Comba MIRCU-S24 Multi internal Remote Control Unit User Manual
- June 6, 2024
- Comba
Table of Contents
Comba MIRCU-S24 Multi internal Remote Control Unit
Foreword
This user manual describes the basic use of electrical tilt antenna connected
to the Multi Internal Remote Control unit (MIRCU). Due to different equipment
and software upgrade, some description in this manual may differ from the
actual use. Information contained in this document is subjected to change
without prior notice.
Safety Precaution
- Install safety sign onsite to let public know that area is dangerous for public; operating personnel must use Protection Equipment during work.
- Pay attention for any high Voltage cable around during installation, be careful and avoid electrical shock.
- Make sure Antenna installed in protection angle of the tower Lightning rod.
- Grounding Cable must be installed, make sure the grounding resistance lesser than 5Ω.
Overview
Main Purpose & Scope of Application
MIRCU is a controller for electrical tilt enabled antenna to perform remote
electrical tilting. It meets AISG2.0 & AISG3.0 standards, suitable to be use
with all Ericsson, Nokia, Huawei, and ZTE AISG2.0 & AISG3.0 Base Station.
Model Description
Normal Working Conditions and Environment
- Ambient temperature: -40 ℃ to +60 ℃
- Power supply: DC +10 V to +30 V
Dimension & Weight
MIRCU outline drawing is shown in Figure 1 below:
Size and weight are shown in Table 1 below:
Model| Dimensions (L × W × H)/mm| Weight/kg (Approximate)|
Package Size (L × W × H)/mm
---|---|---|---
MIRCU-S24| 141x125x41| 0.5| 160×178×87
Table 1 IRCU Dimensions and Weight
MIRCU Specification
- For MIRCU specification please refer to MIRCU Datasheet.
- MIRCU tilting angle with adjustment accuracy of ± 0.1 °.
RET System and Working Principle
RET System
Multi Remote Electrical Tilt (RET) system consists of 2 major part, electrical
tilt enabled antenna and controller.
Working Principle
MIRCU obtains control information or number of motor rotation pulse throughout
calibration. By adjusting the motor rotation of MIRCU, it is able to gain
movement control of the phase shifter in an antenna, and thus able to control
antenna electrical tilt angle. While maintaining real time communication
between
MIRCU and PCU (Portable Control Unit), PCU send control command to MIRCU;
MIRCU will return the control result to PCU, and PCU act as Human-Machines
interface.
2 Primaries Working Principle
The MIRCU-S24 module has 2 pairs of AISG ports and supports AISG3.0 protocol,
and can be controlled by 2 primaries (Base Stations) which meet AISG2.0 or
AISG3.0 protocol at the same time. The AISG ports of the module share the same
configuration information and have the same serial number.
There are 2 motors inside MIRCU-S24, which can drive 8-frequency antenna currently. In near future, with the increase complexity of antenna demand, the firmware will be updated to supported up to 20-frequency antenna, expected to be done by Q2 2021.
The 2 pairs of AISG ports have no difference on function but authority. Any
band can be assigned by AISG port no matter AISG 1 or 2, provided the band is
not yet configured by another AISG port.
The device serial numbers that can be read by ASIG2.0 base station by scanning
the MIRCU-S24 module are as follows: (default access permission)
When the device access permission for
the port is shown as “No Access”, the AISG2.0 base station will not be able to
scan the device. The access permission of the port is set by MALD
configuration command as defined in AISG3.0 protocol.
For example, the module has 8 devices and the device access permissions are
set as below:
RET | PROT1 | PORT2 |
---|---|---|
CB 01CB20C1234567-Y1 | Read & Write | No Access |
CB 02CB20C1234567-Y2 | Read & Write | No Access |
CB 03CB20C1234567-Y3 | Read & Write | No Access |
CB 04CB20C1234567-Y4 | Read & Write | No Access |
CB 05CB20C1234567-R1 | No Access | Read & Write |
CB 06CB20C1234567-R2 | No Access | Read & Write |
CB 07CB20C1234567-R3 | No Access | Read & Write |
CB 08CB20C1234567-R4 | No Access | Read & Write |
When the AISG2.0 base station is connected, port 1 can scan to
CB01CB20C1234567-Y1, CB02CB20C1234567-Y2, CB03CB20C1234567-Y3,
CB04CB20C1234567-Y4, 4 devices. Port 2 can scan to CB05CB20C1234567-R1,
CB06CB20C1234567-R2, CB07CB20C1234567-R3, CB08CB20C1234567-R4, 4 devices.
