PRODUCT DESCRIPTION

PRODUCT DESCRIPTION
Battery Description

  1. Battery compartment
  2. 3/4” adaptor
  3. 1” Connection
  4. Filter
  5. LCD display
  6. Dial
  7. Dial position indicator
  8. + Button
  9. – Button
  10. Rain Delay Button
  11. Manual ON/OFF Button
  12. Cover
  13. Sensor Connection Socket

INSTALLATION

REFERENCE THE NUMBERED COMPONENTS WHEN READING INSTRUCTIONS

BATTERY COMPARTMENT

  1. Slide out the battery compartment 1 and insert 2 (LR6/AA) 1.5V alkaline batteries. (not included)

CAUTION: Use only fresh alkaline batteries at the beginning of the season. Do not use rechargeable batteries. When batteries are inserted, LCD display will show clock time. If not, check if the batteries are installed correctly. Turn Dial to OFF position before connecting it to the tap/spiggot.

CONNECTING YOUR TIMER TO THE SPIGOT

  1. To connect your timer to the spigot use 3/4’’ adaptor 2 or the 1’’ connector 3 .
  2. For 3/4’’ taps: install the timer onto the spigot with the 3/4’’ adaptor 2 included.
  3. For 1’’ taps: remove the 3/4’’ adaptor and attach the 1’’ connection 3 to the spigot directly. Note: always keep the filter 4 in place.

CAUTION: To avoid damage to the timer, tighten all connections by hand.

FILTER

The filter traps dirt particles and prolongs the life of timer.

CAUTION: Clean filter regularly and replace if worn.

LCD DISPLAY WARNING

When LCD display 5 shows a quick flashing “Low Battery” sign, remove the battery compartment 1 and wait for 60 seconds until screen clears before re-insert the new batteries.
LCD DISPLAY

Dial Position

|

Description

---|---
RUN| Settings confirmed and saved,timer run According  to settings
SET CLOCK| Set clock time (0:00-23:59)
START TIME| Set when to start watering (0:00-23:59)
HOW LONG| Set watering duration (0-360 mintues)
HOW OFTEN| Set watering frequency (1,2,4,12 hours or 1-7 days)
OFF| Turn timer off

8 + BUTTON & 9 – BUTTON

During settings, the number will change quickly if press and hold the + Button or – Button

10 RAIN DELAY BUTTON

When dial is at RUN position, press the rain delay button to set manual watering at 0, 24, 48 or 72 hours.

MANUAL ON/OFF BUTTON

When dial 6 is set in the RUN position, press the manual on/off button 11 to set manual watering from 0-240 minutes.

COVER 12

Keep cover closed to protect timer from dust and dirt.

SENSOR CONNECTION SOCKET 13

The socket is for rain sensor or moisture sensor connection, to skip watering during rainy days or when soil is too wet. (Sensor sold seperately).
SENSOR CONNECTION

MALE SNAP-ON CONNECTOR

Connect hose attachment to the male snap-on connector 14 at the bottom of the timer.

PROGRAMMING THE TIMER

SET CLOCK

Turn dial 6 to SET CLOCK position, press + Button 8 or – Button 9 to advance or reverse clock time (hold button for quick advance or reverse).

START TIME

  1. Turn dial 6 to START TIME position, press + Button 8 or – Button 9 to advance or reverse start time (hold button for quick advance or reverse).
    START TIME

Note: Start time is set in this situation

HOW LONG

  1. Turn dial 6 to HOW LONG position, press + Button 8 or – Button 9 to advance or reverse run time (hold button for quick advance or reverse). (0-360 minutes).
    HOW LONG

HOW OFTEN

  1. Turn dial 6 to HOW OFTEN position, press + Button 8 or – Button 9 to advance or reverse watering frequency (hold button for quick advance or reverse). (1,2,4,12 hours or 1-7 days)
    HOW OFTEN TIME

NOTE: HOW OFTEN SHOULD ALWAYS BE LONGER THAN HOW LONG (Example: How Often = 1 Hrs, How Long = 90 Mins, is NOT a valid setting.)

RUN

  1. Turn dial 6 to RUN position, to save settings. Timer waters according to programmed time, frequency and run time.
  2. Screen will flash between clock time and watering time.
    Tip: Take down notes of the settings for records or reference.
    RUN TIME TIPS

RAIN DELAY

  1. When dial 6 at RUN position and program saved, press the 10 button to delay for 0, 24, 48 or 72 hours.
  2. Screen will flash between clock time and hours remaining before program resumes.
  3. To remove rain delay, turn dial OFF to and then back to RUN.
    RAIN DELAY

MANUAL WATERING

Manual watering is for one time instant watering without interrupting the set program.

  1. Press the manual on/off button and then press the + Button 8 or – Button 9 to set from 0 to 240 minutes.
  2. Press L/R button 10 to choose Left or Right valve
  3. Manual watering will start within 5 seconds if no more change
  4. Screen will flash between clock time and minutes remaining before program resumes.
  5. To remove manual watering, turn dial 6 to OFF or simply press again the manual on/off button.
  6. To resume set program, turn the dial 6 back RUN.

CARING FOR YOUR TIMER

This timer is only designed for outdoor use to control sprinklers or irrigation systems for watering, and CAN NOT be used for industrial purposes which in contact with food, chemicals and pesticides.

Operating water pressure is from 7 psi to 116 psi. DO NOT connect direct to water tank which has lower pressure than 7 psi.

Use with clean and freshwater only with temperature above 34˚ F and below 140˚ F.

Protect timer during winter season or freezing conditions. Remove from tap and drain water inside, remove battery and keep indoors.

Your timer is water resistant, NOT water proof. The timer must be installed above ground and vertically to the tap. DO NOT submerge it in water. to avoid damage to timer, DO NOT pull the hose while attached to the timer.

If timer does not work, refer to instructions to confirm connections and intended use is appropriate. If timer continues to perform not as intended, contact the Chapin Customer Service/ Technical Support before returning to the store.
Icons

CAUTION

When connecting to a public water source, consult your local code. A backflow valve may be required. (Chapin backflow valves sold separately Models: 6-9089 or 6-9088).

Do not operate with water sources above 116 PSI without installing a water preassure regulator in-line before your water timer. Excessive pressure may cause damage to your Water timer.