GALLAGHER S10 Portable Solar Fence Energizer Instructions
- June 6, 2024
- GALLAGHER
Table of Contents
PORTABLE SOLAR FENCE ENERGIZER S0
Instructions
PUBLISHED BY Gallagher Group Limited Kahikatea Drive,
Private Bag 3026 Hamilton, New Zealand
www.gallagher.com Copyright © Gallagher Group
Limited 2021.
All rights reserved. Patents Pending. Gallagher S10
Portable Solar Fence Energizer
User Manual 3E3783 –
Edition 8 – May 2021
DISCLAIMER
Whilst every effort has been made to ensure accuracy, neither Gallagher
Group Limited nor any employee of the company shall be liable on any ground
whatsoever to any party in respect of decisions or actions they may make as a
result of using this information.
In accordance with the Gallagher policy of continuing development, design and
specifications are subject to change without notice.
Developed and manufactured by Gallagher Group Limited, an ISO 9001:2000
Certified Supplier.
IMPORTANT INFORMATION
Warning: Read all instructions
- WARNING – Do not connect to mains-operated equipment.
- Avoid contacting the electric fence wires with the head, mouth, neck, or torso. Do not climb over, through or under a multiwire electric fence.
- Use a gate or a specially designed crossing point.
- Do NOT become entangled in the fence. Avoid electric fence constructions that are likely to lead to the entanglement of animals or persons.
- Electric animal fences shall be installed and operated so that they cause no electrical hazard to persons, animals, or their surroundings.
- It is recommended that, in all areas where there is a likely presence of unsupervised children who will be unaware of the dangers of electric fencing, that a suitably rated current limiting device having a resistance of not less than 500 ohms be connected between the energizer and the electric fence in this area.
- The appliance is not intended for use by young children or infirm persons without supervision.
- Young children should be supervised to ensure that they do not play with the appliance.
- Well-maintained electric fences kept clear of vegetation with high-quality insulation are extremely unlikely to cause fires. In times of extreme fire risk, disconnect the energizer.
- Refer servicing to a Gallagher Authorised Service Centre.
- Check your local council for specific regulations.
- An electric animal fence shall not be supplied from two separate energizers or from independent fence circuits of the same energizer.
- For any two separate electric animal fences, each supplied from a separate energizer independently timed, the distance between the wires of the two electric animal fences shall be at least 2.5m. If this gap is to be closed, this shall be effected by means of an electrically non-conductive material or an isolated metal barrier.
- Barbed wire or razor wire shall not be electrified by an energizer.
- A non-electrified fence incorporating barbed wire or razor wire may be used to support one or more off-set electrified wires of an electric animal fence.
- The supporting devices for the electrified wires shall be constructed so as to ensure that these wires are positioned at a minimum distance of 150 mm from the vertical plane of the non-electrified wires. The barbed wire and razor wire shall be earthed at regular intervals.
- Follow the energizer manufacturer’s recommendations regarding earthing. · Do not install an earth (ground) system for your electric fence within 10 m (33 ft) of any power, telecommunications, or another system.
- Except for low output battery-operated energizers, the energizer earth stake should penetrate the ground to a depth of at least 1 m (3 ft).
- Use high voltage lead-out cable in buildings to effectively insulate from the earthed structural parts of the building and where soil could corrode exposed galvanized wire. Do not use household electrical cable.
- Connecting leads that are run underground shall be run in a conduit of insulating material or else insulated high voltage readout cable shall be used.
- Care must be taken to avoid damage to the connecting leads due to the effects of animal hooves or tractor wheels sinking into the ground.
- Connecting leads shall not be installed in the same conduit as the main supply wiring, communication cables, or data cables.
- Connecting leads and electric animal fence wires shall not cross above overhead power or communication lines.
- Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be avoided it shall be made underneath the power line and as nearly as possible at right angles to it.
- If connecting leads and electric animal fence wires are installed near an overhead power line, the clearances shall not be less than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Power line Voltage V | Clearance m |
---|---|
Less than or equal to 1 000 | 3 |
Greater than 1 000 and less than or equal to 33 000 | 4 |
Greater than 33 000 | 8 |
-
If connecting leads and electric animal fence wires are installed near an overhead power line, their height above the ground shall not exceed 3 m. This height applies either side of the orthogonal projection of the outermost conductors of the power line on the ground surface, for a distance of
– 2 m for power lines operating at a nominal voltage not exceeding 1 000 V;
– 15 m for power lines operating at a nominal voltage exceeding 1 000 V. -
Electric animal fences intended for deterring birds, household pet containment, or training animals such as cows need only be supplied from low output energizers to obtain satisfactory and safe performance.
-
In electric animal fences intended for deterring birds from roosting on buildings, no electric fence wire shall be connected to an earth stake. A warning sign shall be fitted to every point where persons may gain ready access to the conductors.
-
Fence wiring should be installed well away from any telephone or telegraph line or radio aerial.
-
Where an electric animal fence crosses a public pathway, a non-electrified gate shall be incorporated in the electric animal fence at that point or a crossing by means of stiles shall be provided. At any such crossing, the adjacent electrified wires shall carry warning signs.
-
Any part of an electric animal fence that is installed along a public road or pathway shall be identified by electric fence warning signs (G6020) at regular intervals that are securely fastened to the fence posts or firmly clamped to the fence wires.
-
The size of the warning sign shall be at least 100mm x 200mm.
-
The background color of both sides of the warning sign shall be yellow. The inscription on the sign shall be black and shall be either:
– the substance of “CAUTION: Electric Fence” or,
– the symbol is shown: -
The inscription shall be indelible, inscribed on both sides of the warning sign, and have a height of at least 25mm.
