etiampro LQC3B-V1 Multi-Channel LED Dimmer Instruction Manual

June 6, 2024
etiampro

etiampro LQC3B-V1 Multi-Channel LED Dimmer

FEATURES

  • SEQUENCER+FADER+DIMMER+DRIVER
  • DC Input 12-24-48 Vdc
  • Command: N.O. push button
  • Tunable white control or RGB color control
  • Current outputs or voltage outputs for LED strip
  • Typical efficiency > 95%
  • Adjusting the brightness up to completed off
  • Soft start and stop
  • Optimized output curve
  • Extended temperature range
  • 100% Functional test – 5 Years warranty

Constant voltage variants (common anode)

  • application (2-channels output): tunable white
  • Application (3-channels output): RGB color

CODE| Supply voltage| Output| Channels| Command|
---|---|---|---|---|---
LQC3B-V1| 12÷48V DC| 3 x 1,6A max.| 3| N.O. push button|

Protections

  • OTP            Over temperature protection
  • OVP            Over voltage protection
  • UVP            Under voltage protection
  • RVP          Reverse polarity protection
  • IFP            Input fuse protection
  • SCP          Short circuit protection
  • OCP          Open circuit protection
  • CLP            Current limit protection

Reference standards

  • EN 61347-1:2008+A1:2011+A2:2013 Lamp controlgear – Part 1: General and safety requirements
  • EN 61000-3-2:2014 Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
  • EN 61000-3-3:2013 Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
  • EN 62384:2006+A1:2009 DC or AC supplied electronic control gear for LED modules – Performance requirements
  • EN 55015:2013+A1:2015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
  • EN 61547:2009 Equipment for general lighting purposes – EMC immunity requirements
  • EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances

Technical Specifications

  Variants

Constant voltage
3 channels
Supply voltage| DC min: 10.8 Vdc .. max: 52,8 Vdc
Input current1)| max 4,8A
Output voltage| = Vin
Output current1)| Max 1.6 A/ch 1)
max 4,8A
Nominal power 1)| @12V| 57,6Wmax
@24V| 115,2 Wmax
@48V| 230,4 Wmax
Thermal shutdown| 150 °C
D-PWM dimming frequency| 250Hz
D-PWM resolution| 16 bit
D-PWM range| 0,1 – 100 %
Storage Temperature| min: -40 max: +60 °C
Ambient Temperature 1)| min: -10 max: +40 °C
Protection grade| IP20
Wiring| 2.5mm² solid – 1.5mm² stranded – 30/12 AWG
Mechanical dimensions| 44 x 44 x 25 mm
Packaging dimensions| 68 x 56 x 35 mm
Weight| 40g

Installation

etiampro-LQC3B-V1-Multi-Channel-LED-Dimmer-
fig1

Connect the switching supply, connect the N.O. push button, connect leds.

Function

The outputs status is memorized and reloaded in the case of supply interruptions.

RGB COLOUR
RGB colours are managed by a N.O. push button in the following variants:

Key| Function|
---|---|---
 |  | Click

Long pressure (>1s) from OFF Long pressure (>1s) from ON

| ON/OFF

Change rotation speed* Start/stop color rotation

*Color rotation speed is selectable from 4 predefined levels. The selected speed is visualized with a white strobe output:

  • 10 flash/s for the rotation of 6 seconds
  • 5 flash/s for the rotation of 30 seconds
  • 2 flash/s for the rotation of 6 minutes
  • 1 flash/s for the rotation of 30 minutes

Technical Notes

Installation:

  • Installation and maintenance must be performed only by qualified personnel in compliance with current regulations.
  • The product must be installed inside an electrical panel protected against overvoltages.
  • The product must be installed in a vertical or horizontal position with the cover / label upwards or vertically; Other positions are not permitted. It is not permitted to bottom-up position (with the cover / label updown).
  • Keep separated the circuits at 230V (LV) and the circuits not SELV from circuits to low voltage (SELV) and from any connection with this product. It is absolutely forbidden to connect, for any reason whatsoever, directly or indirectly, the 230V mains voltage to the bus or to other parts of the circuit.

Power Supply:

  • For the power supply use only a SELV power supplies with limited current, short circuit protection and the power must be dimensioned correctly. In case of using power supply with ground terminals, all points of the protective earth (PE = Protection Earth) must be connected to a valid and certified protection earth.
  • The connection cables between the power source “low voltage” and the product must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Use double insulated cables.
  • Dimension the power supply for the load connected to the device. If the power supply is oversized compared with the maximum absorbed current, insert a protection against over-current between the power supply and the device.
  • For the constant current output, the voltage of the LED module (Vf) must be less of 5V at the voltage of power supply.

Command:

  • The length of the connection cables between the local commands (N.O. Push button or other) and the product must be less than 10m; the cables must be dimensioned correctly and they should be isolated from every wiring or parts at a voltage not SELV. Use double insulated shielded and twisted cables.
  • All the product and the control signal connect at the local command (N.O. Push Button or other) must be SELV (the devices connected must be SELV or supply a SELV signal)

Outputs:

  • The length of the connection cables between the product and the LED module must be less than 10m; the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Is preferable to use shielded and twisted cables.

Read User Manual Online (PDF format)