DAIKIN DV1-15-2117-AB Premium Air Cleaner for Air Handler Instruction Manual

June 6, 2024
Daikin

DV1-15-2117-AB Premium Air Cleaner for Air Handler
Instruction Manual

Air Cleaner Model # Furnaces DV1-15-2824-FD
DV1-15-2814-FA DV1-15-2117-AB
DV1-15-2817-FB DV1-15-2121-AC
DV1-15-2821-FC DV1-15-2124-AD
DV1-15-2824-FD DV1-15-2124-AD

MODELS
DV1-15-2117-AB
DV1-15-2121-AC
DV1-15-2124-AD
DV1-15-2814-FA
DV1-15-2817-FB
DV1-15-2821-FC
DV1-15-2824-FD

Specifications

Description

The Daikin One Premium Air Cleaner is an in-line air cleaner that treats home air for airborne particulate matter and chemicals found in the home. The high- efficiency MERV 15 media filter removes more than 85% of particles down to 0.3 microns in size at rated flow. The Daikin One Premium Air Cleaner also includes a room temperature catalyst (RTC) insert that helps remove formaldehyde and ozone from the air stream.
Proprietary Notice
This document and the information disclosed herein are proprietary data of Daikin North America LLC. Neither this document nor the information contained herein shall be reproduced, used, or disclosed to others without the written authorization of Daikin North America LLC, except to the extent required for installation or maintenance of the recipient’s equipment.
Copyright Notice
Copyright 2022, Daikin North America LLC All rights reserved.
Replacement Filters

Air Cleaner Model (1)| Replacement MERV15 Filter (2)| Replacement Room Temperature Catalyst (RTC)
---|---|---
DV1-15-2117-AB| 0160M00013| DVFC-AB
DV1-15-2117-FC| 0160M00014| DVFC-AC
DV1-15-2117-FD| 0160M00015| DVFC-AD
DV1-15-2117-FA| 0160M00016| DVFC-FA
DV1-15-2117-FB| 0160M00017| DVFC-FB
DV1-15-2117-FC| 0160M00018| DVFC-FC
DV1-15-2117-FD| 0160M00019| DVFC-FD

The filter should be changed once or twice a year based on conditions within the home. RTC should be changed once every six months based on conditions within the home. (1)EPA EST. NO. 073316-TEX-001 · (2)EPA EST. NO. 71027-MEX-001

Read and save these instructions.

WARNING!
This symbol indicates important instructions. Failure to heed them can result in serious injury or death.
CAUTION!
This symbol indicates important instructions. Failure to heed them can result in injury or material property damage.
WARNING!
Before beginning any installation or modification, be certain that the mainline electrical disconnect switch is in the OFF position. Unexpected start-up of system blower may cause serious injury. Tag disconnect switch with suitable warning labels.
CAUTION!
Installation:

  • Only trained personnel should install this unit (see a warning on cover page).
  • Homeowners can perform the basic maintenance functions of replacing filters.
    See Handling, Storage, and Disposal of Replacement Filters

WARNING!
Risk of Carbon Monoxide. Do not use this air cleaner without the cabinet door installed. If the cabinet ddoor is not installed, there is a risk that exhaust fumes may be drawn into occupied spaces, which can cause injury or death.
WARNING! This air cleaner utilizes very strong magnets to fasten the cabinet door. Magnets may interfere with pacemakers and Implantable Cardiac Defibrillators (ICDs).
WARNING! Do not ingest magnets; ingested magnets can cause serious intestinal injury.
CAUTION! This air cleaner utilizes industrial strength magnets. Hold front door panel with both hands when removing or replacing door to avoid pinching fingers between door and cabinet.

Handling, Storage, and Disposal of Replacement Filters.
Storage of Replacement Room Temperature Catalyst Insert
When working on the air cleaner, observe precautions in the Owner’s Manual labels attached to the furnace or air handler, and other safety precautions that may apply. · Always use personal protective equipment that is clean and has been properly maintained.

  • Always use safety glasses

  • Always use work gloves that is resistant to chemical agents
    – Recommended Natural latex.

  • Always use a disposable half-mask dust filter.

  • Avoid contact with eyes.

  • Avoid skin contact.

  • Avoid breathing dust.

  • Never eat, drink or smoke in the area where you are replacing the filters.

  • Always wash hands and face thoroughly after handling.

CAUTION! Potassium iodide exposure may cause skin irritation, serious eye irritation and damage to organs through prolonged or repeated exposure (if swallowed). Do not breathe dust/fume/ gas/mist/vapours/spray.

