FIMER Flexa AX WallBox VP Solar Instructions

June 6, 2024
FIMER

FIMER Flexa AX WallBox VP Solar

INTRODUCTION

The FIMER FLEXA AC Wallbox is a charging device for electric vehicles for private applications and for public or company car parking facilities, which can be installed on a wall or on a dedicated FIMER FLEXA Stand.

FIMER FLEXA AC Wallbox is available in a Cord version, equipped with a T2 Cord, or in a Socket version, equipped with a T2 or a T3A socket. The device can be installed on the wall or on a dedicated FIMER FLEXA Stand and is available in different configurations, depending on the power (from 3.7kW to 22kW), the connection type (T2 Cord or T2 socket or T3A socket) and the type of connectivity (Stand Alone, Inverter Net or Future Net). Each FIMER FLEXA AC Wallbox can be configured in Master
(Future Net) or Slave (Stand Alone or Inverter Net) mode: this configuration makes multiple installations (in public and company car parking facilities) even more efficient, through a built-in Load Management system.

FIMER FLEXA AC Wallbox – Stand Alone

The Stand-Alone version comes with basic features that guarantee easy use at an affordable price.
Its functionalities are limited to interaction with the electric vehicle, activating its charging process and ensuring its safe operation:

  • Status signaling via local LEDs and local RS485 communication for configuration and monitoring
  • Available in Cord (T2) or Socket (T2 or T3A) versions
  • Communication interface with MID counter or TA meter
  • Bluetooth communication and RFiD reader for local access management

FIMER FLEXA AC Wallbox – Future Net

The Future Net version includes great connectivity features that enable remote monitoring and control of the device. It offers the following features in addition to those of the Stand Alone version:

  • 3G/4G connectivity, Wi-Fi, Ethernet
  • OCPP 1.6 Json communication protocol
  • Intelligent remote monitoring and control system: thanks to the use of a mobile application for the user and a centralized system for the operator, it allows remote monitoring of the device status, the creation of use and energy reports, access management and error analysis
  • Master/Slave Management

FIMER FLEXA AC Wallbox – Inverter Net

The features of the Inverter Net version are similar to those of the Stand Alone version; it only differs in that it can communicate with REACT 2 photovoltaic inverters with storage. This version offers the following advantages compared to the Stand Alone version:

  • Data sharing and storage through interaction with REACT 2 photovoltaic inverters with integrated storage
  • Load optimization and integration with storage systems
  • Shared management portal for data monitoring and management
All versions have the following main features:
  • Available in Cord (Type 2) or Socket (Type 2 or Type 3A) version
  • Charge in Mode 3
  • Master-Slave functionality
  • Locking of the socket during the charging phase (only for the Socket version)
  • Bluetooth connectivity and RFiD reader
  • 100% recycled plastic
  • Communication interface with external amperometric transformer or MID energy meter
  • Installation on a wall or a dedicated FIMER FLEXA Stand system
  • Easy assembly

Signals and control

  • Local LED signals for indications of charging status or any faults
  • Authentication and unlocking systems via RFiD cards, mobile application or through a centralised management system
  • OCPP 1.6 Json protocol