The device serial numbers that can be read by the AISG3.0 base station by
scanning the MIRCU-S24 module are as below:
Operation in AISG2.0 Mode
A summary of operation conflict for 2 primaries (1st & 2nd Primary) operating MIRCU-S24 is shown in table below:
**Note: All “√” and “X” shown are mainly in connection to the 2nd primary, which implies whether or not the corresponding action (listed horizontally in table) can be performed on the 2nd primary when the 1st primary is executing a certain command or action (listed vertically in table). The order of priority of the “primary” is not fix and it is depending on which primary actually starts an action 1st.
2 nd Primary
1 st Primary
|
Scan
|
Calibrat ion
|
Set Tilt
|
L2
Restora tion
|
L7
Restora tion
|
Update Config file
|
Update Firmwar e
|
Informa tion
|
Set Device Data
|
Self -t est
---|---|---|---|---|---|---|---|---|---|---
Scan
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
Calibration
|
√
|
X
|
X
|
√
|
√
|
X
|
X
|
√
|
√
|
√
Set Tilt
|
√
|
X
|
X
|
√
|
√
|
X
|
X
|
√
|
√
|
√
L2 Restoration
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
L7 Restoration
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
Update Config file|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
Update Firmware|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
Information
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
Set Device Data|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
Self-test
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
X: Note 1) MIRCU cannot operate the commands from 2 respective primaries
simultaneously.
It conflicts each other and doesn’t comply with AISG standard.
Note 2) 1 primary can operate the command successfully, but the command
sent by another primary failed to achieve.
√:Note 1) MIRCU-S24 can operate the commands from 2 respective primaries
simultaneously, and comply with AISG standard.
Note 2) Although ‘Update Config File’ and ‘Update Firmware’ can run on
2nd primary while 1st primary is performing an action, the link on 1st primary
will break then and all actions will stop and fail to operate.
a) Scan
MIRCU-S24 supports 2 primaries to scan MIRCU simultaneously. When 1st primary
is scanning, the 2nd primary is able to scan, calibrate, set tilt, restore
L2/L7, update configuration file, update firmware, get MIRCU information, set
device data and self-test.
When 1st primary is scanning, if 2nd primary send command to MIRCU, the impact
on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Support| No Impact
Set Tilt| Support| No Impact
L2 /L7 Restoration| Support| No Impact
Update Configuration File| Support| Broken Link
Update Firmware| Support| Broken Link
Get Information| Support| No Impact
Set Device Data| Support| No Impact
Self-test| Support| No Impact
b) Calibration
MIRCU-S24 does NOT support 2 primaries to perform calibration simultaneously.
When 1st primary is calibrating, the 2nd primary is able to scan MIRCU,
restore L2/L7, get MIRCU information, set device data and self-testing but NOT
able to calibrate, set tilt, update configuration file and update firmware.
When 1st primary is calibrating, if 2nd primary send command to MIRCU, the
impact on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Reply “Busy”| No Impact
Set Tilt| Reply “Busy”| No Impact
L2 /L7 Restoration| Support| No Impact
Update Configuration File| Reply “Busy”| No Impact
Update Firmware| Reply “Busy”| No Impact
Get Information| Support| No Impact
Set Device Data| Support| No Impact
Self-test| Support| No Impact
c) Set Tilt
MIRCU-S24 does NOT support 2 primaries to set tilt simultaneously. When 1st
primary is setting tilt, the 2nd primary is able to scan MIRCU, restore L2/L7,
get MIRCU information, set device data and self-testing but NOT able to
calibrate, set tilt, update configuration file and update firmware.
