FITCENT CL806 Heart Rate Monitor Chest Strap User Manual
- June 5, 2024
- FITCENT
Table of Contents
FITCENT
HEART RATE MONITOR
CHEST STRAP
USER MANUAL
Model: CL806
Thank you for purchasing this product as your sports fitness product of
choice. The product is a sensor-type heart rate monitor that will track your
real-time heart rate and send heart rate data to the Smart phone.
IMPORTANT This product is for sport purposes only and it is not meant
to replace any medical advice.
This manual contains important safety and care information and provides step-
by-step instructions for using this product. Read it thoroughly, and keep the
manual in a safe place in case you need to refer to it later.
DEVICE OVERVIEW:
A. Heart rate Transmitter
a. Front View
The device flashes green for 5 times when it is turned on, The green lights turns on for 3 seconds when device turns off.
-
Battery Door
-
Left & Right wearing directions
B. Heat rate chest strap -
Electrodes
-
Fastening buttons
GETTING STARTED
A. Unpacking the product In this box, you will find:
a. Heart rate transmitter
b. Adjustable elastic strap
c. CR2032 battery- already installed
d. User manual
B. To wear chest strap
a) Wet the conductive pads on the rear of the chest strap with a few drops of
water, Saliva or conductive gel to ensure solid contact.
b) Strap the heart rate chest belt across your chest. To ensure an accurate
heart rate signal, adjust the strap until the belt fits snugly below your
(chest) pectoral muscles.
c) Attach the transmitter to the strap, marked I’ towards left.
C. APP PAIRING
a. Turn on BLUETHOOTH| b. Download the APP| c. Activate the Sensor| d. Pair
Sensor Open the APP to the sensor page
e. Start your workout
---|---|---|---
WARNING
a.Cleaning of transmitter and strap in a washing machine or dryer is strongly
prohibited.
b.Before hand washing the device, detach the transmitter of Heart Rate Monitor
where electrodes are located, This part is not washable.
c.While washing the straps, make sure water is no higher than 30°C.
d.Ironing, bleaching or heating is prohibited.
IMPORTANT
- Non-rechargeable and rechargeable batteries must be disposed of properly. For this purpose, special containers are provided for battery disposal at communal collection centers.
- Batteries are extremely dangerous when swallowed! Therefore, keep batteries and small articales away from children.
- The batteries supplied must not be recharged, reactivated by any other means, dismantled, put into fire or short-circuited
DATE TRANSMISSION
ANT+ & BLE Sports System is supported to achieve reliable data transmission by
this HRM.
For ANT+ System:
A. Pairing
If the HRM is not paired with the ANT+ compatible receiver, it has to be
activated and paired.
– Ensure that the HRM battery is not drained. Replace the battery if needed.
– Ensure there are no other ANT+ transmitting devices within 50 m range, other
devices may affect pairing.
B. Ready to use
If your device is successfully paired, it’s ready for use.
Compatible Apps:
Wahoo Fitness, Polar Beat, Zwift, Runtastic Pro, Nike+ Run Club
-
All brand names and trademarks are properties of their respective owners.
Disclaimer- The information contained in this manual just for reference. The product described above may be subject to alteration owing to the manufacturer’s continuing research and development plans, without making an announcement in advance.
- and expenses arising from or in connection with this manual or the contained product. We shall not bare any legal responsibility for any direct or indirect, accidental or special damages, losses
CE and FCC statement
Hereby, We, declares that heart rate monitor, Chest, strap (CL806) is in
compliance with the essential requirements and other relevant provisions of
Directive RED 2014/53/EU. A copy of the signed and dated Declaration of
Conformity is available.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must
accept any interference received, including interference that may cause
undesired operation.
WARNING: Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio / TV technician for help.
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.