MOXA ABC-02-USB Series Automatic Backup Configurator Installation Guide
- June 5, 2024
- MOXA
Table of Contents
MOXA ABC-02-USB Series Automatic Backup Configurator
Overview
The ABC-02-USB Automatic Backup Configurator is a device that can save and
load configuration files, backup event logs, and load firmware of Moxa’s
managed switch via the USB (universal serial bus) interface. The ABC-02-USB is
able to be accessed directly like a standard USB flash drive from a computer.
The ABC-02-USB makes it easier to manage the backup of system parameters or
perform configuration during the replacement of a switch. With the ABC-02-USB,
users can quickly re-install a substitute switch (of the same model) without
the need of a laptop computer. The ABC-02 can be used to recover the entire
system configuration, including the IP address, if a switch failure occurs.
Switches can load firmware from the ABC-02-USB and backup event logs to the
ABC-02-USB. It is also an easy and fast diagnostics tool for automation
engineers to retrieve configuration files and event logs in the field
immediately, without the need for laptop computers.
Package Checklist
The ABC-02-USB is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance.
- 1 x ABC-02-USB
- Quick installation guide (printed)
- Warranty card
Features
- Widely used USB 2.0 interface
- Click the switch rest button to back up the configuration file and event log to ABC-02
- Automatic loading of system configuration after system reboot
- Manual upgrade firmware from ABC-02 and backup event logs to ABC-02
- Manual and saving system configuration through web console
- Extend switch event log storage capability
- Portable low-power design that requires no power supply
- CE, FCC approval
Hardware Description
Product Installation
- The ABC-02-USB is designed for use with an USB 2.0 port. Plug the ABC-02 into the USB port of your Moxa managed switch. Securing the ABC-02 on the wall with an M4 screw is suggested.
- Avoid hanging the ABC-02 configurator from the switch without securing it onto the wall.
- Please refer to the Product Operation section for instructions on how to save and load the configuration, firmware, and event logs.
Product Operation
Configuration Backup and Restore
-
Backup switch configuration on the ABC-02
Use the switch web console to save the configuration file to the ABC-02. This function is found under “System/System Files/Configuration Backup and Restore “. Then select “Auto Backup Configurator (ABC-02)” in the web console. Click “Backup” to save the configuration file to the ABC-02. The file will be saved in the “:\Moxa” folder of the ABC-02. The file name is “Sys.ini”. -
Restore the configuration file from the ABC-02 to the switch
A. Manually operate in web console
Use the switch web console to load configuration files from the ABC-02 to the switch. This function is found under
“System/System Files/ Configuration Backup and Restore”. Then select “Auto Backup Configurator (ABC-02)” in the web console. Click “Browse” to select the file you need. Then click “Restore” to start loading into your switch.
B. Auto-load the configuration file from the ABC-02 to the system when the switch boots up
Power off your switch first, and then plug in the ABC-02. Then power on your switch, the system will detect the configuration file on the ABC-02 automatically. The switch will recognize the file name with following sequence priority:- ”MAC address last 6 digits.ini*”
- “Sys.ini”. If no matching configuration file is found, the fault LED light will turn on. The switch will boot up normally.
NOTE Please save your configuration files in the “:\Moxa” folder of the ABC-02. Auto-load will detect the configuration file using this path only.
Firmware Upgrade
Upgrade the firmware from the ABC-02 to the switch. You can download the
firmware file from http://www.Moxa.com/support/.
Save the firmware file in the “:\Moxa” folder of the ABC-02.
Plug in the ABC-02 into your switch. Use the switch web console to load the
switch firmware file from the ABC-02. This function is found under
“System/System Files/ Firmware Upgrade “. Then select “Auto Backup
Configurator (ABC-02)” in the web console. Click “Browse” to select the file
you need. Then click “Upgrade” to start loading the file into your switch.
