merrytek MC054V- RC- 2A Lighting Control Switch User Manual
- June 6, 2024
- merrytek
Table of Contents
merrytek MC054V- RC- 2A Lighting Control Switch
Features
- Operating vol tage 120~277V AC, suit able to Euro & North American market.
- Patented microwave antenna, mounting height is 15m Max, suitable to install in most of the warehouses.
- Supports high-sensitivity and low-sensitivity modes (for metal ceilings, metal reflector mounting environments)
- Work with 1-10V dimmable LED driver, easy to achieve 2-step or 3-step dimming function.
- New patented remote control to adjust the transmitting angle to avoid misuse.
- 5 years warranty
Parameter
Input
| Operating Voltage Rage| 108-305V AC, 50Hz/60Hz
---|---|---
DC Input Voltage| N/A
Rated Voltage| 120/277Vac,60Hz
No-load Power| N/A
Stand-by Power| <1W
Surge Test| L–N: 1kV
Output
| Working Mode| ON/OFF function, 1-10V step dimming
Type of Load| Inductive or resistive Load
Load Capacity| 120VAC: 4A; 277VAC: 3A
Current of Load| N/A
Max. Surge Capacity| 50A (50% Ipeak, twidth =500uS, 230Vac full load, cold
start);
80A (50% Ipeak, twidth =200uS, 230Vac, full load, cold start)
Dim Interface
| ****
1-10V Dimming
| < 50mA (Non-constant source) 10%(1.4-1.6V), 20%(1.9-2.1V),
30%(2.9-3.1V), 50% (4.9-5.1V)
Synchronous Control| N/A
High Low-level| N/A
PWM Control| N/A
Sensor
Parameters
| Operating Frequency| 5.8 GHz ±75 MHz, ISM Band.
Transmitting power| 0.5mW Max.
| Hold time| 5s/30s/1min/3min/5min/10min/20min/30min
---|---|---
Stand-by DIM Level| 10%/20%/30%/50%
Stand-by Period| 0s/10s/1min/3min/5min/10min/30min/+∞
Detection Area| 25%/50%/75%/100%
****| 5lux/15lux/30lux/50lux/100lux/150lux/Disable (Ambient light
diffusion)
Detecting Radius| See note 2
Mounting Height| 15m Max
Detecting Angle| 150°(wall mounting), 360°(ceiling mounting)
Wireless Module
| Operating Frequency| N/A
Transmitting power| N/A
Transmitting distance| N/A
Modulation mode| N/A
Number of coding| N/A
Operating Environment
| Operating Temperature| -35℃…+55℃
Storage Temperature| Temperature:-40℃…+80℃;Humidity:10%-95%
(non-condensing)
Certificate Standards
| ****
Safety standards
| IEC60669-2-1, IEC60669-1
AS/NZS 60669.1, AS/NZS 60669.2.1 UL60730-1
EMC standards
| EN55015, EN61000-3-2, EN61000-3-3, EN61547 AS/NZS CISPR 15, AS/NZS 4268
FCC Part 15C, Part 15B
EN 60950-1, EN301489-1, EN 201489-3, EN300440
Environmental Requirem
ent
| Compliant to RoHS
Certificate| cULus, CE, SAA, FCC, RED
Others
| Wiring| SJTW,518AWG (USA); H05RR-F,518AWG (Europe,Australi
a); exposed line length: 810-830mm
Wiring color| Sheath: Black Core: Red,White,Black,Gray,Purple (US);
blue, brown, red, purple,Gray (Europe, Australia)
IP Rating| IP65
Protection Class| Class II
Installation| Independent
Dimension| (ΦxH)72*59mm
Package| Instruction+ White box+ White box tags+ Clapboard+
Carton(K=A)
Net Weight| MC054V RC A: 225g, MC054V RC B:246g,
MC054V RC C:225g , MC054V RC D:165g
Lifetime| 5 years warranty @Ta 230V full load
Note
- “N/A” means not available.
- Detection area is affected on the volume of moving object and motion speed.
- The detection area is tested by a 165cm height person and the walking speed is 0.5m/s.
