Landis Gyr AXei-SD Smart Meter for Landis+Gyr User Manual
- June 6, 2024
- Landis Gyr
Table of Contents
Landis Gyr AXei-SD Smart Meter for Landis+Gyr User Manual
Warranty
Limitation on Warranties and Liability
Information in this document is subject to change without notice. This manual or any part of it thereof may not bere produced in any form unless permitted by contract or by written permission of Landis+Gyr.
In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lostprofits) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages.
Covered by both issued and pending patents. For further patent information see: https://www.landisgyr.com/about/patent-notices/
© 2020 Landis+Gyr, Inc. | Proprietary + Confidential
Contact Us:
To provide feedback about this document, email us at
ustechnicaldocumentation@landisgyr.com
Technical Support: 1-888-390-5733 |
solutionsupport.na@landisgyr.com
Introduction
The AXei PCB contains two radios, a Zigbee radio and a Sub-GHz radio. The Zigbee radio on the AXei PCB is certified for modular approval.
The Sub-GHz radio is the S5-MCMO module. This radio complies with modular
approval by itself and has its own FCC and IC IDs. The S5-MCM0 is compatible
with Landis+Gyr Gridstream RF, Series 5 radios, operating in the unlicensed
sub-GHz frequency range of 902 – 928 MHz.
The S5-MCM0 module comes as a component on reel, conforming the LGA surface
mount package, and is intended to be placed on a host board using pick-n-place
technologies.
Both the Zigbee and the Sub-GHz radios are RF shielded metal shields as shown in the pictures below.
Figure 1. AXei PCBA
PCB F trace antenna is designed as part of the AXei host board for the Zigbee and SM-MCM0 radios, see the picture below. Refer to the D1432 PCB design file for the specific dimensional details. Each transmitter is certified with the intended trace antenna on the host board.
Figure 1. Antennas
The AXei PCB is designed to be mounted inside of the AXei meter forms specified in the table below, as final host. The PCB is mounted inside of the meter as shown in the picture below.
Figure 2. AXei PCB installation view
Figure 3. Representative meter
Host and Radio Characteristics
The table below contains information on the final host and the radios.
Category | Specification | Value or Range |
---|---|---|
Compatible Meters | Supported Meter Forms | Form |
1S | 120V |
100A
240V
2S| 240V| 200A
320A
3S| 120V| 20A
240V
4S| 240V| 20A
12S| 120V| 200A
240V| 320A
25S| 120V| 200A
240V| 320A
Electrical| Voltage| As listed above ±20%
Typical Burden (Rx at nominal voltage)| Less than 3.0 VA
900 MHz Radio (S5-MCM0)| Output Power| +27 dBm (500 mW) Max
Transmit Frequency| 902.2 – 927.8MHz
Communication Protocol| Frequency Hopping Spread Spectrum
Receive Sensitivity| -103 dBm to – 113 dBm (9.6 kbps to 115.2 kbps)
Data Rates| 9.6 – 115.2 kbps
Modulation| 2-FSK and 2-GFSK
RF ZigBee| Output Power| +20 dBm Max
Transmit Frequency| 2405-2475 MHz
Communication Protocol| ZigBee Protocol
Receive Sensitivity| -104 dBm typical
Environmental| Operating Temperature Range| -40 to +85C (under cover)
Humidity| 95% relative humidity, non-condensing
Table 1. Host and radio characteristics
FCC Statement
Federal Communications Commission (FCC) Compliance
Notice
This device complies with Part 15 of the FCC rules. Operation issubject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Consult Landis+Gyr or an experienced radio technician for help
WARNING: Changes or modifications to this device not expressly approved by Landis+Gyrcould void the user’s authority to operate the equipment.
Industry Canada (IC) Compliance Notice
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
RF Exposure
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
FCC and IC Label Requirements
The AXei Zigbee radio is certified as limited modular approval. In the final assembly or host, a label with the following information must be visible on the outside.
CONTAINS FCC ID: R7PNG0R1S7
CONTAINS IC: 5294A-NG0R1S7
The figure below demonstrates a label that complies to the labeling requirement for a host.
Figure 4. AXei meter label