Overview
The UPort 1100 series is part of Moxa’s UPort Line of USB-to-Serial adaptors.
The UPort product line provides a wide range of easy-to-use solutions for
adding Windows COM ports and Linux tty ports through a PC’s USB port. The
UPort 1100 series includes the following models:
UPort 1110: 1-port RS-232 USB-to-Serial Converter.
UPort 1130: 1-port RS-422/485 USB-to-Serial Converter.
UPort 1130I: 1-port RS-422/485 USB-to-Serial Converter with Isolation
Protection.
UPort 1150: 1-port RS-232/422/485 USB-to-Serial Converter.
UPort 1150I: 1-port RS-232/422/485 USB-to-Serial Converter with
ATTENTION
Before plugging the adaptor into your computer’s USB port, we recommend
installing the driver first. Please refer to “Software Introduction” for
driver installation procedures. After the driver is installed, the adaptor can
be plugged into any upstream type A USB port, either on a PC host or on an
upstream hub. The adaptor is hot-pluggable, so there is no need to power down
your computer prior to installation. The Found New Hardware wizard will
automatically locate the appropriate drivers, and various windows will appear
as the adaptor is being installed.
After the Found New Hardware wizard finishes installing the adaptor, the
Windows Device Manager may be used to modify the settings for the new COM
port. The new COM port will be listed under Ports (COM & LPT) and the new
adapters will be listed under Multi-port serial adapters. For more information
about port configuration, please refer to the UPort 1100 series user manual.
Package Checklist
Before installing the adaptor, please verify that the package contains the
following items:
- UPort 1100 series USB-to-Serial Converter
- Quick installation guide (printed)
- Warranty card
The UPort 1130/1130I/1150/1150I will also come with the following item:
Mini DB9F-to Terminal-Block Converter
NOTE : Please notify your sales representative if any of the above items
are missing or damaged.
Windows Driver Installation
The following instructions and screenshots are from a PC running Windows
32-bit, but the same instructions apply for a Windows 64-bit platform. If you
want to know which Windows OSs Moxa supports, please go to support center on
Moxa’s website to check the latest driver
http://www.moxa.com/support/, under Product Support.
1. Run the Setup program, click Next to start installing the driver.
2. Click on Next to install the driver in the indicated folder.
3. Click on Install to proceed with installation.
4. Then, click Finish to complete the driver installation.
Installing the Hardware
1. Case 1: The UPort Driver is Certified
If the UPort driver that you installed has been certified by Microsoft, the UPort and the UPort’s serial ports will be installed automatically when you plug the UPort into your computer’s USB port.
Case 2: The UPort Driver is NOT Certified
If the UPort driver that you installed has not been certified by Microsoft,
then plugging the driver into your computer’s USB port will activate the UPort
installation program. The first part of the installation procedure installs
the software for the UPort itself (the second part of the procedure installs
the serial ports).
Plug the adaptor into any upstream USB port (e.g., a USB port on your
computer). Windows are done with hardware installation at this point and may
continue on to port configuration. Windows will auto-detect the UPort cable
and show Found New Hardware in the System Tray. 2. The following window will
appear. Select No, not this item click Next. 3. Select Install the software
automatically (Recommended), and then click Next to proceed. 4. The next
window cautions you that this software has not passed Windows logo testing.
This is a standard warning, and Moxa has thoroughly tested the driver for safe
Windows operation. Please click Continue Anyways to proceed. Then, click
Finish to complete the driver installation.
5. Repeat Step2 to Step 4 until COM port is installed.
Serial Port Assignments
The UPort 1100 series uses male DB9 connectors. Pin assignments are shown in
the following diagram:
Male DB9
Note that the converter maps pin 1 on the DB9 connector to pin 2 on the
terminal block, and pin 2 on the DB9 connector to pin 1 on the terminal block.
Installing the macOS Driver
Supporting macOS 10.12 and later, follow the steps below to install driver
- Enter Recovery Mode
- Disable System Integrity Protection (SIP) by typing ‘csrutil disable’ in the terminal
- Return to Normal Mode
- Launch the UPort driver installer
- Enter Recovery Mode again
- Enable System Integrity Protection (SIP) by typing ‘csrutil enable’ in the terminal
- Return to Normal Mode
For detailed instructions, please refer to ‘readme.txt’ in the driver installation package.
Installing the Linux Driver Linux Kernel 2.4.x
Execute the following commands from the Linux prompt:tar -xvfz driv_linux2.4_uport1p_vx.x_build_yymmddhh.tgz
cd /mxu1100_24/driver
# make clean
# make install
# modprobe mxuport1100_24
NOTE yy = year, mm = month, dd = day, hh = hour
For All Other Kernels
Please refer to readme.txt that is included in the driver file for detailed
instructions. The driver file can be downloaded from Moxa’s website, under the
Product page.
# tar xvfz driv_linux_uport1p_v1.x_build_xx.tgz
# make clean; make install
# modprobe mxu11x0
Installing the Win CE 5.0/6.0 Driver
Moxa provides two installation procedures that can be used to install the
Windows CE 5.0/6.0 driver: by “CAB file” and with the “installation package.”
In this document, we only cover the CAB file installation. If you need to use
package to install the WinCE driver, please refer to the user’s manual.
Installation with a CAB File
Step 1 : Install Microsoft ActiveSync on the source PC. Before running
ActiveSync on the source PC, use an RS-232 null modem cable to connect the
WinCE device (CEPC) to the PC.
Step 2 : Go to the “Command Prompt” on the WinCE device and execute the
repllog command. A new partnership window will appear. Select “No” and then
click on “Next.” You will see “Connected” in ActiveSync.
Step 3 : Click on the “Explore” button in the ActiveSync window, and then
copy the
UP1100_COM_v1.0_Setup.CAB (For WinCE 6.0) or
UP1100_COM_v1.1_Setup.CAB (For WinCE 5.0)
file to the Mobile/Target Device.
Step 4 : Double click on the CAB file to start installing the UPort 1100
series WinCE driver.
After installing the driver, plug the UPort 1100 series device into the USB
port of the WinCE Device. The driver will be loaded automatically. At this
point, the UPort 1100 series is ready to use.