Shenzhen Fimi Robot Technology PALM 2 Gimbal Camera Instruction Manual

June 6, 2024
Shenzhen Fimi Robot Technology

PALM 2 Gimbal Camera User Manual
Please read this manual carefully before use

Product Introduction

Charging

To charge PALM2, please use the included USB cable to connect it with the USB-C port in maximum charging current of 5V2A. While charging, the status LED is always on. When the battery is fully charged,the status LED is off.

The equipment of external MIC

Pleasse equip the MIC as shown

Inserting the MicroSD

Card Please insert the MicroSD Card as shown. It is recommended to use a microSD card with or over a UHS- Ill Speed Grade 3 rating. The PALM 2 supports atmost SD card with 256G(not included), and you can format the SD card on PALM 2.

Operations

  1. Power/Shutter Button
    Status| Instruction
    ---|---
    Long press| Turn on or tum off the PALM
    Short press| Take a capture according to current shooting mode
    Double dick| To recenter the gimbal

  2. Direction joystick
    Status| Instruction| Remarks
    ---|---|---
    Move up| To control the gimbal camera move up| Mode 1
    Move down| To control the gimbal camera move down| Mode 1
    Move left| To control the gimbal camera move left| Mode 1
    Move right| To control the gimbal camera move right| Mode 1
    Move up| ZOOM +| Mode 2
    Move down| ZOOM –| Mode 2
    Move left| EV –| Mode 2
    Move right| EV+| Mode 2

P.S. Click the ” ” on the top right of screen to switch mode 1 and mode 2.

  1. Touch Screen
    Status| Instruction
    ---|---
    Swipe right/left| To switch shooting mode
    Swipe down| To enter setting mode
    Swipe up| To enter media library
    Double dick| Turn on / turn off Face Tracking
    Double dick the selfie button| To switch selfie mode
    Long click the selfie button| To center the gimbal

  2. Status LED
    Status| Instruction
    ---|---
    Green light is on| Normal
    Green light flashes| Recording
    Red light is on| Low battery or the gimbal is abnormal
    Red light flashes| System is abnormal
    Red and green light alternative& flash| Firmware is updating

Downloading APP

Please scan the QR code or search for downloading the FIMI PLAY APP in APP Store or Google Play

https://fimiservice-newus.mi-ae.com/v1/app/update/gh4/down.html

Maintenance and Calibration

  1. The PALM 2 enters the self-check when it is powering.
  2. Gimbal camera is a high-precision control device. Please do not drop it or have it hit by external force. And please ensure that the gimbal doesn’t be blocked by outside forces when it is moving. Otherwise, the machine might be damaged and be led to abnormal operations.
  3. Do not place the battery near heat. Lithium battery’s capacity reduces significantly in low temperature conditions. Please do not use the PALM 2 if the temperature is below 0 celsius degree.

Basic Specification

Name: PALM 2 Gimbal Camera
Model: YTXJ06FM
Dismensions: 32.535.5132.5mm
Net Weight: 145g (accessories are not included)
Precision Control: ± 0.005°
Rolling Angle: YAW: -240° ∼ + 60° ROLL: ± 45° PITCH: ± 90°
Battery Capacity: 2600 mAh
Rated Power: 9.62 W
Rated Voltage: 3.7V
Operating Temperature: 0°C∼40°C
Wireless Connectivity: Wi-Fi IEEE 802.11b/g/n
Product standard: Q/BJFMK0006-2017
Check more detailed information in setting

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • this device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation.

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.

The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Manufacturer: Shenzhen Fimi Robot Technology Co., Ltd.
(a Mi Ecosystem company)
Address: 2nd Floor, East Block, Tianliao Building, 1133
Xueyuan Avenue, Xili Town, Nanshan District, Shenzhen
City, China
Official website: www.fimi.com
Online service: [email protected]
TEL: 400-661-0908

FCC statement

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.

This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

–Reorient or relocate the receiving antenna.
–Increase the separation between the equipment and receiver.
–Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
–Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC Radiation Exposure Statement

This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

This model product has been tested and meets the FCC RF exposure guidelines with the test distance 20mm for body worn

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Shenzhen Fimi Robot Technology User Manuals

Related Manuals