PORTABLE AIR SCRUBBER
MODEL: HSC-HEPA2000
USER’S MANUAL
-
Keep this manual on hand for reference.
-
This unit is specified for use on the rated voltage power supply. For use outside the local electricity supply should be checked by a qualified electrician.
-
Thank you for purchasing the unit.
Before operation please read this user’s manual carefully. -
It is essential that you read ‘SAFETY INSTRUCTIONS’ carefully before use and follow them at all times.
-
The warranty form is on the last page. Please complete it now and keep it in a safe place.
-
We have a policy of continual improvement on our products.
The contents (features and specifications) in this manual are therefore subject to change without notice.
SAFETY INSTRUCTIONS
The following instructions are for ensuring the user’s safety and preventing any physical injury or material damage. Please read carefully and follow all instructions.
WARNING AND CAUTION
-
Insert the power plug into the outlet for 115Vac 60Hz 1Ph only.
-
When inserting the power cord into the outlet, turn off the switch before use.
-
Do not touch the product with a wet hand.
-
Do not put anything heavy on the power cord.
-
When water gets into the product or the electricity part, pull out the power plug and dry it completely before use.
-
Unplug the unit when during heavy lightning or electrical storms.
-
Do not put the product in a humid place.
It may occur a danger such as an electric leak or electric shock. -
Do not install it at the place where inflammable gas is generated.
It may occur a danger of explosion. -
Remove any obstacle at the inhaling hole and the exhaling hole.
-
When cleaning the surface of the product, pull the power cord out, and use a soft cloth for preventing a scratch.
-
Do not use wet cloth, wax, or thinner.
-
Do not put a hand or foreign substance into the inhaling hole or the exhaling hole.
It may occur as a malfunction of the product or a physical injury. -
Pertaining to a risk of fire, electric shock, or injury to persons, for cleaning and user maintenance, such as lubrication.
-
Warn the user to unplug or disconnect the appliance from the power supply before servicing.
※ Keep this manual in a visible location near the unit for easy access.
EXTERIOR DESCRIPTION
CONTROL PANEL FUNCTIONS
① Pressure Gauge
② Pressure Sensing Port
③ Circuit Breaker
④ Fan Speed (High / Off / Low) Switch
- Before connecting the power cord, confirm the switch is turned off without fail.
- For starting the product, press the switch in the control panel to the low or high.
- For stopping the operation, press the OFF.
WIRING DIAGRAM
SPECIFICATIONS
MODEL | HSC-HEPA2000 |
---|---|
Power Supply | 115Vac 60Hz 1Ph |
Power Consumption | High : 1,25kW / Low : 1,06kW |
Air Flow | High : 1,950 CFM / Low : 1,410 CFM |
Dimension (WxDxH) | 28.5 x 30 x 30 inch |
Weight | 132 lbs |
FILTER
Do not operate without the HEPA filter installed! Operating without the HEPA
filter or using non-approved power cords may cause damage to the electrical
system or mechanical components. Failure to comply will void all warranties.
■ TIME OF FILTER CHANGE
- At the time the pressure gauge value is 0.72 in high, and more than 0.62 in low.
- At the time the filter is damaged due to a long-time use.
- At the time the inhaling power falls due to a clogging in the filter.
Time of filter change
TROUBLESHOOTING
TROUBLE | CHECK & REMEDY |
---|---|
The machine cannot be operated | Confirm that the power cord is correctly |
connected to the outlet.
After operating, the power turns off.| Due to an over-electric current, the
power source is being cut.
Please check the circuit breaker.
Inhaling/exhaling is weak.| Check if the filter is damaged or contaminated.
Dust is flowed out of the exhaling hole.| Check if the filter is damaged or
correctly installed.
WARRANTY
(Applicable to first retail purchaser only)
AIRTEX unit gives the more reliable performance, comfort and durability the
more they are used. They are built under a strict quality assurance regime
which includes inspection both during and after production and exhaustive
reliability testing.
In the unlikely event you have any problems, please contact your dealer or distributor. If the problem is as a result of a production fault or failure, repairs will be undertaken free of charge during the period of warranty subject to the following warranty conditions:
- If the problem has been caused by customer error or misuse, abuse, or damage, then all repairs will be charged for.
- This warranty applies to your country.
- Proof and date of purchase must be supplied.
- Please complete the details below and keep this warranty in a safe place.
- All transportation charges back to the dealer are at the customer’s cost. Keep all original packaging to facilitate the return. Return to a customer will be at dealer’s cost (if genuine warranty claim).
DESCRIPTION | PORTABLE AIR SCRUBBER |
---|---|
MODEL | HSC-HEPA2000 |
DATE OF PURCHASE | |
SERIAL NO. | |
WARRANTY PERIOD |
( ) Months
---|---
DISTRIBUTOR| Name of Company|
Telephone No.|
CUSTOMER DETAILS| Name :
---|---
Address :
Telephone :
Manufactured by :
HEPHZIBAH CO., LTD.
(Juan-dong) 86, Gilpa-ro
71beon-gil, Michuhol-gu,
Incheon, Korea
TEL : +82-32-509-5834
FAX : +82-32-502-5519
E-mail : airrex@hdtek.com
Website : www.airrex.biz| Distributed by :
Airrex USA
1191 Jewell Dr Ste 101 Waco, TX 76712TEL :
888-535-8841
FAX : 469-574-7924
E-mail : sales@airrexusa.com
Website : www.airrexusa.com
---|---
● Designs and specifications of products are subject to change without prior notice for the improvement of products.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>