UVC PURELIGHT 360 PL-UVC360-1 Smart UVC Sanitization System User Manual
- June 6, 2024
- UVC PURELIGHT 360
Table of Contents
UVC PURELIGHT 360 PL-UVC360-1 Smart UVC Sanitization System
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- This equipment is designed for using with germicidal UV radiation sources. UV radiation can cause a risk of personal injury. Overexposure can result in damage to eyes and bare skin. To reduce the risk of overexposure, this equipment must be operated by a professional person.
- Maintenance and servicing of this UV equipment shall be operated by a professional person. An operating person must wear appropriate Personal Protective Equipment (PPE). If the equipment needs to be in operation during the maintenance or servicing work, pls contact the equipment manufacturer for PPE recommendations and guidance.
- Do not use this equipment for other purpose.
- If using an accessory, which is not recommended by the manufacturer, to the equipment, it may cause unsafe condition.
- People, pets, and plants should be away from the sterilizing area when using the equipment.
- The equipment should be stored well to avoid any potential accidental damage after used.
Warning: Don’t look at the disinfection light directly. People, pets and plants should be away from the sterilizing area when using the disinfection cart. Ventilate for 30-40 minutes for sterilized area after working.
TECHNICAL SPECIFICATIONS
Fixture power | 320W | Ambient temperature | 0~+40℃ |
---|---|---|---|
UV lamp power | 300W | Storage temperature | -10~+60℃ |
Input voltage | 120-277Vac | Time shutdown | 0~20min |
Peak wavelength | 253.7nm | Power factor | >0.9 |
Beam angle | 360° | Weight | 28.5kg |
--- | --- | --- | --- |
Life | 60000Hrs | IP level | IP20 |
UV radiation intensity(1m) | 1300uW/cm² | Color | Black |
Safety classification | Class Ⅰ | Dimensions(LWH)(mm | L940W500H1540mm |
manual operation
-
Plug in the cart and turn on power switch . Rotate the rotary dial to choose sanitizing cycle 5min、10min、20min (default
option is OFF). 90S countdown is started and shown on display. At the end of 90S, chime sound warns users leave sanitizing area (three,Di Di Di) -
During the 90S countdown, PIR sensor doesn’t active. After 90s end, the cart enter sanitizing cycle, at the meantime, PIR sensor starts to work. When PIR sensor detected someone is still in the sanitizing area, UVC lamp will turn off automatically. When motion is no longer detected, UVC lamp will not turn on to proceed work automatically. If users want to restart the cart, they need to turn off the power switch then turn on the power switch to restart it manually;
-
IF the cart with WIFI,Plug in the cart and turn on power switch . Press pairing button 5S till blue pairing indicator light flash quickly,after successful connection, the indicator light will always be on . Open phone and enter APP UI, users can set the time. When PIR sensor detected motion during sanitizing cycle, UVC lamp will turn off automatically. When motion is no longer detected, UVC lamp will not turn on to proceed work automatically. Users need to click on/off button on APP if they want to restart the cart( there is no 90S countdown). When users don’t know whose phone connected to the device,Long press the press pairing button to remove the device
Motion Sensor Operation(If the lamp with Motion Sensor)
- Turn on the UV lamp, select the disinfection time and left the room, after 90 seconds, alarming(Di….Di…Di….), the UV lamps will switch on automatically, the motion sensor will activated.
- It will turn off when it detects that someone moving around . If users want to restart the cart, they need to turn off the power switch then turn on the power switch to restart it manually
Note:
- The surface of the lamp should be kept clean.
- The lamp is fragile. Please handle it with care.
- A room should be ventilated after UV disinfection, and people are suggested to enter the room 30-40minutes later.
Warning
FCC Warning
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any inte rference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interferenceto radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>