FUNCTION
Func tion1) On/OFF Function (stand-by period be set to “0”s)
2-step dimming function (stand-by period be set to “+∞”)
3-step dimming function (stand-by period be set to “10s/1min/3min/5min/10min/30min”)
Dimension (mm)
MC054V- RC- 2 A,MC054V- RC- 2B, MC054V-RC- 2C
MC054V- RC- 2D
Wiring
(Europe,Australia version)
(USA version)
The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
Function Diagram
Radiation Pattern
- Ceiling mounting Ceiling mounted height: 3m Sensitivity: 100%/75%/50%/25%
- Ceiling mounted height: 6m Sensitivity: 100%/75%/50%/25%
- Ceiling mounted height: 9m Sensitivity: 100%/75%/50%/25%
- Ceiling mounted height: 12m Sensitivity: 100%/75%/50%
- Ceiling mounted height: 12m Sensitivity: 100%/75%/50%
Lighting Control Switch
- Slow-moving: (Speed 0.3m/s)
- Slow-moving:Speed: 0.3m/s)
- Slow-moving: (Speed: 0.3m/s)
- Slow-moving: (Speed: 0.3m/s)
- Slow-moving: (Speed: 0.3m/s)
*Only 100%/75%/50% detection sensitivity is workable when installed at 10m & 15m mounting height. 25% sensitivity is not able to detect motion signal.
Wall mounting
Horizon mounted height: 2m Sensitivity: 100%/75%/50%/25%
Remote Control
- Press the “ON/OFF” button, the light goes to constant on/off mode, sensor Is= disabled. Press “Reset” “Sensor motion· button to quit from this mode and the sensor starts to work.
- Press • Reset” button, all parameters are the same as setting of factory settings.
- Press the “Sensor motion• button, the light quits from the constant on/ off mode, and the sensor starts to work ( The latest sett. ing stays In valid)
- Press• DIM Test” button, the 1-10 V dimming works to test whether the 1-10Vdc dimming ports are connected properly. After 2s, It returns to the latest setting automatically.
- ·override DH”, and • DH Mode” that the two functions are not applicable for MC054V RC2.
Note : Detection area/ Hold t,me /Stand-by period /Stand-by dim level/ The daylight sensor can be adjusted by pressing the corresponding button. The latest setting will stay valid.
-
Press the “TEST 2s• Bolton can enter the test mode at any time. At the mode, the sensor parameters as below: Detection Area is 100%, Hold nme is 5s, Stand-by
The dim level is 10%, Stand-by Period is Os, daylight sensor is disable. This function only for testing. Quit the mode by pressing • RESET” or any other function buttons. -
Press the “HS” button lo set the detection area to be highly sensitive.
-
Press the “LS” button to set the detection area to below sensitive.
-
The adjustment bases on the • Detection Area• parameter you set.
-
Daylight Sensor
Set up daylight threshold:
5lux/15lux/30Lux/50Lux/100Lux/150Lux/ Disable. -
Stand-by period
Set up stand-by time: OS/10S/1min/3min/5min/10min/30min/+oo -
Hold time
Set up hold time: 5S/30S/1mln/3mln/5mln/10mln/20mln/30mln -
Stand-by dim level
Set up a stand-by dim level: 10%120%/30%/50% -
Detection Area
Set up detection area: 25%/50%/75%/100% -
Remote Distance
The toggle button can set the remote distance of the remote control and sensor.
Initialization
-
1/ On/Off function /3-step dimming function:
After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement. -
2/ 2-step dimming function:
After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it dims the light to a low light level (set by stand-by dim level). During the initialization, the sensor is not able to detect movement.
Factory Setting
Detection area: 100%, Hold Time: 5S, Stand-by Period: 0s, Stand-by dim level:
10%, Daylight Sensor: Disable
Application Notice
- The sensor should be installed by a professional electrician. Please turn off the power before installing, wiring,changing the setting of the DIP switch.
- The sensor which installed in the plastic and glass lampshade will reduce the sensitivity.For every 3mm increase in thickness, the sensitivity will be reduced by 20%.
- The dimming performance could be different from different 1-10v drivers.
- The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection..Ambient lux level could be different in different environments, weather, climate, time-of-day and season.
- The parameters of the sensor may need to be reconfigured in different installation environments. Please refer to the following instructions or contact the manufacturer.
- This sensor is for indoor use only. It will affect the waterproof effect for outdoor use. Wind, rain, and moving objects around will cause false triggering.
- The distance between any inductive sensors should be greater than 3m.
- Do not place the sensor close to high-density objects such as metal, glass,concrete walls, etc, false triggering could happen. When the sensor is installed in a metal lamp, metal reflective surface, or a narrow enclosed environment, the microwave will be reflected repeatedly and cause false triggering. Please reduce the sensitivity or contact the manufacturer for technical support.
- Please ensure that there are no moving signals around the sensor, such as fan,DC motor, sewer pipe, air outlet, etc., the sensor may generate false trigger.
- You are advised to test 5 samples before mass application of sensor in a new lighting project.
- Due to continuous improvement, the contents of this instruction could be changed without prior notice.
FCC Statement
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.
Version Change
Version | Date | Description |
---|---|---|
A0 | March 14, 2019 | Released new product |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>