TECHNICAL DATA

Technical data|  |  |  |  |
---|---|---|---|---|---
Model FIMER FLEXA AC Wallbox|  |  | Stand Alone / Inverter Net / Future Net|
Maximum power|  | 3.7 kW| 7.4 kW| 11 kW| 22 kW
Standard|  |  | IEC61851-1|
Charging method|  |  | Mode 3|
Available outlets|  |  | 5m Cord (Type2) or Socket (Type 2 or Type 3A)|
Power system|  | 1P + N + PE| 1P + N + PE| 3P + N + PE| 3P + N + PE
Rated voltage|  | 230V AC ± 10%| 230V AC ± 10%| 230/400V AC ± 10%| 230/400V AC ± 10%
Frequency|  |  | 50-60 HZ|
Rated current|  | 16A| 32A| 16A| 32A
Rated impulse withstand voltage (Uimp)|  |  | 4kV|
Rated conditional short-circuit current of an assembly (icc)”|  |  | 10kA|
Rated diversity factor (RDF)|  |  |  | 1|
Degree of pollution|  |  |  | 2|
EMC classification|  |  | Class B emissions|
Protective measures against electric shock|  |  | Class I|
Connection to the mains|  |  | Permanently connected to the mains|
Grounding system type|  |  | TT or TN (both with PE)|
Indoor/outdoor installation|  |  | External|
Fixed or removable installation|  |  | Fixed|
Overvoltage category|  |  | III|
IP protection rating|  |  | IP 55|
IK protection rating|  |  | IK08|
Case material|  |  | 100% recycled plastic|
Dimensions|  |  | 275 mm x 480 mm x 140 mm|
Weight|  |  | 7 kg (Socket), 8.5 kg (Cord)|
Operating temperature|  |  | -25….+50°C|
Storage temperature|  |  | -25…+70°C|
Humidity|  |  | 0…95% (non-condensing)|
Altitude|  |  | Up to 2000 m|
Product intended for use by|  |  | Unskilled persons|
Positioning in area with|  |  | Unlimited access|
Magnetothermal protection|  |  | Not included|
Differential protection|  |  | Not included (6mA DC RCM only included)|
Energy meter|  |  | Compatible with external MID meters or TA meters|
Certification|  |  | CE, AUX. UL|
Model FIMER FLEXA AC Wallbox|  |  | Stand| Alone|  |  |  | Inverte| r Net|  |  |  | Future| Net|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Maximum power|  | 3.7 kW| 7.4 kW| 11 kW| 22 kW|  | 3.7 kW| 7.4 kW| 11 kW| 22 kW|  | 3.7 kW| 7.4 kW| 11 KW| 22 kW
Bluetooth|  | •| •| •| •|  | •| •| •| •|  | •| •| •| •
RFiD|  | •| •| •| •|  | •| •| •| •|  | •| •| •| •
OCPP|  | | | | |  | | | | | | OCPP

