A. The installation flow chart is as follows:

Installation flow chart

B. The detailed installation process is as follows:

1. Attach shielding materia:

1.1. Use amorphous laminating machine, adjust the parameters before use;

1.2. Joint before must ensure the neatness of PCB, shielding materials, PCB, shielding materials and platform must be perfectly, can’t offset, shielding material can’t fold, not beyond the PCB edge, the intracrystalline shrinkage is less than 1.0 mm. Figure 1 and 2:

2. Split control card:

The control card is placed in the fixed slot, press the work button, and separate the control card. As shown in figure 3:

3. Installation control card:

Insert the two gold finger ends of FPC at the connector opening at the same time and insert the connector flatly.

Push the line to the bottom of the connector and press down the connector cover,

4. The performance test:

Test the electromagnetic panel to be tested by connecting the test equipment to the test equipment:

Observe whether there are bending, line breaking, cursor not in position, shake and other fault defects.

5. Clean the PCB:

Wipe the front and back of the antenna plate with a dust-free cloth dipped in alcohol.

6. Double-sided tape on the back of control card:

On the back of the control card, paste 3020T0.1mm double-sided adhesive,

7. Double-sided adhesive is affixed to the back of antenna plate: The antenna plate is folded down and pasted with black 3M double-sided adhesive,

8. Fixed control panel:

The FPC of the antenna plate is folded by using the folding tooling, and the control card is fixed on the back of the antenna plate,

9. Paste insulating film:

Attach the yellow insulating film to the front of the control card to avoid the connector on the control

10. Appearance test:

Inspect the appearance of the finished product, screen and label the defective products with defects such as the edge of PCB, the edge of the board and the dirty surface of the board.

C. inspection and packing

Send the good products to the inspection, after the inspection qualified, packaging into the warehouse.

Federal Communication Commission Interference Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

IMPORTANT NOTE:

This NFC devices must be installed and used in strict accordance with the manufacturer’s instructions as described in the user documentation that comes with the product. Any other installation or use will violate FCC Part 15 regulations. Modifications not expressly approved by Getac could void your authority to operate the equipment.

This module apply limit module approval, and just only install in end product (Brand:Getac / Model: K120G2).

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Radiation Exposure Statement:

The product comply with the FCC portable RF exposure limit set forth for an uncontrolled environment and are safe for intended operation as described in this manual. The further RF exposure reduction can be achieved if the product can be kept as far as possible from the user body or set the device to lower output power if such function is available.

End Product Labeling:

The final end product must be labeled in a visible area with the following: “Contains FCC ID: QYLGET125K”. The grantee’s FCC ID can be used only when all FCC compliance requirements are met.

Manual Information To the End User

The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module.

The end user manual shall include all required regulatory information/warning as show in this manual.

Industry Canada statement:

This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Radiation Exposure Statement:

The product comply with the Canada portable RF exposure limit set forth for an uncontrolled environment and are safe for intended operation as described in this manual. The further RF exposure reduction can be achieved if the product can be kept as far as possible from the user body or set the device to lower output power if such function is available.

IMPORTANT NOTE:

In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the Canada authorization is no longer considered valid and the IC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re- evaluating the end product (including the transmitter) and obtaining a separate Canada authorization.

End Product Labeling

The product can be kept as far as possible from the user body or set the device to lower output power if such function is available. The final end product must be labeled in a visible area with the following: “Contains IC: 10301A-GET125K”.

Manual Information To the End User

The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module.

The end user manual shall include all required regulatory information/warning as show in this manual.

FCC ID : QYLGET125K
IC : 10301A-GET125K

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Getac User Manuals

Related Manuals