ARCTiCA hed499 two door REFRIGERATION Instruction Manual

June 5, 2024
ARCTICA

ARCTiCA hed499 two door REFRIGERATION

ARCTiCA hed499 two door REFRIGERATION-PROD

INTRODUCTION

Please read instructions before using this appliance.

IMPORTANT SAFETY INSTRUCTION

  • To reduce the risk of fire, electric shock, or injury to persons when using your product, basic safety precautions should be followed, including the following.
  • This appliance must be properly installed and located in accordance with the Installation Instruction before it is used.
  • Before the appliance is plugged in, ensure that the rated voltage corresponds to the voltage of the electrical system in your home. The power plug should have its own independent socket. Using adapters may cause overheating or burning.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
  • Connect to properly grounded outlets only. Avoid the use of extension cords. Do not run cord under carpeting, runners or the like. Arrange cord away from traffic area and where it will not create a tripping hazard.
  • Always unplug appliance when not in use and before cleaning, adjusting or maintaining this machine. To disconnect appliance, turn switch off and remove plug from power source.
  • Do not disconnect by pulling on the cord. Always disconnect by grasping and pulling on the plug top.
  • Do not pull out the cord or touch the power plug with wet hands. Clean water or dust from the power plug and insert it with the ends of the pins securely connected.
  • Do not use outdoors.
  • Do not splash water on the appliance. It may cause a malfunction or electric shock.
  • Do not disassemble, repair or alter the appliance. It may cause fire or abnormal operations, which may lead to injury.
  • After your fridge-freezer is in operation, do not touch the cold surfaces in the freezer compartment, particularly when hands are damp or wet. Skin may adhere to these extremely cold surfaces.
  • Never place glass products in the freezer because they may be broken when their inner contents are frozen.
  • The refrigerant and insulation blowing gas used in the appliance require special disposal procedures. When disposal, please consult with service agent or a similarly qualified person.
  • Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
  • WARNING: Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-in.
  • WARNING: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  • WARNING: Do not damage the refrigerant circuit.
  • WARNING: Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.

Warning: Risk of fire / flammable materials
CAUTION: RISK OF FIRE AND EXPLOSION WITH FLAMMABLE REFRIGERANT R600a/ R290.

  • If you need the electronic version instruction manual, please ask the manufacturer or its service agent .

  • Max. Load of shelf is 80 kg.
    This instruction manual provides all the necessary information regarding: _.. use of the refrigerator

  • technical specifications

  • installation and handling

  • operator procedures and instructions

  • maintenance operation

The manual is to be considered an integral part of the refrigerator and should be stored in a safe place for father consult to permit a good working life of the refrigerator. The appliance is intended for commercial use only.

The manufacturer cannot be held liable in the following cases:

  • improper installation (not in accordance with the guidelines indicated herein)
  • misuse of the refrigerator
  • power supply defects
  • improper or inadequate maintenance
  • unauthorised modification or tampering
  • use of non-original spare parts
  • partial or total failure to comply with the instructions

All electrical equipment can be hazardous to health. Current standards and legal requirements must be complied with during the installation and use of any equipment.

TRANSPORTATION AND STORAGE

The equipment is wrapped in absorbent material and contained and fixed within a wooden platform and paper box.
Whist awaiting by definitive collection, these should be stored within a protected and covered environment at a temperature between -25°C / +55°C, with ambient humidity between 30°C / 95%. Do not stack more than three items.

COMMISSIONING

Carefully read the label on the equipment, do not cover for any reason whatsoever. and replace them immediately if damaged. Do not remove protection or panelling that require the usage of tools.
POSITIONING
Ensure that in respect of the dimensions, the space reserved for the equipment permits its correct utilization and ease of maintenance. After carefully unpacking the display case, remove the white PVC protective film and all of the manufacturer’s material that safeguards the item in transit. Place the cabinet on a flat surface and level it by screwing and adjusting the leveling legs to ensure its efficient operation. The cabinet must be lifted only from the exterior of the base to avoid the possibility of damage. Do not move the cabinet by application of pressure to the surface. if the device has been positioned horizontally ( integral condensing unit). wait two hours before activating it. Packing and the protective film should be disposed of off as indicated by the local authorities. The equipment must
not be installed within the explosive ambiance, In the open air or exposed to rain the correct siting is; distant from direct sources ( radiators, direct lighting, etc … ) and protected from direct sunlight and draughts. Air circulation must be freely maintained around the condensing unit, be it integral or remote. In observance of these specific conditions will detrimentally affect the cabinet.

