Programmable UHF Tranceiver 457-462 MHz Narrow Band Instructions

June 6, 2024
aNSONIC

aNSONIC GAMMA NX 1 Programmable UHF Tranceiver 457-462 MHz Narrow

OverView

This NX1 version is based on our known European versions of NX1. It operates as GFSK narrowband transceiver in either simple Modem operation or in packet mode. All functions and technical data remain as in the standard NX1, except the selectable frequency ranges: those are in the 460MHz band to meet North American regulations. That means that the modules fall into the FCC Part90.217 mobile land regulation licensed band. Operation in US-FCC and Canada-IC is permitted due to according certification. Import to US/Canada is allowed if customers product refers to ‘contains FCC ID: 2A28Q-NX1 / IC ID: 27776-NX1 part’. For all further and detailed module operations please use the standard NX1-MP data sheets.

Warnings/Recommendations

  • RF Exposure recommendations: The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously or operated in conjunction with any other antenna or transmitter within a device. End-users, installers and OEM integrators must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance
  • 15.21 Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Les changements ou modifications qui ne sont pas expressément approuvés par la partie responsable de la conformité peuvent annuler l’autorité de l’utilisateur à utiliser l’équipement.
  • 15.19(a)(1) This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Cet appareil est conforme aux règles ICES-003. Son utilisation est soumise à la condition que cet appareil ne provoque pas d’interférences nuisibles.

Modul Characteristics

Absolute Maximum Ratings

Parameter Min Typ Max Unit Condition
Supply Voltage 2.5   15 V
Input/ RF Level     10 dBm

General Parameters – US/Canada version

Applicable Standard/ compliance FCC part 90.217 / ISED RSS-119
Transceiver type PLL based fully integrated digital narrow

band transceiver

Frequency Band| 457.7 – 462.5 MHz; narrow band with

typical OBW <=10kHz

Number of channels| 16 selectable, see table below
Preprogrammed frequencies| See table below
Channel Step| typ. <= 25 kHz
Frequency resolution| 16 Hz
Modulation| 2-GFSK
Data rate (transparent mode /

Modem operation)

| Max 4000 bps, typ. 2kHz
Oscillation method| Crystal (TCXO) based PLL oscillator,

temperature compensated

Frequency stability: Aging first year| Max. 1ppm (~ 0,4kHz)
Frequency stability: Temperature

drift (-30 to + 80 C)

| Max. 2ppm (~ 0,9 kHz)
Startup time| < 10ms
RX/TX turnaround time| RX->TX:<1ms

TX->RX:<4ms

Data logic| Positive
Operating temp. range| -30 to +80 C
Supply Voltage| 3.0-15V
Dimensions| 36x26x8mm
 |
RECEIVER SPECS

Sensitivity| -117 dBm (2 kbps)
Blocking & Selectivity| 60 dB (25 kHz adjacent channel)
Phase noise| -115 dBc/Hz at 10 kHz offset
Data logic| Positive
Receiver polarity| Data out: Low frequency=Lo, High

frequency=Hi

RSSI variation range| -117 to -60 dBm
Current consumption| 27mA (9mA in special sniff mode)
TRANSMITTER SPECS
Power Output| 15dBm
Adjacent channel power| -61 dBc (2-GFSK at 2.4 kbps)
SPECIAL
General purpose I/O (GPIO):| on demand, up to 14

Device Startup Time

RSSI_Output (NX 1)

aNSONIC GAMMA NX 1 Programmable UHF Tranceiver 457-462 MHz Narrow
Fig3

Module bottom

aNSONIC GAMMA NX 1 Programmable UHF Tranceiver 457-462 MHz Narrow
Fig4

Programming via FRQ0-3 Pins

aNSONIC GAMMA NX 1 Programmable UHF Tranceiver 457-462 MHz Narrow
Fig5

Further Specifications

Parameter Min Typ Max Unit
       
Vin 2.5   12 V
Logic Input High Voltage 2   12 V
Logic Input Low Voltage     0.2/0.3* V
Logic Output High Voltage 2/3*     V
Logic Output Low Voltage     0.3 V

*Low Power/ High Power

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

aNSONIC User Manuals

Related Manuals