When 1st primary is setting tilt, if 2nd primary send command to MIRCU, the
impact on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Reply “Busy”| No Impact
Set Tilt| Reply “Busy”| No Impact
L2 /L7 Restoration| Support| No Impact
Update Configuration File| Reply “Busy”| No Impact
Update Firmware| Reply “Busy”| No Impact
Get Information| Support| No Impact
Set Device Data| Support| No Impact
Self-test| Support| No Impact
d) L2 /L7 Restoration
MIRCU-S24 supports 2 primaries to restore L2 or L7 simultaneously. It will not
cause hardware reset of the entire module. When 1st primary is restoring
L2/L7, the 2nd primary is able to scan, calibrate, set tilt, restore L2/L7,
update configuration file, update firmware, get MIRCU information, set device
data and self-test.
e) Upload Configuration File
MIRCU-S24 does NOT support 2 primaries to update configuration file
simultaneously. When 1st primary is updating configuration file, the 2nd
primary can NOT perform any operation. It will reset and the link will be
disconnected.
f) Update Firmware
MIRCU-S24 does NOT support 2 primaries to update firmware simultaneously. When
1st primary is updating firmware, the 2nd primary can NOT perform any
operation. It will reset and the link will be disconnected.
g) Getting MIRCU Information
MIRCU-S24 supports 2 primaries to get RET information simultaneously. When 1st
primary is getting MIRCU information, the 2nd primary is able to scan,
calibrate, set tilt, restore L2/L7, update configuration file, update
firmware, get MIRCU information, set device data and self-test.
When 1st primary is setting tilt, if 2nd primary send command to MIRCU, the
impact on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Support| No Impact
Set Tilt| Support| No Impact
L2 /L7 Restoration| Support| No Impact
Update Configuration File| Support| Broken Link
Update Firmware| Support| Broken Link
Get Information| Support| No Impact
Set Device Data| Support| No Impact
Self-test| Support| No Impact
h) Set Device Data
MIRCU-S24 supports 2 primaries to set device data simultaneously. When 1st primary is setting device data, the 2nd primary is able to scan, calibrate, set tilt, restore L2/L7, update configuration file, update firmware, get MIRCU information, set device data and self-test.
**Note: The data that can be changed include Installation date,
Installer’s ID, Base station ID, Sector ID, Antenna bearing (degrees),
Installed mechanical tilt (degrees) and Antenna serial number. Antenna model
number, Antenna operating band(s), Beamwidth, Gain (dB), Maximum tilt
(degrees) and Minimum tilt (degrees) can NOT be changed, MIRCU-S24 will reply
“Ready Only”.
When 1st primary is setting device data, if 2nd primary send command to MIRCU,
the impact on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Support| No Impact
Set Tilt| Support| No Impact
L2 /L7 Restoration| Support| No Impact
Update Configuration File| Support| Broken Link
Update Firmware| Support| Broken Link
Get Information| Support| No Impact
Set Device Data| Support| No Impact
Self-test| Support| No Impact
i) Self-test
MIRCU-S24 supports 2 primaries to perform self-testing simultaneously. When
1st primary is performing self-testing, the 2nd primary is able to scan,
calibrate, set tilt, restore L2/L7, update configuration file, update
firmware, get MIRCU information, set device data and self-test.
When 1st primary is performing self-testing, if 2nd primary send command to
MIRCU, the impact on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Support| No Impact
Set Tilt| Support| No Impact
L2 /L7 Restoration| Support| No Impact
Update Configuration File| Support| Broken Link
Update Firmware| Support| Broken Link
Get Information| Support| No Impact
Set Device Data| Support| No Impact
Self-test| Support| No Impact
Operation in AISG3.0 Mode
A summary of operation conflict for 2 primaries (1st & 2nd Primary) operating MIRCU-S24 is shown in table below:
**Note: All “√” and “X” shown are mainly in connection to the 2nd primary, which implies whether or not the corresponding action (listed horizontally in table) can be performed on the 2nd primary when the 1st primary is executing a certain command or action (listed vertically in table). The order of priority of the “primary” is not fix and it is depending on which primary actually starts an action 1st.
