Leak Noise Correlator
LC-5000 Leak Correlator
Compact and Light-Weight.
The Main Processor Unit, weighing less than 5 lb., can easily be carried all
day
The Main Processor Unit displays up to 6 Correlations on one screen.
User can easily drill into individual correlation from touch screen.
Ruggedly Built & Weather-Tight
The Main Processor Unit and the Transmitter Sensors can operate in rain
storms, sub-zero temperatures and direct sun for hours.
Rechargeable Batteries
Runs all day on Lithium lon Batteries.
High Sensitivity Transmitting Sensors Standard
The new LC-5000 Transmitting Sensors are very sensitive, small in diameter,
and totally submersible. 4 times the resolution of its predecessor the
LC-2500.
Easy To Set Up & Run – 3
Steps & You Are On Your Way
Input pipe materials, diameters, and lengths by simply selecting them in the
program menus. Automatic functions can do the rest.
Easy To Set Up & Run
MAIN CORRELATION SCREEN, is the “home page” where every correlation
begins. Icons at the bottom relay signal & battery strength. In PIPE DATA
SCREEN , user enters Material, Diameter & Lengths from the easy touch screen
menu.
In FILTER SCREEN, user can adjust High & Low-Pass Filter ranges & adjust
Notch Filter.
In TRANSMITTER SENSOR SETTINGS, the user can program & send settings to
all units or select individual units for Relay or Relay & Pre-Amp Mode.
In PRE-AMPLIFIER / TRANSMITTER MODE, user has options for programming as
Transmitters, Relays, Transmitter / Relays or Logger Mode for overnight or
Short Term Deployment.
MENU SCREEN, is where user selects various functions like Data
processing, Logger data retrieval, Equipment seting as well as FFT & White
noise features. Powerful Transmitter with Radios That Go Over Hills and
Around Buildings
Pre-amp / Transmitter
“hear” the leak sounds at pipe locations and transmit them to the main
processor. aviation-grade stereo headphones are standard.
High sensitivity small diameter
LC-5000 Transmitter Sensors standard for all pipe materials.
Patented Submersible Sensors Deploying all 4
Transmitting Sensors allows for up to 6 correlations on Main Unit main
screen. 4-1 Radio and Cable Modes
(1) Radio mode (2) Cable mode
Cable mode is used when radio communication cannot be established between the
leak detector and the pre-amplifiers due to interference from buildings or
other radio stations etc.
Normally, leak detection is done in radio mode as shown in (1) above.
4-2 Example of Detecting a Leak in a
Pipe
This section explains how to perform leak detection for the pipe shown below.
In this example, it is assumed that the water leaks from a certain location in
the pipe. The pre-amplifiers detect the leak noise and send the signals to the
main unit. MODEL LC-5000
LEAK NOISE CORRELATOR
The LC-5000 System Includes:
- LC-5000 Main Processor Unit
- 2 or 4 Transmitting Integrated Sensors
- 6-inch Antenna Extensions
- Pedestals for Transmitting Sensors
- Headphones (see inside) & Battery Recharging Cables
- Instruction Manual and SDHC Card
- “Heavy Duty” Composite Carrying Case
Optional Accessories:
- External Sensors w/10-foot Cable
- Rechargeable Spare Battery for Main Unit
Specifiations
Main Processor Unit
- Operating Temperature Range : 10 to 140°F
- Applcable Standard : 1P52 (weather tight)
- Extemal Dimensions : 1 10.7 inches (W) x 7.0 inches (D) x 3.2 inches (H)
- Weight : Approx. 4.8 b. (with batteries)
- Battery : Lithium lon (rechargeablo)
- Continuous Operating Time : 8 hours minimum (at 20°C, backiight OFF)
- Minimum Operating Voltage : 4.2V
- Input : Radio x4 or Cable x2
- Display : 7-inch TFT LCD with touch soreen
- Operation : Polaiity correlation
- Td Range : +50ms, +100ms, d200ms, +400ms, +800ms, +1600ms, 3200ms or automatic setting
- Time Resolution : 25 ps (in £50ms range), 50 s (in +100ms range), 400 s (in =200ms range), 200 s (in +400ms range), 400 s (in +800ms range), 800 s (in +1600ms range)
- Fitor Rango : THRU, 80Hz 0 5,000Hz (4 low and 4 high)
- Notch Filter : OFF, 50Hz, 60Hz
- Auto Fiter : Automatically selected from FFT operation
- Data Memory : 100 correlations
- FFT Monitor : 1kHz, 2.5kHz, 5kHz (common to both channels)
- Sound Memory: For 16 seconds
- Extemal Interface : Antenna, Headphone, Power Switch, Cable, RS-232C
Red and Blue Pre-Amplifiers
-
Operating Temperature Range : 13 to 140°F
-
Applicable Standard : IP68 (weather tight)
-
Extemal Dimensions 314 inches (D) x 7.2 inches (H)
-
Weight : Approx. 6.3 b. (with batteries)
-
Battery : Lithium lon (rechargeable)
-
Continuous Operating Time: 10 hours minimum (at 20°C, backiight OFF)
-
Minimum Operating Voltage : 6.0V
-
Input
Input Frequency Range: 20Hz to 5kHz (at THRU fitr seting) 100Hz to 5KHz (at STD filter setting)
Input Sensitvity : 50 mico V., max.
Signal to Noise Ratio : 3648, min, -
Radio Communication System
Output Frequency : UHF under approved freq
Modulation: Direct frequency modulation
Qutput Power : 0.5W (500mW)
Output Impedance : 50Ω
Sensors
- Operation Modes : Correlation / Relay / Logger / Relay+Correlation
- Sensivity Settings : 2.0 (1 o 20) Stops Manual & Auto
- Fillr Seting Modes : Common Through
- Recording: Audio signal recording (300 Seconds, logger mode only)
- GPS Function: Transmit position coordinates & elevation to the Main Unit
- Weight: 220
Manufactured by:
SubSurface Instruments, Inc.
1230 Flightway Dr
De Pere, Wisconsin. 54115
info@ssilocators.com
Office: 920.347.1788
www.ssilocators.com
Distributed by:…………………
Documents / Resources
|
Subsurface Instruments LC-5000 Leak
Correlator
[pdf] Instruction Manual
LC-5000 Leak Correlator, LC-5000, Leak Correlator, Correlator
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>