CARSON MM-480 Digital Microscope User Guide
- June 6, 2024
- Carson
Table of Contents
- Important information
- Product description
- Computer requirements & Software Installation
- Package contents
- Product overview
- Product specifications
- Operation
- Connecting the device
- Using the xploview software
- Care and maintenance
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CARSON MM-480 Digital Microscope User Guide
Important information
Please read this instruction manual carefully before using this product, and retain this instruction for future reference.
Improvements and changes to this text necessitated by typographical errors, or improvements to the software and/or equipments may be made at any time without notice.
Product description
This product is a USB powered device which features an effective magnification of 65x on a 21″ computer monitor.
Capture an image to keep with the click of a button. You can even capture close-focus video!
Compatible with Mac and PC.
This item can be used with applications that support the viewing of USB video devices (these applications are not included). USB 2.0 required. No batteries required.
Computer requirements & Software Installation
Go to www.carson.com/software to download the latest software and corresponding software installation guide for the MM-480. The computer requirements (operating system, etc.) may be different depending on the software version.
Package contents
- Digital Microscope x1
- Adapter for face/scalp x1
- Adapter for nose/ears x1
Product overview
- Shutter Button
- Focusing Ring
- Lens
- LED Illumination
- Adapter slot
- USB Cable
Product specifications
Optical Specifications
Effective*
Magnification on 4:3 Reference Displays| 65x@21″ 85x@27″
---|---
Image Sensor Format| 2.0 MPixel UXGA CMOS
Image Resolution| 1600 X 1200 Pixels (UXGA)
Please note that the effective magnification is a combination of the optical system and a high powered digital zoom.
Power Ratings
Digital Microscope | 5V DC250mA (USB 2.0) |
---|
Physical Property
Net Weight | 104g |
---|---|
Approximate Dimensions | W50mm x D50mm x H74mm |
Operation
To view the images clearly, please use one of the adaptors provided.
Choose an adaptor, place it into the adaptor slot located under the main body.
Lock by turning in clockwise direction.
Connecting the device
Connect the device to the computer using the USB cable provided. The LED light will turn on indicating that the device is powered on.
When the device is connected to the computer for the first time, a driver will automatically be installed by Windows or Mac OS. This process could take up to a few minutes.
Focusing
Rotate the focusing ring clockwise or counterclockwise until the viewing image shown on the monitor is clear and sharp.
To capture an image, press the shutter button on top of the zOrb.
Using the xploview software
The following buttons are available:
| Clicking this will open the system settings menu (see next section).
---|---
| Clicking this will capture the on screen image of the device.
| Clicking this will activate or deactivate the timed shot feature. When activated, images will be captured at a regular interval.
| Clicking this will activate or deactivate the video recording feature.
| Clicking this will show the copyright and version information of the application software.
| Clicking this will shut down the application software.
System settings menu
The first time the xploview software is started, the default settings will be loaded, you may change these settings manually in the system settings menu.
Device setup
If the image captured by the Digital Microscope was not displayed by default, you can change this by selecting it from the “Device” drop-down menu.
The resolution of images you capture can be changed from the “Resolution” drop-down menu.
Timed shot setup
The frequency and duration of automatic images capture can be adjusted under this option.
Movie setup
The resolution of videos you record can be changed from the “Resolution” menu. You can also set a maximum file size for each video.
Save setting
The default location for captured images or videos can be changed under this option.
Language setting
The language of the xploview software can be changed under this option.
Advanced settings
By clicking the “More…” button on the right of the system settings menu, you will be able to manually adjust all of the image settings. Note that the settings available may be different, depending on your operating system.
Saved files
With the xploview application software opened, you can locate the saved files folder by clicking the “More…” button located on the left of the main software window.
Full screen
To activate the full screen mode, click the full screen button located on the bottom right hand corner of the xploview application software window.
To exit full screen mode, either double click on the screen, or press the “Esc” button on the keyboard.
Care and maintenance
- Keep the device dry and protect it from water or vapour.
- Do not leave your device in a place with an extreme high or low temperature.
- Do not touch the device with a wet hand as it may damage the device, or cause an electric shock to the user.
- Do not use or store the device in dusty, dirty areas as its moving parts may be damaged.
- Do not use harsh chemicals, cleaning solvents or strong detergents to clean the device. Wipe it with a soft cloth slightly dampened in a mild soap-and-water solution.
Warning
- Do not place lighted Digital Microscope upon the eye, doing so may cause permanent eye damage.
- Do not attempt to open or dismantle the Digital Microscope.