INITIAL CLEANING

Before use all parts of the cabinet should be , cleaned, For the walls and all the internal parts use an antibacterial detergent. For the plastic parts use a moistened cloth. Dry with a soft clean cloth. use little or no water. Do not use harsh or abrasive solvents or detergents During cleaning do not approach bare-handed those parts which could cut ( evaporator, condenser, etc. )and always use protective gloves.

Electrical connectionARCTiCA hed499 two door REFRIGERATION-
FIG3

Check that the supply conforms to the requirements listed on the factory label and that it is provided with fail-safe protection or an automatic circuit breaker with an efficient earth connection. Should there not be an electrical safety feature have this introduced by a qualified person. by means of an omnipolar switch a means of an omnipolar switch as indicated in the safety regulations with a mini where the cabinet has to be installed at some distance from the electrical source. ensure that the conforms to the local provided with an appropriate plug fitted with a neutral and earth; the supply cable must be well stretched (avoid coilling and superimposition ). it must not be exposed or adapters.

CONNECTION TO DRAINS
The dispersal of defrost water is automatic in all models with integral condensing unit.

TECHNICAL CHARACTERISTICS

NOISE AND VIBRATION
The sound level of the equipment fitted with integral hermetic condensing unit does not exceed 70 dB ,it is therefore not necessary to provide sound insulation. Under normal conditions the equipment does not generate vibrations that affect the surroundings.

POSSIBLE USAGES
Do not utilise the equipment to store medical supplies. The optimum operational ambient temperatures are between +10 C / +32 C. C): refrigeration, preparation, and sale of salads, fruits. Vegetables and cold dishes.

USAGE

Operating Instruction

  1. These devices are activated by one or two switches and an electronic control panel.
  2. After connecting the power supply, press the “POWER” switch on the controller keyboard (Red Indicator Light ON), the fridge will come to work. The microcomputer controller, installed in the controller keyboard, could automatically adjust the temperature ranges. This intelligent digital controller works as: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again.
  3. Microcomputer Controller Operation Instruction:

Display and functions:

During normal operation, the controller displays the value of the probe set using parameter/4(=1 ambient probe, default,= 2-second probe, =3 third probe).ln addition, the display has LEDs that indicate the activation of the control functions(see Table 1 ), while the 3 buttons can be used to activate/deactivate some of the functions (see table 2).

LEDs and associated functions Tab.1 ARCTiCA hed499 two door REFRIGERATION-
FIG7

Table of functions activated by the buttons Tab.2  ARCTiCA hed499 two door
REFRIGERATION-FIG8

Setting the set point( desired temperature)

  • Press SET for 1 s the set value will start flashing after a few moments;
  • increase or decrease the value using UP or DOWN;
  • Press SET to confirm the new value.

Switching the device ON/OFF
Press UP for more than 3s. the control and defrost algorithms are now disabled and the instrument displays the message “OFF” alternating with the temperature read by the set probe.
Manual defrost
Press for DOWN more than 3s (the defrost starts only the temperature conditions are valid).
Continuous cycle
Press UP and DOWN together for more than 3s.
Table of alarms

Alam

code E0

| buzzer and

alarm relav active

| LED

ON

| Description

probe 1 error=control

| Parametri

c- oninvolt i

---|---|---|---|---
El| inactive| ON| probe 2 error=defrost| ldO=0/lJ
E2

I A

| inactive

active

| ON

ON

| probe 3 error=condenser externa l alarm| [ A4= 1 0]