2 nd Primary
1 st Primary
|
Scan
|
Calibrati on
|
Set Tilt
|
Reset Port
|
Reset ALD
|
Upload
|
Downloa d
|
MALD
Configur e
|
Ping
---|---|---|---|---|---|---|---|---|---
Scan
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
Calibration
|
√
|
X
|
X
|
√
|
√
|
X
|
X
|
X
|
X
Set Tilt
|
√
|
X
|
X
|
√
|
√
|
X
|
X
|
X
|
X
ResetPort
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
|
√
ResetALD
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
Upload
|
√
|
X
|
X
|
√
|
√
|
X
|
X
|
X
|
X
Download
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
MALD Configure
|
√
|
X
|
X
|
√
|
√
|
X
|
X
|
X
|
X
Ping
|
√
|
X
|
X
|
√
|
√
|
X
|
X
|
X
|
X
X:Note 1) MIRCU cannot operate the commands from 2 respective primaries
simultaneously.
It conflicts each other and doesn’t comply with AISG standard.
Note 2) 1 primary can operate the command successfully, but the command sent by another primary failed to achieve.
√:Note 1) MIRCU-S24 can operate the commands from 2 respective primaries
simultaneously, and comply with AISG standard.
Note 2) ‘When “RESETALD” is run on 2nd primary when 1st primary is
performing an action, all the action on the 1st primary will be suspended.
a) Scan
MIRCU-S24 supports 2 primaries to scan MIRCU simultaneously. When 1st primary
is scanning, operation on 2nd primary is not affected and it is able to scan,
calibrate, set tilt, reset port, reset ALD, upload/download file, configure
MALD and ping.
When 1st primary is scanning, if 2nd primary send command to MIRCU, the impact
on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Support| No Impact
Set Tilt| Support| No Impact
ResetPort| Support| No Impact
ResetALD| Support| Broken Link
Upload File| Support| No Impact
Download File| Support| Broken Link
MALD Configure| Support| No Impact
PING| Support| No Impact
b) Calibrate
MIRCU-S24 does NOT support 2 primaries to perform calibration simultaneously.
When 1st primary is calibrating, the 2nd primary is able to scan, reset port,
reset ALD but NOT able to calibrate, set tilt, upload/download file, configure
MALD and ping.
When 1st primary is calibrating, if 2nd primary send command to MIRCU, the
impact on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Return “UseByAnotherPort”| No Impact
Set Tilt| Return “UseByAnotherPort”| No Impact
ResetPort| Support| No Impact
ResetALD| Support| Broken Link
Upload File| Return “UseByAnotherPort”| No Impact
Download File| Return “UseByAnotherPort”| No Impact
MALD Configure| Return “UseByAnotherPort”| No Impact
PING| Return “UseByAnotherPort”| No Impact
c) SetTilt
MIRCU-S24 does NOT support 2 primaries to set tilt simultaneously. When 1st
primary is setting tilt, the 2nd primary is able to scan, reset port, reset
ALD but NOT able to calibrate, set tilt, upload/download file, configure MALD
and ping.
When 1st primary is setting tilt, if 2nd primary send command to MIRCU, the
impact on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Return “UseByAnotherPort”| No Impact
Set Tilt| Return “UseByAnotherPort”| No Impact
ResetPort| Support| No Impact
ResetALD| Support| Broken Link
Upload File| Return “UseByAnotherPort”| No Impact
Download File| Return “UseByAnotherPort”| No Impact
MALD Configure| Return “UseByAnotherPort”| No Impact
PING| Return “UseByAnotherPort”| No Impact
d) Reset
AISG3.0 has 2 kind of reset operations: ResetPort and ResetALD. ResetPort only
resets the pair of port connecting to the 1st OR 2nd primary and does NOT
affect the operation of another primary. ResetALD resets the whole module and
it will restart, both primaries will hence be disconnected.
e) Upload (Fetch File from Module)
The upload command starts with ‘UploadStart’ and ends with ‘UploadEnd’. The
file is carried and uploaded by using ‘UploadFile’ command. The supported file
types are FirmwareFile and ConfigureFile. The module does not support multi-
ports file upload operation simultaneously, which mean when 1st primary is
performing upload, the 2nd primary will be in ‘Restricted Connection State’.
