Beta Three MU12M 12 Inch Two Way Full Range Monitor User Manual

June 5, 2024
Beta Three

Beta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-
logo

Beta Three MU12M 12 Inch Two Way Full Range Monitor

SAFETY INSTRUCTIONS

PLEASE READ THIS MANUAL FIRST

Thank you for buying the product. Read this manual first as it will help you operate the system properly. Please keep this manual for future reference.

  • WARNING: This product must be installed by professionals. When using hanging brackets or rigging other than those supplied with the product, please ensure they comply with the local safety codes.
  • CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL

The exclamation point within an equilateral triangle is intended to alert you to the presence of important operating and servicing instructions.

  • ATTENTION: Don’t refit the system or spare parts without being authorized as this will void the warranty.
  • WARNING: Don’t place naked flames (such as candles) close to the equipment.
  1. Read the instruction manual first before using this product.
  2. Please keep this manual for future reference
  3. Pay attention to all warnings.
  4. Obey all operating instructions.
  5. Do not expose this product to rain or moisture.
  6. Clean this equipment with a dry cloth.
  7. Do not block any ventilation openings. Install according to the manufacturer’s instructions .
  8. Do not install this product near any heat source, such as a heater, burner, or any other equipment with heat radiation.
  9. Only use spare parts supplied by the manufacturer.
  10. Pay attention to the safety symbol on the cover.

INTRODUCTION

Product information is subject to be updated without notification, please visit www.elderaudio.com for the latest update.

MU12 M 12″ two-way full-range monitor Features
  • 12″ Neodym ium w oofer w ith 3″ voice coil.
  • Neodymium compression driver with 3″ voice coil.
  • Dispersion 45 45 .o
  • Monitor angle 50 .
  • Sensitivity is 97dB, Max. SPL is 121dB.
  • RMS power is 350W, peak power is 1400W.
  • Ergonomic cabinet design.

Description

3 MU12M is a professional and compact monitor system, it is suitable for all the demanding monitor applications. Adopt ed Neodymium compression driver integrate 3″ polymer diaphragm to assure the big power output and delivery natural sound performance, the dispersion is 45 x45. 12″ Neodymium woofer integrates 3″ voice coil and latest improved magnet circuit&short-circuit ring to achieve the low distortion and Max. clarity under high SPL. Very compact design, lightweight, and very powerful. Perfect protection circuit design makes sure the system works smoothly and safely. MU12M produces 121dB SPL continuously and 80-16kHz frequency response, suitable for different applications from small to large scale, including speech and full-range applications. MU12M adopts the ergonomic cabinet design. Large arc cabinets effectively reduce the collision harm, and the round handle design makes the carrying very balanced during the transport. NL4 connectors are available on both sides to optimize the system wiring. The cabinet is made of 15mm Russian birch plywood so it had vancedenviron mental protection. polyurethane-based painting. The steel grille is coated with powder to provide strong ultra- Weatherability.

Applications

  • Auditorium
  • Theater
  • Multifunctional hall
  • Dance Club
  • Hall Performance
  • Living Performance

CONNECTION

Two o NL4 connectors are available for amplifier connections. The paralleled connector is very convenient for another speaker connection.

SpeakonBeta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-
fig-2  1+ 1- INPUT
Beta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-
fig-3

NL4 Wiring Connection
  1. ConnectBeta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-fig-4
  2. Disconnect

System Connection Reference

MU12 M-MU12 MBeta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-
fig-6

  • Attention: The impedance of the connected speaker must match the impedance of the amplifier output.
  • Attention: Make sure the polarity of the speaker and amplifier is correct.Beta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-fig-8

Speaker Wiring

  1. Banana plugs to NL4 Connect to amplifier & Connect to a speakerBeta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-fig-7
  2. NL4 to NL4 Connect to amplifier & Connect to a speakerBeta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-fig-9Beta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-fig-10

Consumption curve of connection cable(Only for reference, the result is different if adopting the different cables)Beta-Three-MU12M-12-Inch-Two-Way-
Full-Range-Monitor-fig-11

Specification

  • System: 12″ passive monitor
  • Components: 1 12″ Neodymium woofer 1 Neodymium compression driver with 3″ diaphragm
  • Frequency response(-3dB): 80Hz-16kHz
  • Sensitivit y(1W@1m ): 97dB
  • Max.SPL(1m ): 121dB/ 127dB(PEAK)
  • Power: 350W (RMS) 700W (MUSIC) 1400W (PEAK)
  • Dispersion H V: 45 x 45
  • Monitor angle: 50
  • Rated impedance: 8 Ohm s
  • Crossover point: 1.8kHz
  • Cabinet: Wedge shape
  • Handle: 2 Wooden handles
  • Surface: Polyurethane-based painting. Steel grille is coated by powder to provide strong ultra-Weatherability.
  • Connector: 2 NL4
  • Cabinet dimension: 410 x 548 x 450mm
  • (WD H): (16.1 21.6 17.7in)
  • Package dim ension: 650 x 500 x 510mm
  • (WD H): (25.6 19.7 20.1in)
  • N.W.(pc): 19.3kg(42.5lbs)
  • G.W.(pc): 21.5kg(47.3lbs)

Speaker testing method

  1. Frequency response
    Use Pink noise to test the speaker in the anechoic room, adjust the level to make the speaker work at its rated impedance and the power output is 1W, then test the frequency response 1m away from the speaker.

  2. Sensitivity
    Use full range Pink noise which was modified by EQ curve to test the speaker in the anechoic room, enlarge the signal to make the speaker work at its rated impedance and the power output is 1W, then test the sensitivity 1m away from the speaker.

  3. MAX.SPL
    Use full range Pink noise which was modified by EQ curve to test the speaker in the anechoic room, enlarge the signal to make the speaker work at its instant power output level, then test the SPL 1m away from the speaker.

  4. Rated Power
    Use the pink noise according to IEC#268-5 to test the speaker, and enlarge the signal for a continuous 100hours, the rated power is the power when the speaker will not incur hot damage or mechanics damage.

Frequency response curve & Impedance curve:Beta-Three-MU12M-12-Inch-Two-
Way-Full-Range-Monitor-fig-12

TECHNICAL SPECIFICATION

Top ViewBeta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-
fig-13

Side ViewBeta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-
fig-14

Front ViewBeta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-
fig-15

Rear ViewBeta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-
fig-16

Bottom ViewBeta-Three-MU12M-12-Inch-Two-Way-Full-Range-Monitor-
fig-17

Documents / Resources

| Beta Three MU12M 12 Inch Two Way Full Range Monitor [pdf] User Manual
MU12M, 12 Inch Two Way Full Range Monitor, MU12M 12 Inch Two Way Full Range Monitor
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Beta Three User Manuals

Related Manuals