4GLTE LTE Indoor CPE Router Modem User Manual
- June 6, 2024
- 4GLTE
Table of Contents
4GLTE LTE Indoor CPE Router Modem
Get to know your LTE Indoor CPE
Application
Access to internet by Ethernet
Notice: Place the device on a stable surface.
- Open the packing box, insert the power adapter into the power port of CPE.
- After power on, all indicators will on, then power indicator steady on, WiFi indicator steady on;
- Connect the WAN port to Ethernet port, WAN indicator will steady on, it will blinking once data is being transmitted.
- Connect the LAN port to the end device, LAN indicator will steady on, it will blinking once data is being transmitted.
Or connect the end device through WiFi, WiFi indicator will blinking once data is being transmitted.
Access to internet through 4G network:
Notice: Place the device on a stable surface.
- Slide off the card slot cover, insert the standard Micro SIM card as following picture:
- Open the packing box, insert the power adapter into the power port of CPE;
- After power on, all indicators will on, then power indicator steady on, WiFi indicator steady on;
- 4G CPE will automatically dial-up, 4G indicator steady on, then blinking, it means the device already connect with Internet
Set up a WiFi connection
- Make sure CPE is turned on, and WiFi is on working;
- Power on the end device to enter the WiFi setting;
- Click the SSID of CPE, SSID and password are on the sticker of CPE, refer to the right picture; SSID:4G-CPE-xxxxxx Wifi-key:A1b2c3d4
- Enter WiFi password, click connect, WiFi connection is successful after WiFi indicator blinking.
(The WiFi setting interface is different for different end devices, refer to the following device)
Login WEB UI
- Make sure the 4GCPE is poweron, and your com-puter and mobile phone connected with 4G CPE;
- Open the browser of com-puter or mobile phone;
- Enter the IP address into the address bar of browser, IP address is as right picture;
- IP: 192.168.100.1
- User: admin
- Password: admin
- Enter the user name and password into the prompt dialog box, user name and password are: admin;
- In the main menu of WEB UI, it including CPE status, router setting, WiFi setting,firewall, SMS setting, system management and etc;
- After finish the setting, click the apply, the device will restart automatically.
Main menu of WEB UI:
Faulty checking and Notices
Faulty checking:
- Power indicator is off, please check if you plug the power adapter properly.
- 4G indicator is off, please check if you insert SIM card properly.
- 3G/4G indicatordoesn’t blinking:
- a, It is searching for the internet while it steady on within 3 minutes;
- b, It can’t connect to internet while it steady on more than 3 minutes, please change the CPE into another place
Notices:
- Place the device on a stable surface.
- Ideal operating temperatures are 0℃ to 40℃, ideal storage temperatures are -20℃ to +70℃. Extreme heat or cold may damage your device or accessories.
- Keep the device away from sources of fire, water to avoid damage your device or accessories.
- Do not use your device during thunderstorms to protect your device against any danger caused by lighting.
- Do not bend or press the external antenna, otherwise, communication quality may be reduced.
FCC STATEMENT
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radiorrv technician for help
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment, In order to avoid the possibility of exceeding the
FCC radio frequency exposure limits.Human proximity to the antenna shall not
be less than 20cm (8 inches) during normal operation.