allerair A5AS61218110 AirMedic Pro 5 Ultra VOG Air Purifier User Manual
- June 6, 2024
- allerair
Table of Contents
AIRMEDIC PRO 5/6 SERIES
USER MANUAL
Changing lives through cleaner air (Since 1996).
Congratulations!
“ You are moments away from fresher, cleaner indoor air. Your new AllerAir unit will combat many of the chemicals, gases, odors, and particles responsible for poor indoor air quality (IAQ). Poor IAQ may cause or worsen allergies, asthma, multiple chemical sensitivity (MCS), and sick building syndrome. We recommend proper maintenance of your unit to keep it running efficiently for years to come.”
Allerair Team
Allerair air purifi ers play a valuable role in helping improve indoor air quality. To achieve optimal results air cleaning should be used in conjunction with pollution source control and ventilation, wherever possible.
Ways to improve indoor air
Control the source of the air pollutant by eliminating or reducing it as much as possible.
Ventilate your environment by introducing outdoor fresh air regularly.
Stand alone air purifi ers are not designed to replenish the oxygen level
indoors or eliminate carbon monoxide. They cycle the air within the space
reducing the VOCs, dust and other pollutants.* When allowing fresh air you are
allowing in oxygen into the environment for better breathing.**
AllerAir recommends a minimum of two air exchanges per hour. This has a direct infl uence on the size and/or the number of air purifi ers required for optimum indoor filtration. To ensure you have the proper levels of air turnover please contact AllerAir with the volume of your indoor space.
Improvement in indoor air quality by using AllerAir units depends to a signifi cant degree on circumstantial factors which are out of the control of the manufacturer or distributors. For specifi c indoor environments and to deal with particular air quality problems, the manufacturer and/ or distributors make no claim as to the air cleaning results that are accomplished under the user’s individual operating circumstances.***
- Contact Allerair for more information on the diff event types of pollutants
** Air purifi ers do not create fresh oxygen.
*** Based on the environment, level, and type of pollutants results may vary.
AirMedic Pro 5/6
AirMedic Pro 5/6 Plus/HD/Ultra
Replacement Filter Guide
Filter| Types and sizes|
Recommended replacement
---|---|---
Pre – filter| Regular| 2-3 months
Tar- Trap
MCS filter
HEPA| MG HEPA| 2-3 Years
SUPER HEPA| 1 – 2 years-
Activated Carbon| 2.5″ Carbon filter| 2-3 years — [ shelf life 5
years]
3″ Plus Carbon filter
3.5″ HD Carbon filter
5″ Ultra Carbon filter
UV| UV-C Germicidal lamp| 16000 hours or 1 year
‘ Recommended to change with the Carbon filter
” Every application is different when it comes to maintenance. For best
performance change every 1-2 years. Carbon shelf life is up to 5 years.
TO ORDER :
CALL ALLERAIR TOLL-FREE 1-888-852-8247
EMAIL US AT: SALES@ALLERAIR.COM
OR FILL OUT OUR ONLINE FILTER FORM
AirMedic Pro 5/6 Quick Pre-fi later Replacement
STEP 1
Turn the unit OFF, unplug it, and gently lay it on its side.| STEP 2
Slowly remove the dirty pre-filater to avoid dispersing its contents.| STEP
3
Insert the new pre-filter and press it outwards to occupy the available space
against the carbon filter. Return the unit to an upright position.
AirMedic Pro 5/6
HEPA & Carbon filter Replacement
STEP 1
Make sure the unit is Turned OFF and the unit is unplugged. Place the unit
upside down, so that the wheels face up.
STEP 2
Using a #2 Philips screwdriver, remove the four screws that hold the base onto
the unit.
STEP 3
Grab the wheels. Remove the base by pulling gently on the wheels.
STEP 4
Remove the gasket to access the filters.
STEP 5
Reach inside the unit, and remove the HEPA & Activated Carbon filter by pulling
them upwards.
Note that there should be one gasket located at the bottom of the filters.
STEP 6
Place the new HEPA & Activated Carbon filter inside. Ensure that there is one
gasket at the bottom of the filters.
STEP 7
Put back the gasket removed in STEP 4.
STEP 8
Place the base back, making sure the arrow on the sticker lines up with the
unit’s rear seam.
STEP 9
Using a #2 Philips screwdriver, install the four screws to hold the base onto
the unit.
STEP 10
Flip the unit back in its upright position. Plug it in and run it on high for
a few minutes then set it to your desired speed.
AirMedic Pro 5/6 Plus/HD/Ultra
SuperHEPA & Carbon Filter Replacement
STEP 1
Follow steps 1-4 from [AirMedic Pro 5/6 HEPA & Carbon filter Replacement] to
access the filters.
STEP 2A
Remove the carbon filter along with the SuperHEPA filter. (Follow STEP 2B if you
have the Ultra 5” filter)
STEP 2B
Using the two straps on the sides of the 5” Ultra Carbon filter pull/ lift up
both Carbon and SuperHEPA filter together.
AirMedic Pro 5/6 PLus/HD/Ultra
SuperHEPA filter Replacement
NOTE: SuperHEPA is pre-installed by Allerair when you place to purchase both Carbon and SupeHEPA together.
STEP 1
Follow steps 1-4 from [AirMedic Pro 5/6 HEPA & Carbon filter Replacement] to
access the filters. Remove green velcro straps
STEP 2
Remove the old SuperHEPA by unwrapping it from around the Carbon filter. (DO
NOT Remove the thinner layer of carbon wrap from around the carbon filter)
STEP 3
Wrap the SuperHEPA around the carbon filter by rolling the canister onto the
Superhepa to ensure it is tight. Remove the sticker off the double-sided tape
of the SuperHEPA and secure it in place.