  • If on the skin; Remove contaminated clothing and wash the skin thoroughly with water – If the contaminated area is widespread and/or there is damage to the skin, seek medical attention.
  • If in the eyes; Rinse thoroughly with fresh, clean water holding the eyelids open. Remove contacts lenses, if present and easy to do. Continue rinsing.
  • If there is any redness, pain, or visual impairment, consult an ophthalmologist.
  • In an event of swallowing, seek medical attention immediately. Do NOT give the patient anything orally. If the swallowed quantity is small (no more than one mouthful), rinse the mouth with water and consult a doctor.

Important: Read and save these instructions. This guide is to be left with the equipment owner.

Storage of Replacement Room Temperature Catalyst Insert and MERV 15 filter

  • Keep away from any chemicals (solvents and strong oxidizers).
  • Keep away from heat sources.
  • Prevent dust generation
  • Store in a well-ventilated area.
  • Keep the package tightly closed and away from dampness and humidity.

Disposal of Replacement Room Temperature Catalyst Insert and MERV 15 filter

  • Dispose of in accordance with national, state and local regulations. Disposal requirements are dependent on the hazard classification and will vary by location and the type of disposal selected.
  • Do not contaminate the ground or water with waste; do not dispose of waste into the environment.

Installation

IMPORTANT: This air cleaner may cause more of a restriction on the airflow in the air-handling system than a standard 1″ equipment filter, because of its increased efficiency. As the filter collects particulates, the pressure drop increases, and airflow through the filter decreases. This air cleaner is not recommended where added pressure drop would cause operational problems with the heating and cooling equipment.
Location
This air cleaner is adaptable to unitary residential forced-air heating or cooling systems. It is designed to be installed in the return air duct close to the blower compartment of the furnace or air handler. This location provides the evenest air flow across the filter helping to keep the system motor and fan clean.
To improve the performance of the air cleaner, these simple steps are recommended:

  • Run your heating/cooling system fan continuously, on low speed if available, since the air cleaner only removes particulate matter when the system fan is operating.
  • Ensure there are no obstructions to airflow (for example, from furniture or carpets) in front of the return air grilles so that air moves freely to the heating/cooling equipment.

WARNING! Turn off the heating and cooling system fan before performing maintenance to the air cleaner.

Dimensions (in)

MODEL A B1 B2 C D E F G
DV1-15-2117-AB 17.5 21.1 22.7 1.4 0.8 1.3 14.7 19.4
DV1-15-2121-AC 21.0 21.1 22.7 1.4 0.8 1.3 18.2 19.4
DV1-15-2124-AD 24.5 21.7 22.7 1.4 0.8 1.3 21.7 19.4
DV1-15-2814-FA 14.0 28.0 28.6 0.8 0.8 3.8 12.5 23.9
DV1-15-2817-FB 17.5 28.0 28.6 0.8 0.8 3.8 16.0 23.9
DV1-15-2821-FC 21.0 28.0 28.6 0.8 0.8 3.8 19.5 23.9
DV1-15-2824-FD 24.5 28.0 28.6 0.8 0.8 3.8 23.0 23.9

General Installation Steps

  1. Remove existing equipment filter (if present) and clean blower compartment: Thoroughly clean the blower compartment, since the air cleaner cannot remove accumulated dirt from the blower chamber and distribution ducts.

  2. Leave sufficient room around the air cleaner: There must be adequate room to remove and replace the filter from the air cleaner cabinet.

  3. Transitions: If the air duct does not fit the air cleaner opening, a gradual transition is recommended to reduce air turbulence through the air cleaner and ensure its efficient operation. A maximum of 20° of expansion, or approximately 4 inches per running foot (10 cm per 30 cm), is recommended for each side of the transition fitting. Note: Do not reduce ductwork size to fit a smaller air cleaner. This will increase the velocity of airflow and may decrease cleaning efficiency.

  4. Turning vanes: If the air cleaner is installed adjacent to an elbow or angle fitting, field-installed turning vanes are recommended to improve air distribution across the filter.

  5. Remove the door: When removing or replacing the door, hold the outer door panel with both hands. The door has industrial strength magnets in it which can pinch fingers if caught between door and cabinet.

  6. Remove filters: remove filters (MERV 15 & RTC) from cabinet

  7. Install the cabinet: Attach cabinet to furnace and filter riser, air handler or Furnace plenum with the ten self-tapping hex head screws provided. Note the direction of flow indicated on the top and bottom of the cabinet.

  8. Seal the joints in the return air system: All joints and seams between the air cleaner, the heating/cooling equipment, and the return air duct should be sealed with aluminum tape or mastic to prevent dust from entering the clean air stream.

  9. Replace filters and door: After attaching the cabinet and sealing all joints, reinstall filters (note the direction of flow). Reinstall the door, making sure it is properly seated. Remove the plastic bag before installing the room temperature catalyst (RTC) insert.

  10. Adjust Daikin Badge: If a different orientation is needed, slide the badge up and pull it out of the door. Rotate to proper orientation and reinstall.