Log File Backup
Backup the switch log file to the ABC-02
Use the switch web console to save the configuration file to the ABC-02. This
function is found under “System/System Files/ Log File Backup “. Then select
“Auto Backup Configurator (ABC-02)” in the web console. Click “Backup” to save
the configuration file to the ABC-02. The log file will be saved in the
“:\Moxa” folder of the ABC-02. The file will be named “Sys.log”.
One-click backup
The ABC-02 can backup configuration and log files from the switch. When the
ABC-02 is plugged into the switch, “STATE” LEDs on the switch will start to
blink slowly, and the reset function will be disabled automatically. Press the
“reset” button once and the switch will start backing up configuration files
and system logs to the ABC-02.
The “RESET” button is located on the front panel of rackmount type switches
and on the top panel of DIN-rail type switches.
Auto backup to the ABC-02 when configurations change
The ABC-02 is capable of backing up switch configuration files automatically.
This function is found under “System/System Files/ Configuration Backup and
Restore”. While the ABC-02 is plugged into the switch, enable the “Auto backup
to ABC-02 when configuration change” option. Then click “Apply”. Once this
configuration is modified, the switch will back up the current configuration
under the “/His_ini” folder in the ABC-02. The file name will be the system
date/time (MMDDHHmm.ini).
Auto backup of the earliest 100 log entries to prevent overwriting
This function is designed to maintain a long-term record the switch log files.
Moxa Ethernet switches are capable of saving 1000 entries of event logs. When
the 1000-entry storage limit is reached, the switch will delete the oldest
saved event log. The ABC-02 can help to backup these event logs. When switch
log entries reach 1000, the ABC-02 will back up the earliest 100 entries of
the switch.
The function is found under “System/System Files/ Log File Backup”. Enable the
“Auto backup the earliest 100 log entries to prevent overwriting”. Then click
“Apply”. After that, when the ABC-02 is plugged into the switch, the event
logs will always be saved to the ABC-02 automatically.
-
NOTE For further details on the ABC-02 operation through the switchweb console, please refer to the switch user manual.
-
WARNING
DO NOT remove the ABC-02 when the STATE LED is blinking or when the web console is showing WORKING status. -
NOTE The status of the ABC-02 may be checked on the switch web console or by observing the switch front panel LEDs.
Operation | Switch LED status |
---|
The switch detects
ABC-02-USB plugged in
| STATE blinking slowly (1 time/ 2
seconds),
Import/Export in
progress*
| FAULT, MASTER, COUPLER LEDs
Blink sequentially and circularly
Import/Export successful| FAULT, MASTER, COUPLER LEDs light
off
Save/Load failed| FAULT LED light on until ABC-02 is
removed or system reboot
Operation | ABC-02 LED status |
---|---|
Power on | ABC-02 STATE LED green light on |
Reading /Writing | ABC-02 STATE LED blinking |
- Does not include “Auto backup to the ABC-02 when configuration change” and ”Auto backup the earliest 100 log entries to prevent overwriting
Specifications
Connectors | USB 2.0 Type A |
---|---|
Power Requirement | 5 VDC, power input via the USB interface |
Configuration | via Moxa managed switch’s web console |
Casing | PVC molding, IP40 |
Weight | 50 g |
Installation | M4 screw (> 4 mm) |
Dimension (W × D × H) | 32.5 × 97 × 12 mm |
Cable Length | 32 cm, including connectors |
Operating Temperature | 0 to 60°C (32 to 140°F) |
-40 to 75°C (-40 to 167°F) for –T model
Storage Temperature| -20 to 70°C (-4 to 158°F)
-40 to 85°C (-40 to 185°F) for –T model
Ambient Relative
Humidity
| 5 % to 95 % (non-condensing)
EMI| FCC Part 15, CISPR (EN 55032) Class A
EMS| EN61000-4-2 (ESD), level 3 EN61000-4-3 (RS), level 3 EN61000-4-4 (EFT),
level 3
EN61000-4-5 (Surge), level 3
EN61000-4-6 (CS), level 3
Warranty| 5 years
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>