When 1st primary is uploading file, if 2nd primary send command to MIRCU, the
impact on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Return “IncorrectState”| No Impact
Set Tilt| Return “IncorrectState”| No Impact
ResetPort| Support| No Impact
ResetALD| Support| Broken Link
Upload File| Return “IncorrectState”| No Impact
Download File| Return “IncorrectState”| No Impact
MALD Configure| Return “IncorrectState”| No Impact
PING| Return “IncorrectState”| No Impact
f) Download (Download file to Module)
The file download command starts with ‘DownloadStart’ and ends with ‘DownloadEnd’. The file is carried and downloaded by using ‘DownloadFile’ command. The supported file types are FirmwareFile and ConfigureFile. The module does not support multi-ports file download operation simultaneously, which mean when 1st primary is performing download, the 2nd primary ports will be close and no operation can be performed.
g) MALD Configure
When MALD configuration is performed on the module, the access authority of
the module port to each of the subunit of the antenna can be configured. When
MALD configuration operation is performed on the 1st primary, the 2nd primary
will be in
‘Restricted Connection State’.
When 1st primary is configuring MALD, if 2nd primary send command to MIRCU,
the impact on the 1st primary is shown in table below:
2 nd Primary Action| If MIRCU Support| Impact on 1
st Primary
---|---|---
Scan| Support| No Impact
Calibration| Return “IncorrectState”| No Impact
Set Tilt| Return “IncorrectState”| No Impact
ResetPort| Support| No Impact
ResetALD| Support| Broken Link
Upload File| Return “IncorrectState”| No Impact
Download File| Return “IncorrectState”| No Impact
MALD Configure| Return “IncorrectState”| No Impact
PING| Return “IncorrectState”| No Impact
h) Ping
When 1st primary is performing PING operation, the 2nd primary will be in ‘Restricted Connection State’. Please refer to AISG3.0 protocol for details PING operation. When 1st primary is performing ping, if 2nd primary send command to MIRCU, the impact on the 1st primary is shown in table below:
2 nd Primary Action
|
If MIRCU Support
| Impact on 1 st Primary
---|---|---
Scan| Support| No Impact
Calibration| Return “IncorrectState”| No Impact
Set Tilt| Return “IncorrectState”| No Impact
ResetPort| Support| No Impact
ResetALD| Support| Broken Link
Upload File| Return “IncorrectState”| No Impact
Download File| Return “IncorrectState”| No Impact
MALD Configure| Return “IncorrectState”| No Impact
PING| Return “IncorrectState”| No Impact
MIRCU Installation and Connection
Installation Requirement
Control Cable Requirement
-
Control Cable connector:
Meet the requirements of IEC60130-9 8-pin connector. End of cable are composition of Male and Female Connectors, connector and cable core meet the AISG interface standard requirements. -
Cable:
Composition of 5 core with metal and plastic protective layer shielding cable, core diameter requirements: 3 × 0.75mm + 2 × 0.32mm. -
Protection class:
IP65
Power Supply
MIRCU Input Power: DC +10 V ~ +30 V
Installation Tools
32mm open-end Torque wrench x 1.
MIRCU-S24 Installation
MIRCU-S24 Installation Steps and Methods
a) As shown in Figure 2, “AISG OUT” logo on Antenna cover need to be aligned with MIRCU “IN” and “OUT”, then insert MIRCU into antenna mounting slot.
b) As shown in Figure 3, tighten screws on MIRCU using a slotted type screwdriver. c) As shown in Figure 4, connect the control cable to the AISG Connector locate at the lower part of the MIRCU and tighten the connector.
d) If there is more than one MIRCU need to be connect, daisy-chained cascade method can be used as show in Figure 5. Figure 5 Multiple MIRCU Daisy-Chain Cascade Schematic Diagram
**Note: The control cables and MIRCU connectors at both ends were Male and Female connector. MIRCU male connector used to receive Input Signal and connect with female connector of control cables; MIRCU female connector used to transmit output signal and cascade in series to another MIRCU using male cable connector. Control cables from PCU only can be connect to the male connector of MIRCU.
e) Water proof: Firstly, wrap 3 layers of waterproof tape, then wrap 3 layers of insulating tape, fastened with cable ties at both ends.
