Haste MFE Ceiling Unit Cooler Commercial Range Instructions

June 3, 2024
Haste

Haste MFE Ceiling Unit Cooler Commercial Range

CASING

Recyclable ABS casing, guaranteeing:

  • High resistance to thermal and mechanical shocks.
  • Perfect hygiene as a result of the rounded corners that eliminate retention zones.
  • No sharp edges for increased safety.

OPTION EMA

Wall kit available on MF1 and MF2

MF

  • (1) Heavy duty cabinet.
  • (2) Standard cold room

Haste-MFE-Ceiling-Unit-Cooler-Commercial-Range-fig 3

Example: Heavy duty cabinet – Volume: 1,100 dm³ – temperature +2 °C Selection: MF 3 (and 3/8 HP compressor).

VENTILATION

  • 4-pole motor(s), polypropylene blade.
  • Corrosion resistant blade and grille.

COILS

  • Aluminium fins with 4.23 mm spacing and sinusoidal profile. Combined with copper tubes with a grooved internal structure, the coils are very efficient and compact.
  • Completely covered with polyester protection as standard.
  • Low refrigerant volume.

Haste-MFE-Ceiling-Unit-Cooler-Commercial-Range-fig 9

Haste-MFE-Ceiling-Unit-Cooler-Commercial-Range-fig 6

  • (1) Heavy duty cabinet.
  • (2) Standard cold room

MF(A) 1(B)

  • (A) MF = positive temperature without defrost MFE = negative temperature with defrost
  • (B) Number of fans
CONDITIONS  REFRIGERANT MF 1 2 3 4
SC2 (1)             R449A W 300 380 740

790
| | | | |
CONDITIONS  REFRIGERANT| MFE | 1| 2| 3| 4
SC3 (1)             R449A| W| 220| 270| 520| 600
SC4 (1)            R449A| W| 140| 200| 380| 400
| W| 140| 160| 330| 330
| A| 0.64| 0.73| 1.5| 1.5
| | | | |
| | 1| 2| 3| 4
Circuit volume| | dm 3| | 0,2| 0,3| 0,5| 0,6
---|---|---|---|---|---|---|---
| Airflow| m 3 /h| | 270| 250| 460| 430
Fan (3)| Air throw (2)| m| | 3,5| 3,0| 6,0| 5,5
Num.| | 1| 1| 2| 2
---|---|---|---|---|---
W total| | 38| 38| 76| 76
| A total| | 0,33| 0,33| 0,66| 0,66
---|---|---|---|---|---|---
| Inlet| Ø ODF| | 5/16″| 5/16″| 5/16″| 5/16″
| Outlet| Ø ODF| | 5/16″| 5/16″| 5/16″| 5/16″
Net Weight| | kg| | 4| 4| 8| 9

Standard conditions

  • SC2 / 0 °C (air inlet temp.) / -8 °C (evaporating temp.) / DT1 = 8K
  • SC3 / -18 °C (air inlet temp.) / -25 °C (evaporating temp.) / DT1 = 7K
  • SC4 / -25 °C (air inlet temp.) / -31 °C (evaporating temp.) / DT1 = 6K
  • When the section of the room allows air circulation.
  • Closed motor, class B, protected by its impedance, long-lasting lubrication