-
Ensure that all mains operated, ancillary equipment connected to the electric animal fence circuit provides a degree of isolation between the fence circuit and the supply mains equivalent to that provided by the energizer.
-
Protection from the weather shall be provided for the ancillary equipment unless this equipment is certified by the manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of protection IPX4.
This energizer complies with international safety regulations and is
manufactured to international standards. Gallagher reserves the right to make
changes without notice to any product specification to improve reliability,
function, or design. E & OE.
The author thanks the International Electrotechnical Commission (IEC) for
permission to reproduce Information from its International Publication
60335-2-76 ed.2.0 (2002). All such extracts are copyright of IEC, Geneva,
Switzerland. All rights reserved. Further information on the IEC is available
from www.iec.ch. IEC has no responsibility for the placement and context in
which the extracts and contents are reproduced by the author, nor is IEC in
any way responsible for the other content or accuracy therein.
OVERVIEW
1 | Battery indicator | Green | Battery OK |
---|---|---|---|
Red | The battery needs maintenance. See “Tips & troubleshooting” (p. 10) | ||
2 | On/Off | ||
3 | Solar Panel | Keep clean so the battery will charge from the sun | |
4 | Fence Terminal | Connects to fence | |
5 | Earth Terminal | Connects to earth/ground stake | |
6 | Mounting holes | ||
7 | Battery Access | Undo screw to access the battery (Battery needs connecting |
before first use)
8| Steel Post Mount| Allows for 360° mounting on T-Post, V-Post or similar
INSTALLATION INSTRUCTIONS
-
Open the energize r
-
Connect the battery
-
Close cover and tighten the screw
-
Install energizer
The solar panel should face towards the equator. i.e. in the northern
! x hemisphere, panel faces south, in the southern hemisphere, panel faces north. Avoid placing in a shady area. CAUTION: Do not install an energizer on the ground. -
Connect leads
a) Connect a green terminal to earth
b) Connect a red terminal to the fence line. -
Switch energizer ON
Note: The energizer will automatically slow the pulse rate at night to conserve the battery while livestock are less active.
Battery indicator | Description |
---|---|
Green flashing | The battery is OK and energizer working normally. |
Red flashing | Battery capacity is low due to insufficient sunlight. The |
energizer will slow down to use less power and allow the battery to charge.
CAUTION: Never leave the energizer face down.
TIPS & TROUBLESHOOTING
- Install an energizer where it can get plenty of sunlight.
- Install solar energizers on a post above the ground.
- Keep solar panel surface clean – periodically use a soft cloth with water and a mild detergent.
- Test voltage on the fence using a Gallagher Fence Volt Meter (G50301).
Problem | Solutions |
---|---|
Indicator flashing red | Ensure energizer is getting enough sun |
Turn the energizer OFF for 3 days, leave it in the sun to charge the battery.
Remove the battery and use a 6 V 1.2 A charger to charge the battery.
| Perform the above steps.
Replace battery.
| Check energizer isn’t faulty;
– disconnect from fence and earth
– measure across fence and earth terminals with a Gallagher Fence Volt Meter
– if less than 5 kV return energizer for service
– if more than 5 kV the fault is with the fence or earth system.
Note: Approvals & Standards – FCC
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
IMPORTANT BATTERY INFORMATION
Recharging the battery| Switch the energizer off. Place in sunlight for 3 days
with the battery connected OR remove the battery from the energizer and charge
the battery for 24 hours with a 6 V 1.2 A battery charger.
---|---
Storing the energizer| Switch the energizer off. Store in a well-lit area so
solar panel keeps battery charged. Recharge battery before and after storage.
Maintenance-free battery| The battery must not be opened and does not require
maintenance.
Battery replacement| Use only 6 V 4 Ah sealed, valve regulated (VRLA)
batteries.
Removing the battery| Switch the energizer off before removing the battery.
Disposing of the energizer| The battery must be removed from the energizer
before the energizer is disposed of.
Disposing of the battery| Lead-acid batteries must be disposed of safely
according to local regulations.
PRODUCT SPECIFICATIONS
Battery | 6 V 4 Ah sealed lead-acid (2M1847) |
---|---|
Current draw | 21 mA |
Stored energy | 0.16 J |
Output energy | 0.13 J |
OPTIONAL ACCESSORY
Install the energizer on a Gallagher Ring Top Post using the optional S10 Post Mount.
WARRANTY
Register your product online at
www.gallagherams.com and receive the following
benefits:
- Helpful customer service and technical support.
- A record that can help if your product is lost or stolen.
- Notification of special offers and product updates (optional).
2 YEAR WARRANTY for this product from the date of purchase. A dated sales receipt/invoice is essential for any future warranty claim. In addition please complete the details below and keep this card OR simply register your product online at www.gallagherams.com.
Model……………………………………………
Purchase Date………………………………………….
Serial No……………………………………………..
Dealer………………………………………………………….
WARRANTY CONDITIONS
This product is guaranteed free from defects in material or workmanship for a
period of two years from the date of purchase by the end-user. This excludes
any consumables provided with, or inside, the product where the warranty
period is 90 days (e.g. cleaning materials; batteries – rechargeable and non-
rechargeable; etc.). Gallagher will repair or
replace at their option any faulty product returned to them or their Dealer
within this time period.
Exchange modules are guaranteed for 90 days from date-of-fitting.
This warranty does not cover damage due to: incorrect input voltage,
contamination by battery acid, physical mishandling, lightning strike, water
immersion, damage to external wiring. Gallagher, their Distributors and their
Dealers accept no responsibility for the misuse of this product or for any
accident caused by tampering with or modification to or misuse of this
product. This does not affect your statutory rights.
References
- Product Registration - Gallagher Animal Management Systems
- Gallagher Group Limited
- Product Registration - Gallagher Animal Management Systems
- Homepage
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>