STEP 4
Re-attach the green velcro straps that were removed in step 1
STEP 5
Put the Carbon with the SuperHEPA filter back in the unit.
STEP 6
Place the Gasket back on the top and close up the unit.
AirMedic Pro 5/6 & PLus/HD/Ultra
UV-C light Replacement
STEP 1
Follow steps 1-5 from [AirMedic Pro 5/6 HEPA & Carbon filter Replacement] and
remove the bottom gasket to access the separator plate.
STEP 2
Using a #2 Philips screwdriver, remove the three screws holding the separator
plate to access the UV light.
STEP 3
locate the UV-C light bulb. Using a #2 Philips Screwdriver, remove the screw
and nut that is holding the UV bulb down as demonstrated in step 4.
STEP 4
Unplug the UV-C bulb from its socket to replace it with the new one.
Note: do not apply force as you may risk breaking the bulb or the pins.
Tips
Replacing the filters will extend the life of your AllerAir unit. Be sure to
follow the Replacement Filter Guide on page 5 to replace your filters.
Place the unit near the source of the Contaminants.
Keep the unit running 24/7 on the lowest setting.
Particles paint may clog your HEPA filter, therefore we recommend that users
unplug their units and remove the HEPA filter, storing it off -site until the
paint job is complete. Due to the serious toxic nature of paint, it is also
recommended that your carbon filter be replaced orrefilled in the weeks after
the paint job is complete.
THE ALLERAIR AIR FILTRATION SYSTEM
ACTIVATED CARBON
Your AllerAir air purifi er contains activated carbon that traps dangerous
airborne chemicals, gases, and odors. This vital filter should be changed
approximately every two to three years, depending on the environment in which
the unit is operating. You can also upgrade your unit at any time to
accommodate a larger and deeper bed carbon filter that is suitable for removing
heavier concentrations of chemicals, gases, and odors.
PRE-FILTER
The pre-filter included with your unit removes larger particles and helps
prolong the life of your HEPA filter. The pre-filer should be replaced every two
to three months.
HEPA
HEPA or high-efficiency particulate air filters were originally developed by the
military to remove radio-active dust, and are now the primary particle
filtration systems used in hospitals, laboratories, electronic clean rooms, and
any application where clean air is critical. Today, HEPA filters are widely
recommended by allergists, doctors, and indoor air quality experts for home
and office. They trap an amazing 99.97% of airborne particles at 0.3 microns,
including dust, hair, pollen, and even some bacteria and viruses. SuperHEPA in
AllerAir units traps 99.99% of fine particles at 0.1 microns in size.
ENVIRONMENTS
The AllerAir advantage provides its users with easy and flexible customization
options. You can easily change your filters to suit your requirements and
needs by upgrading or reducing the filters within the same unit. Some sample
environments you can use your air purifi er in are living space, offi space,
smoking lounge, operatories, clinics, classrooms, salons, restaurants, shops,
gyms, studios, and many more…
WARRANTY
Your AllerAir unit comes with a 10-year limited warranty excluding expendable
parts such as pre-filters and filters. This warranty provides for the repair of
any defective components for 5 years from the date of delivery and includes
labor. An additional 5-year warranty is provided on parts. This product is not
covered against damage resulting from misuse. This warranty does not cover
damage, fault or failure due to alteration or repairs made by anyone other
than AllerAir or the use of supplies and accessories other than those
manufactured by AllerAir. This warranty is provided to the original purchaser
and may not be transferred. A return authorization number is required for
warranty repairs.
WARNING
NO USER-SERVICEABLE PARTS INSIDE.
RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS THROUGH MISUSE. THIS IS AN
ELECTRICAL APPLIANCE. IT IS NOT INTENDED FOR USE BY PERSONS (INCLUDING
CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF
EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN PRIOR INSTRUCTIONS
CONCERNING USE OF THE APPLIANCE OR THEY ARE BEING SUPERVISED BY A PERSON
RESPONSIBLE
FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE
APPLIANCE
DO NOT OPERATE ANY UNIT WITH A DAMAGED CORD OR PLUG. DISCARD UNIT
OR RETURN TO ALLERAIR FOR EXAMINATION AND/OR REPAIR.
REFRAIN FROM POKING OR STICKING ANY OBJECT INTO THE UNIT’S AIR VENT
DISCHARGE. DO NOT OBSTRUCT THE AIR INLET AND AIR OUTLET.
DO NOT USE ANY PARTS, ATTACHMENTS, OR FILTERS NOT RECOMMENDED BY ALLERAIR
DO NOT IMMERSE THE APPLIANCE IN WATER OR OTHER LIQUIDS.
DO NOT USE APPLIANCES IN ENVIRONMENTS WITH HIGH CONCENTRATIONS OF
DUSTY AND/OT POWDER.
DO NOT USE OUTDOORS.
DO NOT USE APPLIANCES IN EXPLOSIVE ENVIRONMENTS.
DO NOT PLACE IN HIGHLY HUMID ENVIRONMENTS OR NEXT TO A HUMIDIFIER.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
For more information please visit our website
www.Allerair.com or call us
Toll-free at 1-888-852-8247 you can
also email us at Info@allerair.com
NOTES:
MODEL NO #
SERIAL MO #
www.Allerair.com
1-888-852-8247
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>