1.6 Json

| OCPP

1.6 Json

| OCPP

1.6 Json

| OCPP

1.6 Json

3G/4G connection|  | | | | |  | | | | |  | •| •| •| •
Ethernet connection|  | | | | |  | | | | |  | •| •| •| •
WiFi|  | | | | |  | | | | | | •| •| •| •
Status LED|  | •| •| •| •|  | •| •| •| •|  | •| •| •| •
Remote SW Updates|  | | | | |  | •| •| •| •|  | •| •| •| •
Available codes|  |  |  |  |  |  |  |  |  |  |  |  |  |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Code|  | EAN|  | Description|  | Version|  | Pmax|  | Rated current|  | Rated voltage|  | Connection
FLWSA0302SSN00|  | 8033049748451|  | FIMER FLEXA AC Wallbox SA 3.7kW T2S|  | Stand Alone|  | 3.7 kW|  | 16A|  | 230V AC|  | T2 Socket
FLWSA0302CSN00|  | 8033049748468|  | FIMER FLEXA AC Wallbox SA 3.7kW T2C|  | Stand Alone|  | 3.7 kW|  | 16A|  | 230V AC|  | T2 Cord
FLWSA0303SSN00|  | 8033049748475|  | FIMER FLEXA AC Wallbox SA 3.7kW T3AS|  | Stand Alone|  | 3.7 kW|  | 16A|  | 230V AC|  | T3A Socket
FLWIN0302SSN00|  | 8033049748482|  | FIMER FLEXA AC Wallbox IN 3.7kW T2S|  | Inverter Net|  | 3.7 kW|  | 16A|  | 230V AC|  | T2 Socket
FLWIN0302CSN00|  | 8033049748499|  | FIMER FLEXA AC Wallbox IN 3.7kW T2C|  | Inverter Net|  | 3.7 kW|  | 16A|  | 230V AC|  | T2 Cord
FLWIN0303SSN00|  | 8033049748505|  | FIMER FLEXA AC Wallbox IN 3.7kW T3AS|  | Inverter Net|  | 3.7 kW|  | 16A|  | 230V AC|  | T3A Socket
FLWFN0302SSN00|  | 8033049748512|  | FIMER FLEXA AC Wallbox FN 3.7kW T2S|  | Future Net|  | 3.7 kW|  | 16A|  | 230V AC|  | T2 Socket
FLWFN0302CSN00|  | 8033049748529|  | FIMER FLEXA AC Wallbox FN 3.7kW T2C|  | Future Net|  | 3.7 kW|  | 16A|  | 230V AC|  | T2 Cord
FLWFN0303SSN00|  | 8033049748536|  | FIMER FLEXA AC Wallbox FN 3.7kW T3AS|  | Future Net|  | 3.7 kW|  | 16A|  | 230V AC|  | T3A Socket
FLWSA0702SSN00|  | 8033049748543|  | FIMER FLEXA AC Wallbox SA 7.4kW T2S|  | Stand Alone|  | 7.4 KW|  | 32A|  | 230V AC|  | T2 Socket
FLWSA0702CSN00|  | 8033049748550|  | FIMER FLEXA AC Wallbox SA 7.4kW T2C|  | Stand Alone|  | 7.4 kW|  | 32A|  | 230V AC|  | T2 Cord
FLWIN0702SSN00|  | 8033049748567|  | FIMER FLEXA AC Wallbox IN 7.4kW T2S|  | Inverter Net|  | 7.4 kW|  | 32A|  | 230V AC|  | T2 Socket
FLWIN0702CSN00|  | 8033049748574|  | FIMER FLEXA AC Wallbox IN 7.4kW T2C|  | Inverter Net|  | 7.4 kW|  | 32A|  | 230V AC|  | T2 Cord
FLWFN0702SSN00|  | 8033049748581|  | FIMER FLEXA AC Wallbox FN 7.4kW T2S|  | Future Net|  | 7.4 kW|  | 32A|  | 230V AC|  | T2 Socket
FLWFN0702CSN00|  | 8033049748598|  | FIMER FLEXA AC Wallbox FN 7.4kW T2C|  | Future Net|  | 7.4 kW|  | 32A|  | 230V AC|  | T2 Cord
FLWSA1102SSN00|  | 8033049748604|  | FIMER FLEXA AC Wallbox SA 11kW T2S|  | Stand Alone|  | 11 kW|  | 16A|  | 230/400V AC|  | T2 Socket
FLWSA1102CSN00|  | 8033049748611|  | FIMER FLEXA AC Wallbox SA 11kW T2C|  | Stand Alone|  | 11 kW|  | 16A|  | 230/400V AC|  | T2 Cord
FLWIN1102SSN00|  | 8033049748628|  | FIMER FLEXA AC Wallbox IN 11kW T2S|  | Inverter Net|  | 11 kW|  | 16A|  | 230/400V AC|  | T2 Socket
FLWIN1102CSN00|  | 8033049748635|  | FIMER FLEXA AC Wallbox IN 11kW T2C|  | Inverter Net|  | 11 kW|  | 16A|  | 230/400V AC|  | T2 Cord
FLWFN1102SSN00|  | 8033049748642|  | FIMER FLEXA AC Wallbox FN 11kW T2S|  | Future Net|  | 11 kW|  | 16A|  | 230/400V AC|  | T2 Socket
FLWFN1102CSN00|  | 8033049748659|  | FIMER FLEXA AC Wallbox FN 11kW T2C|  | Future Net|  | 11 kW|  | 16A|  | 230/400V AC|  | T2 Cord
FLWSA2202SSN00|  | 8033049748666|  | FIMER FLEXA AC Wallbox SA 22kW T2S|  | Stand Alone|  | 22 kW|  | 32A|  | 230/400V AC|  | T2 Socket
FLWSA2202CSN00|  | 8033049748673|  | FIMER FLEXA AC Wallbox SA 22kW T2C|  | Stand Alone|  | 22 kW|  | 32A|  | 230/400V AC|  | T2 Cord
FLWIN2202SSN00|  | 8033049748680|  | FIMER FLEXA AC Wallbox IN 22kW T2S|  | Inverter Net|  | 22 kW|  | 32A|  | 230/400V AC|  | T2 Socket
FLWIN2202CSN00|  | 8033049748697|  | FIMER FLEXA AC Wallbox IN 22kW T2C|  | Inverter Net|  | 22 kW|  | 32A|  | 230/400V AC|  | T2 Cord
FLWFN2202SSN00|  | 8033049748703|  | FIMER FLEXA AC Wallbox FN 22kW T2S|  | Future Net|  | 22 kW|  | 32A|  | 230/400V AC|  | T2 Socket
FLWFN2202CSN00|  | 8033049748710|  | FIMER FLEXA AC Wallbox FN 22kW T2C|  | Future Net|  | 22 kW|  | 32A|  | 230/400V AC|  | T2 Cord

For more information, please contact a FIMER representative or visit: fimer.com

The company reserves the right to make technical changes or to modify the content of this document without prior notice. The agreed details concerning purchase orders apply. FIMER disclaims any responsibility for possible errors or lack of information herein.

The company reserves all rights to this document, the issues and the illustrations contained therein. Any reproduction, disclosure to third parties or use of the contents, in whole or in part, without prior written permission from FIMER, is prohibited. Copyright© 2021 FIMER. All rights reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FIMER User Manuals

Related Manuals