ARCTICA REFRIGERATION HEF141 3 Door Commercial Refrigerated Counter Instruction Manual
- June 4, 2024
- ARCTICA REFRIGERATION
Table of Contents
- ARCTICA REFRIGERATION HEF141 3 Door Commercial Refrigerated Counter
- IMPORTANT SAFETY INSTRUCTION
- Use of the equipment
- Technical features
- Control unit
- Handling
- Installation procedure
- Connecting to the main power supply
- Maintenance instructions
- Troubleshooting
- Technical service
- Configuration Sketch Map
- TECHNICAL PARAMETERS
- CORRECT DISPOSAL OF THIS PRODUCT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ARCTICA REFRIGERATION HEF141 3 Door Commercial Refrigerated Counter
Preface
Please read instructions before using this appliance.
IMPORTANT SAFETY INSTRUCTION
- To reduce the risk of fire, electric shock, or injury to persons when using your product, basic safety precautions should be followed, including the following.
- This appliance must be properly installed and located in accordance with the Installation Instruction before it is used.
- Before the appliance is plugged in, ensure that the rated voltage corresponds to the voltage of the electrical system in your home. The power plug should have its own independent socket. Using adapters may cause overheating or burning.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
- Connect to properly grounded outlets only. Avoid the use of extension cords. Do not run cord under carpeting, runners or the like. Arrange cord away from traffic area and where it will not create a tripping hazard.
- Always unplug appliance when not in use and before cleaning, adjusting or maintaining this machine. To disconnect appliance, turn switch off and remove plug from power source.
- Do not disconnect by pulling on the cord. Always disconnect by grasping and pulling on the plug top.
- Do not pull out the cord or touch the power plug with wet hands. Clean water or dust from the power plug and insert it with the ends of the pins securely connected.
- Do not use outdoors.
- Do not splash water on the appliance. It may cause a malfunction or electric shock.
- Do not disassemble, repair or alter the appliance. It may cause fire or abnormal operations, which may lead to injury.
- After your fridge-freezer is in operation, do not touch the cold surfaces in the freezer compartment, particularly when hands are damp or wet. Skin may adhere to these extremely cold surfaces.
- Never place glass products in the freezer because they may be broken when their inner contents are frozen.
- The refrigerant and insulation blowing gas used in the appliance require special disposal procedures. When disposal, please consult with service agent or a similarly qualified person.
- . Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- WARNING: Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-in.
- Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
- Do not damage the refrigerant circuit.
- Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
Warning: Risk of fire / flammable materials
CAUTION: RISK OF FIRE AND EXPLOSION WITH FLAMMABLE REFRIGERANT R600a/
R290.
- If you need the electronic version instruction manual, please ask the manufacturer or its service agent.
- Max. Load of shelf is 40 kg.
This instruction manual provides all the necessary information regarding:
- use of the refrigerator
- technical specifications
- installation and handling
- operator procedures and instructions
- maintenance operation
The manual is to be considered an integral part of the refrigerator and should
be stored in a safe place for father consult to permit a good working life of
the refrigerator.
The appliance is intended for commercial use only.
The manufacturer cannot be held liable in the following cases:
- improper installation (not in accordance with the guidelines indicated herein)
- misuse of the refrigerator
- power supply defects
- improper or inadequate maintenance
- unauthorized modification or tampering
- use of non-original spare parts
- partial or total failure to comply with the instructions
All electrical equipment can be hazardous to health. Current standards and legal requirements must be complied with during the installation and use of any equipment.
Use of the equipment
The refrigerator are for preserving fresh perishable foodstuffs, with an in-
built refrigerated unit.
The operating temperature for refrigeration is:
-
between 0 C and +8 C at room temperature of +43 C an 40%RD.
Climate class 4/5.
The operating temperature for frozen food maintenance is: -
between -22 C and -1 TC at room temperature of +43 C an 40% RD. Climate class 4/5 .
Technical features
The refrigerator is a ventilated system, the evaporator is in a separate insulated box on the top. All the materials used in the manufacture of this unit are guaranteed to be suitable for use with foodstuffs. The gases used in refrigerator is R600a; in the freezer is R290.
Control unit
The refrigerator is command from a “digital control unit and a “main switch pilot light in the top panel of the refrigerator. The “main switch pilot light is for turning on the power supply. The green pilot light comes on to indicate that the unit is connected to the main electricity and to start work. The green pilot light comes off to indicate that the unit is disconnected and don1 t work. The “digital control unit is for the regulation of all parameters to provide the correct working of the refrigerator. Please consult all parameters in the attachment manual of the “digital control unit. This attachment manual of “digital control unie is part of the instruction manual and is very important in case of service.
Handling
The refrigerator arrive in PET film and packed in cardboard box on a wood pal
let.