Connection between MIRCU, PCU and Antenna System
Connection between MIRCU, PCU and antenna system connections are shown in
Figure 6. There are 3 connections, namely:
Figure 6(a): MIRCU directly connected with the PCU via the control cable;
Figure 6(b): MIRCU connected with antenna system terminal SBT (Smart
Bias-T), PCU and the base station apparatus connected to the end of SBT, the
control signal transmitted thru the RF feeder.
Figure 6(c): MIRCU connected with AISG interface enable TMA, PCU and the
base station apparatus connected to the end of SBT, the control signal
transmitted thru the RF feeder. Mapping of MIRCU to
Phase Shifter
Comba existing MIRCU can satisfy 1 to 8 RET phase shifter control, and will be
upgraded to support up to 20 phase shifter control in near future through
firmware upgrade, expected to be done by Q2 2021. All control and driver chip
are integrated into a single MIRCU module. The relative specifications are as
shown in Table 2.
Parameter
Product
| No. of Motor Driving Control Unit|
Suitable RET Antenna
|
Installation Manner
---|---|---|---
MIRCU-S24
|
2
| 1 to 8 freq band build-in RCU RET Antenna. Upgradable to 20 freq band in future.|
Plug and play
Table 2 MIRCU in relation to Antenna Suitability
Comba MIRCU product, as shown in Figure 7 and Figure 8, employ the usage of socket, so as to realize the plug-and-play function whereby the MIRCU can be easily installed or uninstalled. It greatly enhances the reliability of the product in term of connection and utilization. Also, the maintenance is greatly simplified. Each Driver Unit/Motor comes with their own serial number. For Figure 9 below, 8 set of serial numbers will be displayed on PCU when connected. MIRCU Control Cable, Lightning Protection and Grounding cables
Control cable, Lightning Protection and Grounding requirements
MIRCU control cable can connect through SBT or TMA (as shown in Figure 6 (b), (c)), normally control cable will be short and not more than 2m, lighting protection and grounding will be implemented along the RF feeder and hence it is not necessary for control cable to carry out lightning Protection and grounding again.
However, if MIRCU and control cable are connected as Figure 6 (a), whereby control cable connect to RCU directly, then it is necessary for the cable control to proceed with Lightning Protection and Ground requirement. Details as follows:
- a) Control cables that connect to base station antenna should be within the scope of protection of the air terminals. Air terminals shall establish special lightning current deflectors, materials suitable are 4mm x 40 mm galvanized flat steel.
- b) Control cables metal sheath should be clamp to grounding kit within 1m of antenna, 1m within the cable tray at the bottom of the tower, and 1m before entering base station shelter. Make sure grounding cable is installed property, feeder window of the shelter room should be close to the ground and properly connect to the grounding bar that leads to the ground. (See Figure 10)
c) Control cables metal sheath attach to grounding kit as shown in Figure 11.
Grounding Kit Installation Procedure
- a) Prepare ground kit, as shown in Figure 12 1a.
- b) Clean the plastic sheath of the control cables, cutting plastic sheath with a suitable stripper tool, expose metal braid sheath of control cable, with length about 22mm, as shown in the Figure 12 1b.
- c) Remove the protection sheet on the ground kit, clamping the grounding kit around the control cable, and align with striped line as shown in Figure 13
- d) Tighten the screws of the grounding kit, as show in Figure 14.
- e) Connect and tighten grounding cable on the grounding bar which locate at bottom of the tower.
**Note: The control cables should be in upright position while clamping with grounding kit.
Transportation and Storage
Transportation
Equipment can be carriage by car, train, ship, airplane or other
transportation vehicles. Do prevent rain, avoid excessive vibration and impact
during the transportation. Handle with care while loading and unloading,
strictly avoid dropping from high and other rough handling.
Storage
Packaged equipment should be placed in dry and ventilated area, ambient air
without acidic, alkaline and other corrosive gas. Box stacking shall comply
with specification on the box. Storage period should not exceed 2 years, good
stored for more than 2 years will need to pass re-inspection test before use.
Caution and Note
Caution
Caution: The user is cautioned that changes or modifications not
expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Read User Manual Online (PDF format)