[ A4= 1 0 Jl +A7 J

dOr| active| ON| open door alarm| [ A4=7/8][+A7]
LO| active| ON| low temperature alarm| ( A LJ[ Adj
HI

EE EF

| active inactive

inactive

| ON ON

ON

| high tem perature alarm

unit parameter error operat ing parameter error

| [AhJ lAdJ

Ed

dF

| inactive

inactive

| ON

ON

| defrost ended by timeout

defrost running

| (d P] [dt][ d4][A8]

(do—OJ

cht| inactive| ON| condenser dirty pre-alarm| [ A4= 1 0]
CHT| active| ON| condenser dirty alarm| [ A4= 1 0]
Etc| inactive| ON| dock alarm|

  1. Microcomputer panel sketch map, meanings of running indicator light, and LED showing.
  2. SET To display the target set point, in programming mode, it selects a parameter or confirms an operation. ARCTiCA hed499 two door REFRIGERATION-FIG10
  3. How to see the point. Push and immediately release the SET key, the set point will be shown; Push and immediately release the SET key or wait about Ss to return to normal visualization.
  4. How to change the setpoint. Push the SET key for more than 2 seconds to change the Setpoint value; The value of the set point will be displayed and the “°C” or “°F” LED starts blinking; To change the Set value push the A or “1::;?Aux arrows. To memorize the new set point value push the SET key again or wait for 10s.
  5. How to start a manual defrost. Push the DEF :J:l key for more than 2 seconds and a manual defrost will start.
  6. 6. How to change a parameter value To change the parameter’s value operate as follows: Enter the Programming mode by pressing the SET+ keys for 3s (“°C” or “°F” LED starts blinking). Select the required parameter. Press the “SET” key to display its value Use A or “‘7AuX to change its value. Press “SET’ to store the new value and move to the following parameter. To exit: Press SET+A or wait for 15s without pressing a key. NOTE: the set value is stored even when the procedure is exited by waiting for the time-out to expire.
  7. To lock the keyboard. Keep pressed for more than 3s of the +A keys. The “OF” message will be displayed and the keyboard will be locked. If a key is pressed more than 3s the “OF’ message will be displayed.
  8. To unlock the keyboard. Keep pressed together for more than 3s of the +A keys till the “on” message will be displayed.
  9. Alarm signalingARCTiCA hed499 two door REFRIGERATION-FIG11

STORAGE OF FOOD-STUFFS

In order to obtain the best functioning of the case it is necessary to observe the following instruction:

  • Place the merchandise into the unit only after it has reached the desired operating temperature given on the digital display.
  • Do not place uncovered hot foods or liquids inside the unit
  • Package or protect foods when possible
  • Do not limit the circulation of air inside the call with superfluous obstacles.
  • Avoid frequent or prolonged openings of the door/drawers
  • Wait a few moments before reopening the door/drawer just after it has been closed.

Whilst stocking only open and fill a drawer at a time to eliminate the risk of over-balancing or ask to the supplier the fixable feets.

MAINTENANCE

For hygienic reasons and improved performance clean at least once a month the internal basin. Especially the hole for water out going, need keep clean always, First perform a manual defrosting cycle ( par. 6.1 ), When complete, switch off the power supply and clean the inside following the instructions given in par. 4.2 ( initial cleaning ).

CLEANING OF CONDENSER

For improved performance clean the condenser at least once Before beginning turn off the equipment, and disconnect the plug. Close and protect the unit.

  • Unscrew, rotate and remove the protective grill
  • Remove the dust deposited on the front surface of the condenser using a brush and a vacuum cleaner and restore previous conditions.

PERIOD OF INACTIVITY OF CABINET
During periods of inactivity, remove the products from the cabinet and then follow these directions:

  • Remove the plug out from the outlet and carefully clean the unit as per periodic cleaning
  • Cover the cabinet whit a cloth that allows air circulation in the interior.

TROUBLESHOOTING AND REMEDIES

Often, the malfunction of a unit is due to simple causes which can easily be eliminated without contacting a technician. Therefore execute the following controls

If the cabinet does not operate, make sure that:

  • The plug has been correctly inserted into the socket.
  • The supply cord is not damaged.

