CEM Instruments DT-91 Bluetooth Temperature and Humidity Tester User Manual

June 5, 2024
CEM Instruments

Professional Temperature & Humidity Meter
User Manual

Meter Description

  1. -Temperature/Humidity Sensor
  2. -LCD Display
  3. -Data Hold/Backlight button
  4. -MAX/MIN button
  5. -Power on/off button
  6. -Temperature button
  7. -Bluetooth button

Features

  1. Range: 0.0 —100.0%RH, -20.0°C — 60.0°C(-4.0°F 140.0°F); Resolution:0.1%RH, 0.1°C/0.1°F
  2. Dual Display Temperature& Humidity.
  3. Bluetooth 4.0
  4. MAX/MIN
  5. HOLD lock and backlight
  6. Measurable Dry bulb temperature, wet bulb temperature, Dew point Temperature
  7. Temperature unit switch
  8. Auto power off, Disable auto-power off.
Function Range Resolution Accuracy
Humidity 0∼100%RH 0.1%RH ±3.5%RH (20 ∼80%)
±5%RH (0 ∼ 20&80 ∼100%)
Dry bulb temperature -20 ∼ 60°C 0.1°C/°F ±0.5°C/0.9°F (0 ∼40°C)
-4 ∼140°F ±1°C/1.8°F (-20 ∼ 0&40 ∼60 °C)
Wet-bulb temperature 0 ∼ 60°C Holocron ±0.5°C/0.9°F (0∼40 °C)
32 ∼140°F ±1°C/1.8°F (40 ∼60 °C)
Dew point temperature -20.0 ∼ 60°C 0.1°C/°F ±0.5°C/0.9°F (0 ∼ 40 °C)
-4 ∼140°F ±1°C/1.8°F (-20 ∼0&40 ∼ 60°C)
Display Dual digital LCD display with backlight
--- ---
Sensor Type Humidity: Accurate capacitance sensor
Temperature: Thermistor
Low battery indication The low battery signal “∼”flashes when battery voltage

drops below 7.2V; The backlight and low battery signal “∼”flash twice when battery voltage drops below 6.5V, then auto power off.
Operating condition| 0 ∼50°C(32 ∼ 122°F)<80%RH non-condensing
Storage condition| -20 ∼60°C(-4 ∼140°F) <80%RH non-condensing
Power| One standard 9V battery.
Dimension| 204 (L) X 54 (W) X 36 (H) mm
Weight.| 172g

Operation instructions

  1. Power on/ off, Auto-power off:
    Power on: Short press button “o ” to power on, system default auto power off. Long press to power on and disable the auto power-off function. Long press the button again to enable the auto power-off function
    Power off :  Short press button ” 0″ to power off. Auto-power off:
    Auto-power off:   signal “0 ” displays in the left corner of the LCD and the instrument will auto-power off in 10minutes of no button operations. If press the power on/off button for over 1 minute, it will be recognized as faulty operation and the instrument will auto power off.

  2. Temperature:
    Short press to switch the measure temperature type: NULL(dry bulb temperature) →WB (wet bulb temperature) →DP (Dew point temperature) →NULL (dry bulb temperature), cycle in this order. Default measure dry bulb temperature; Long press temperature button to switch temperature unit, and cycle, in turn, °C →°F →,°C, the default unit is the last unit before power off.

  3. Bluetooth:
    Long Press once to enable the Bluetooth communication function; Long press once again to disable the function.

  4. MAX/ MIN:
    Press MAX/MIN button once and “MAX” appears on the display. The LCD is now displaying the maximum reading of the selected parameter in the display. The display reading will not change until a higher reading is registered. Press the MIN/MAX button again and “MIN” appears on the display. The LCD is now displaying the minimum reading of the selected parameter in the display. The display reading will not change until a lower reading is registered. Press the MIN/MAX button once again to exit the MIN/MAX mode, no “MAX/MIN” display on the LCD now. Cycle in order: NULL→. MAX →.MIN→. NULL.

  5. HOLD /Backlight:
    Press the Hold/backlight Button to enter the hold function, and the LCD displays “HOLD”. In hold mode, only the power button and the Hold/backlight button is enabled. Short press the button again to disable the hold function, no”Hold” displays on the LCD. Long press to enable the backlight and long press once again to disable the backlight.
    (Note: buttons 2, 3, 4, 5 can be enabled only when the instrument is powered on.)

  6. Meter box Pro Operation Download Meterbox Pro APP to the smartphone before using the Bluetooth communication function. Meter box Pro APP is compatible with instruments with Bluetooth: Laser Distance Meters, Multimeters Clamp Meters, Multifunction Insulation Tester, Environment Meter, etc. The Meterbox Pro for Environment Meter detailed introduction please look at the help files in GUIDE which is in the Environment Meter interface of Meterbox Pro.

Maintain

  1. The instrument should be cleaned with a damp cloth and non—irritating cleanser when necessary. Do not use corrosive and irritating cleanser.
  2. Pls, keep the instrument in a proper temp and humidity environment.

Battery Replacement

If the low battery signal appears on the LCD display, it indicates that the battery should be replaced. Open the battery cover with a screwer, then replace the exhausted battery with new battery.

Rev. 180115

Documents / Resources

| CEM Instruments DT-91 Bluetooth Temperature and Humidity Tester [pdf] User Manual
DT-91, Bluetooth Temperature and Humidity Tester, DT-91 Bluetooth Temperature and Humidity Tester
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals