QZ2142-840 60Hz Smart Plug Dimmer
User Manual
Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may caus harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution: This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
SPECIFICATIONS
- Model:QZ2142-840
- Power: 120 VAC, 60 Hz.
- Signal (Frequency): 908.42 MHZ.
- Maximum load for outlet 500W Resistive
- Maximum load for the Z-Wave™ controlled outlet
- Range: Up to 100 feet line of sight between the Wireless Controller and the closest Z-Wave™ receiver module.
- Operating Temperature Range: 32-104° F (0-40° C)
Specifications subject to change without notice due to continuing product
improvement
Website:dealers.qolsys.com
WARNING
-
RISK OF FIRE
-
RISK OF ELECTRICAL SHOCK
-
RISK OF BURNS
-
CONTROLLING APPLIANCES:
-
EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL
-
APPLIANCES. OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A DIFFERENT
-
ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION
-
MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES
-
MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
-
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL
-
OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
-
REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING: -
DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC
-
HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
-
A HAZARDOUS CONDITION DUE TO UNATTENDED OR
-
UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
Introduction:
This product can be operated in any Z-Wave network with other Z-Wave Plus™ certified devices from other manufacturers.
All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Each module is designed to act as a repeater, which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
QZ2142-840 is a security enabled Z-Wave Plus™ device. A security Enabled
Z-Wave Plus™ Controller must be used in order to fully utilize the product.
The Device Type of the QZ2142-840 is on/off power switch.
The Role Type of the QZ2142-840 is Always On Slave Role Type
Key Features:
- Remote ON/OFF control via the Z-Wave™ controller
- Manual ON/OFF control with the front panel push button
- Support Association Group and Auto Report switch status
- Support firmware upgrades via Over-the-air (need Gateways support)
- Support Scenes
Product Overview:
- A – AC plug
- B – Z-Wave controlled outlet
- C – ON/OFF/PROG Push button/ Status LED
Key function description
Function 1: Press the button to turn the output ON or OFF
Function 2: quickly press 3x Button: ADD(inclusion) (only if switch is not included in network)quickly press 3x Button: Remove( exclusion)
Function 3: Press click Z-Wave button 3 times quickly, and hold for at least 10 seconds at the third time to restore the device to the factory ( Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable.)
Function 4: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Adding Your Device To A Hub
The device support two methods of inclusion, When using a Z-Wave Plus™ certified controller choose Network Wide Inclusion or SmartStart, Network Wide Inclusion To A Z-Wave™ Network
- Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
- When prompted by your primary controller, click the button three times in one second.
The device is compatible with SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the
Z-Wave™ QR Code found on the top of the outlet or the back of the box with a
controller providing SmartStart inclusion. No further action is required and
the SmartStart product will be added automatically within 10 minutes of being
switched on and in the network vicinity.
QR CODE
The QR code is found to the side of the case, DSK is included in the QR code.
DSK
The DSK code can be found on the DSK label which is attached on the packaging box.
Command Class
Z-Wave™ Configuration Parameters
You may use the below configuration parameters to change settings of the corresponding functionality.
Support for Association Groups
QZ2142-840 supports 3 association groups. Group 1 supports 1 node ID,Group 2
and Group 3 Supports maximum of 5 node ID’s
Association group_1:Z-Wave™ Plus Lifeline
Association group_1 is default to associate with the primary controller
(Gateway/Hub/Controller) for QZ2142-840 Status change report,
1. QZ2142-840 will trigger AUTO report function if the Switch status had been
changed.
(ex.Switch Multilevel Report/Indicator Report/Central Scene Notification/
Device Reset Locally Notification)
Association group_2:basic set command on/off control
When the output of the QZ2142-840 is changed, On (0xFF) or Off (0x00). The
QZ2142-840 will automatically send out a related basic set command. On (0xFF)
or Off (0x00) to its associated group.
Association group_3:basic set command on/off control
When the output of the QZ2142-840 is changed, On (0xFF) or Off (0x00). The QZ2142-840 will automatically send out a related basic set command. On (0xFF) or Off (0x00) to its associated group
Basic Command Class
The basic command class is mapped to the SWITCH MULTILEVEL command class
Restoring Factory Defaults
QZ2142-840 is removed from the network and will be restored to the factory
setting
All Configuration Parameters values and Association information will be
restored to factory default settings and excluded from the network.
Manual Reset: Press click Z-Wave button 3 times quickly, and hold for at least 10 seconds at the third time to restore the device to the factory
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Association Groups
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>