Specifications

MODEL| DV1-15-2117-AB| DV1-15-2121-AC| DV1-15-2124-AD| DV1-15-2814-FA| DV1-15-2817-FB| DV1-15-2821-FC| DV1-15-2824-FD
---|---|---|---|---|---|---|---
Airflow – up to
maximum rated flow| Up to 1200 cfm
(2039 m3/h)| Up to 1600 cfm
(2718 m3/h)| Up to 1800 cfm
(3058 m3/h)| Up to 1200 cfm
(2039 m3/h)| Up to 1600 cfm
(2718 m3/h)| Up to 2000 cfm
(3398 m3/h)| Up to 2000 cfm
(3398 m3/h)
Duct Size| 21 x 17 in
(53 x 43 cm)| 21 x 21 in
(53 x 53 cm)| 21 x 24 in
(53 x 61 cm)| 28 x 14 in
(71 x 36 cm)| 28 x 17 in
(71 x 43 cm)| 28 x 21 in
(71 x 53 cm)| 28 x 24 in
(71 x 61 cm)
Pressure Drop
(Filters Only)| 0.11 in. w.g.
@ 600 cfm| 0.11 in. w.g.
@ 800 cfm| 0.11 in. w.g.
@ 900 cfm| 0.10 in. w.g.
@ 600 cfm| 0.10 in. w.g.
@ 800 cfm| 0.10 in. w.g.
@ 1000 cfm| 0.08 in. w.g.
@ 1000 cfm
0.26 in. w.g.
@ 1200 cfm| 0.31 in. w.g.
@ 1600 cfm| 0.27 in. w.g.
@ 1800 cfm| 0.27 in. w.g.
@ 1200 cfm| 0.26 in. w.g.
@ 1600 cfm| 0.24 in. w.g.
@ 2000 cfm| 0.19 in. w.g.
@ 2000 cfm
MERV Rating
| 15| 15| 15| 15| 15| 15| 15

Notes:

  1. Installation with units with ECM motors is recommended.
  2. Two filters should be considered for any airflow rates above maximum rated flow or when duct pressure loss is excessive.
Furnace Size A B C D
Furnace Riser AMP-BSRB-1428 AMP-BSRB-1728 AMP-BSRB-2128 AMP-BSRB-2428

When using a furnace riser use DV1-15-2824-FD on all size furnaces
MERV Rating 15 – Minimum Filtration Efficiency @492 fpm:

  • E1 85% (0.3 – 1.0 micron)
  • E2 90% (1.0 – 3.0 micron)
  • E3 95% (3.0 – 10.0 micron)

*Independent testing performed by LMS Technologies, Inc. Specification values may vary due to individual systems.
Filter Match-up Options

Air Handler Filter Options

Air Handler Size| Bottom/Top Return| Plenum Return
B| 21×17| 21×21
C| 21×21| 21×24
D| 21×24| 21×24
| Furnace Filter Options
---|---
Furnace Size| Bottom/Top Return| Side Return| Side Return with Furnace Riser
A| 28×14| 28×17| 28×24
B| 28×17| 28×17| 28×24
C| 28×21| (2) 28×17| 28×24
D| 28×24| (2) 28×17| 28×24

Duct transition for side flow dual filter installation furnace/air handler application

Dual filter furnace application, side return (For any side return on a furnace without a furnace riser, use one DV1-15-2817-FB on A & B or two DV1-15-2817-FB on C & D furnace sizes)

Single filter furnace application, side return with furnace riser (When using a furnace riser, use DV1-15-2824-FD on all furnace sizes)

NOTE: Not all installation options are included below.

Daikin North America LLC reserves the right to discontinue or change at any time, specifications or designs without notice or without incurring obligations. The performance of the Air Cleaners will depend on house plan design, duct design, and heating/cooling equipment.
Our continuing commitment to quality products may mean a change in specifications without notice.
Houston, Texas
Printed in the USA

WARNING

Only personnel that have been trained to install, adjust, service or repair (hereinafter, “service”) the equipment specified in this manual should service the equipment. Daikin will not be responsible for any injury or property damage arising from improper service or service procedures. If you service this unit, you assume responsibility for any injury or property damage which may result. In addition, in jurisdictions that require one or more licenses to service the equipment specified in this manual, only licensed personnel should service the equipment. Improper installation, adjustment, servicing or repair of the equipment specified in this manual, or attempting to install, adjust, service or repair the equipment specified in this manual without proper training may result in product damage, property damage, personal injury or death.
PROP 65 WARNING FOR CALIFORNIA CONSUMERS
WARNING
Cancer and Reproductive Harm www.P65Warnings.ca.gov * Complete warranty details available from your local dealer or online at www.daikincomfort.com.
To receive the 12-Year Unit Replacement Limited Warranty or the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registrations is not required in California or Quebec.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Daikin User Manuals

Related Manuals