If the required temperature is not achieved, make sure that;

  • The command switch is turned on.
  • The electronic control panel is correctly regulated ( see 6.1. 3).
  • The cabinet is neither in the defrosting phase nor in the post-defrosting pase.
  • The evaporator is not covered with frost ( see 6.1.3).
  • The condenser is not blocked with dust.
  • The cabinet is not located near heat sources or its condensing unit has uninterrupted air flow.
  • The stored foods or other objects do not inhibit proper closing of the unit.
  • The cabinet is not working in anomalous conditions ( overloaded, I oaded with hot food, or loaded in a way that prevents proper air circulation ).

If the cabinet leaks water, make that:

  • The collecting container or the device for condensing water elimination are not damaged.
  • The discharge outlets are not blocked or obstructed.
  • The cabinet has been properly leveled.

If the cabinet is unacceptably noisy, make sure that:

  • The frame does not have loose screws or bolts.
  • The cabinet has been laid in a stable position and correctly leveled.

If, after all these controls, the malfunctioning continues, it is advisable to contact technical assistance. Be prepared to supply the following information:

  • The model trade name and the serial number (both can be found on the technical data plate ).
  • The alarm codes appearing on the display of the control panel.

IMPROBABLE RISKS
In case of fire unplug the cabinet, if possible, and use a powder fire extinguisher.

SUBSTITUTION OF SPARES

Before commencing any service or maintenance work, isolate the cabinet from the electrical supply. Always fit original spares which may be obtained from an authorized concessionaire or stockist.

DISMANTLING

The scrapping of the cabinet requires to be undertaken by a specialized company, licensed by the local authorities, and observing local statutes. Polyurethane foaming material, not fire-resistant, when dealing with the material, should be according to local law and statute.

  • The cabinet consists of:
  • Structure in steel plate,
  • Electrical components and cables,
  • Electrical compressor.
  • Plastic materials,
  • The refrigerant fluid must not be discharged into the atmosphere.

ALL THE RESPONSIBILITY FOR THE FAILURE TO RESPECT THE EXISTING LOCAL STATUTES ARE THE RESPONSIBILITY OF THE OWER.
Meaning of crossed-out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available.If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well -being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.

Circuit diagram

ARCTiCA hed499 two door REFRIGERATION-
FIG15

OFFICIAL APPROVAL AND RULES

Our products full fill the present E.U. rules, including the CE mark of the European official approval Latest version of following directives and standards

TECHNICAL PARAMETERS

S al adat t e Product (EN)

HEF570

|

HEF569

|

HEF568

| HED501| HED500| HED499|

Model

220-240V, 50Hz| 220-240V, 50Hz| 220-240V, 50Hz| 220-240V, 50Hz| 220-240V, 50Hz| 220-240V, 50Hz|

Rated voltage

310| 310| 310| 310| 220| 220| Rated power (W)
2| 2| 2| 2| 1.2| 1.2| Current (A)
380| 380| 300| 300| 380| 300| Volume (L)
4, 5| 4, 5| 4, 5| 4, 5| 4, 5| 4, 5| Safety climate class
R600a| R600a| R600a| R600a| R600a| R600a|

Refrigerant

70| 70| 60| 60| 70| 60| Amount (g)
1365 x 700 x 1040| 1365 x 700 x 888| 900 x 700 x 888| 900 x 700 x 1040| 1365 x 700 x 880| 900 x 700 x 880|

Dimension W×D×H(mm)

–| –| –| 204| 254| 169| Net volume (L)
2.55| 2.55| 2.12| 2.12| 1.6| 1.16| Energy consumption over 24 hours (E24h)
–| –| –| 723| 584| 423| Annual energy consumption (AEC)
–| –| –| 30| 24| 19| Energy efficiency index (EEI)
–| –| –| B| A| A| Energy efficiency class

NOTES: If the technical data has any changes, we will not notify you any longer.

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled Mwaste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ARCTICA User Manuals

Related Manuals