Wis networks WCAP-PLUS User Guide
- June 13, 2024
- WIS networks
Table of Contents
Wis networks WCAP-PLUS
Product Information
The product is an Outdoor LTE CPE (Customer Premises Equipment) designed for wireless internet connectivity. It comes in two models, WIS-H19-LTE and WIS- H19G-LTE. The package includes a feedhorn, dish, feed receiver, ball joint mount, 24V PoE adapter, and a quick setup guide. The device has various interfacesincluding Ethernet (ETH), LTE, and power (PWR) LEDs. It also features an Ethernet port, a reset button, and a Micro SIM card slot.
Install the radio
Instructions before installing
- Locate a suitable place with wall-mount or ceiling-mount.
- Do not install in illegal places to avoid violating the local regulatory rules.
- You may need tools below.
Install on the wall
-
Mark the drilling position according to the diagram.
-
Use 6mm drill and drill the hole depth 35-40mm.
-
Drive 3 expansion screw into the hole with a hammer. ATTENTION
The hole depth should not be more than 40mm, otherwise the device could not be mounted solidly. -
Drive the self-tapping screw.
-
Put the device to the mounting bracket, rotate as shown direction to complete the installation.
ATTENTION
Plug the Ethernet cable first before the final installation.
Power up the radio
Connect one end of an Ethernet cable to the POE port of the provided PoE DC
Adapter and the other end of the Ethernet cable to the RJ45 port of the
device. Then, connect the LAN port of the PoE DC Adapter to a PC or switch
using another Ethernet cable. Finally, plug the PoE DC Adapter into a standard
electrical wall socket.
ATTENTION
If you use other PoE Adapter which is not provided by Wisnetworks, we can’t
provide warranty service if device damage caused.
Managed by Controller
- Check all wires are correctly connected.
- Put the cloud controller in the same network ( subnet ) with the access point.
- Connect one PC to the controller ETH0 port and login web 192.168.1.1
- When login page appears enter “admin” in the password fields.
- Go to the AP menu of the controller, and you will find the new access point waiting for manage. Simply press the manage button and add the aps to controller network then ap will be managed.
- For more configurations like cloud deployment and wireless settings please visit website www.wis.us
Safety Notices
- Read, follow, and keep these instructions.
- Heed all warnings.
- Only use attachments/accessories specified by the manufacturer.
Note: It is important to check with the local operator whether the
supported LTE Bands or frequencies are compatible with Wisnetwork LTE devices
as different regions may use different LTE Bands.
WARNING:
Do not use this product in location that can be submerged by water.
WARNING:
Avoid using this product during an electrical storm. There may be a remote
risk of electric shock from lightning.
Electrical Safety Information
- Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
- There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
- This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
- Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
- The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
- Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
- Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
- Protective bonding must be installed in accordance with local national wiring rules and regulations.
Package content
Interface
CE Marking
CE marking on this product represents the product is in compliance with all
directives that are applicable to it. Alert sign must be indicated if a
restriction on use applied to the product and it must follow the CE marking.
RoHS/WEEE Compliance Statement
European Directive 2002/96/EC requires that the equipment bearing this symbol
on the product and/or its packaging must not be disposed of with unsorted
municipal waste. The symbol indicates that this product should be disposed of
separately from regular household waste streams. It is your responsibility to
dispose of this and other electric and electronic equipment via designated
collection facilities appointed by the government or local authorities.
Correct disposal and recycling will help prevent potential negative
consequences to the environment and human health. For more detailed
information about the disposal of your old equipment, please contact your
local authorities, waste disposal service, or the shop where you purchased the
product.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Limited Warranty
Wisnetworks warrants that the product(s) furnished hereunder (the
“Product(s)”) shall be free from defects in material and workmanship for a
period of one(1) year from the date of shipment by Wisnetworks under normal
use and operation. Wisnetworks sole and exclusive obligation and liability
under the foregoing warranty shall be for Wisnetworks, at its discretion, to
repair or replace any Product that fails to conform to the above warranty
during the above warranty period. The expense of removal and reinstallation of
any Product is not included in this warranty. The warranty period of any
repaired or replaced Product shall not extend beyond its original term.
Warranty Condition
The above warranty does not apply if the Product:
- has been modified and/or altered, or an addition made thereto, except by Wisnetworks, or our authorized representatives, or as approved by Wisnetworks in writing;
- has been painted, rebranded or physically modified in any way;
- has been damaged due to errors or defects in cabling;
- has been subjected to misuse, abuse, negligence, abnormal physical, electromagnetic or electrical stress, including lightning strikes, or accident;
- has been damaged or impaired as a result of using third party firmware;
- has no original Wisnetworks MAC/SN label, or is missing any other original Wisnetworks label(s);
- human reasons without according to the guide or user manual.
In addition, the above warranty shall apply only if: the product has been
properly installed and used at all times in accordance, and in all material
respects, with the applicable Product documentation; all Ethernet cabling runs
use CAT5 (or above), and for outdoor installations, shielded Ethernet cabling
is used, and for indoor installations, indoor cabling requirements are
followed.
Online Support
For more guide and help, please go to www.wis.us
You can contact email
sales@wis.us