The refrigerator must be transported and handled with care to avoid posing a
hazard to persons or property. Never place a refrigerator with an in-built
refrigerated unit on its side or turn it upside down as this may damage or
impair operation of the refrigerated unit. We can not held liable for any
damage or defects arising directly or indirectly from improper handling of the
equipment or non-compliance with the safeguards illustrated above.
Installation procedure
-
Place the refrigerator in the coolest and best ventilated part of the room. Don’t install the refrigerator in the near of heat and direct sunlight sources.
-
Remove the straps securing the cardboard packing
Remove the cardboard. Covering
Remove the PET protection film -
Clean the refrigerator with mild detergent and then dry it with a soft cloth.
Connecting to the main power supply
This professionally operation and must be qualified carried persons. out by
Professionally and qualified person
The refrigerator are
supplied complete with a power supply cable for the connection to the main
power supply. A thermomagnetic circuit breaker (not supplied) must
be installed between the mains power point and the power supply cable of the
refrigerator.
**Before operation make sure that:
**
-
the mains voltage corresponds to the voltage on the refrigerator 220-240V/50Hz/1 Ph; to ensure proper operation it is essential for the power supply voltage to come within a range of+/- 10% of the unit’s rated voltage
-
the electronic system to which the refrigerator is connected is made in compliance with current standard requirements
-
the electric connections and the installation of the thermomagnetic circuit breaker have to be done by qualified person.
Connecting steps:
- Install a thermomagnetic circuit breaker suited to the rated output of the unit being installed
- Connect the refrigerator unit to the thermomagnetic circuit breaker outlet
- Check that the refrigerator is in order as demonstrated by the pilot light incorporated in the main switch coming on
Maintenance instructions
The smooth operation and life of the equipment are mainly determined by correct and regular maintenance
Cleaning:
Regular cleaning of the refrigerator unit is strongly recommended each month.
Please follow the instructions below.
Disconnect the refrigerator power supply cable from the W mains prior to
carrying out any type of cleaning operation.
-
Cleaning the refrigerator surface:
Clean the refrigerator with mild detergent and then dry it with a soft cloth.
Do not use abrasive detergents!
-
Cleaning the inside of the refrigerator:
Clean the inside area at least. each month with a detergent suitable for use with foodstuffs. -
Cleaning the condenser:
For an efficient operation of the refrigerator it is advisable to clean the condenser regularly approx. every 4 months with a dry brush or vacuum cleaner.
Troubleshooting
-
Refrigerator stops working (light off):
- Power supply failure
-
Remedies:
-
Check that the plug is inserted properly in the socket
-
Check that the switch on/off
-
Check that the mains voltage powers the plug
Refrigerator temperature go u p: -
Unit too near to a heat source
-
Condenser dirty or close
-
-
Remedies:
- Move the product or the heat source further away
- Clean the condenser
Technical service
For, technical service please contact the dealer technical department and give him the serial N2, and the date of buy.
Configuration Sketch Map
- Power switch
- Digital controller
- Front top panel
- Lock
- Power cord and power plug
- Adjustable feet/ wheels
- Door
- Door gasket
- Air deflector
- Shelf
- Hinge
Operating Instructions
-
New upright air-cooling refrigerator should be opened and ventilate it before it is in use.
-
After connecting the power supply, press the “POWER,, switch on the controller keyboard (Green Indicator Light ON), the fridge will come to work. The microcomputer controller, installed in the controller keyboard, could automatically adjust the temperature ranges. This intelligent digital controller works as: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again.
-
Microcomputer Controller Operation Instruction:
Display and functions:
During normal operation,
the controller displays the value of the probe set using parameter/4(=1
ambient probe, default,=2 second probe, =3 third probe).ln addition, the
display has LEDs that indicate the activation of the control functions(see
Table 1 ),while the 3 buttons can be used to activate/deactivate some of the
functions .
LEDs and associated functions
icon| function|
normal operation
| start up
---|---|---|---
ON| OFF| blink
| Compressor| on| off| request| ON
| fan| on| off| request| ON
| defrost| on| off| request| ON
AUX| aux| output on| output off| –| ON
| alarm| all| no alarm| –| ON
| clock| RTC fitted and enabled ,at least 1 time band set| KI C not fitted or
disabled not even 1 time band set| –| ON if RTC fitted
Table of functions activated by the buttons
setting the set point(desired temperature)
- press SET for 1 s the set value will start flashing after a few moments;
- increase or decrease the value using UP or DOWN;
- press SET to confirm the new value.
Switching the device ON/OFF
Press UP for more than 3s. the control and defrost algorithms are now disabled
and the instrument displays the message “OFF” alternating with the temperature
read by the set probe.
Manual defrost
Press for DOWN more than 3s (the defrost starts only the temperature
conditions are valid).
Continuous cycle
Press UP and DOWN together for more than 3s.
Table of alarms
-
Microcomputer panel sketch map, meanings of running indicator light and LED showing.
-
SET To display target set point, in programming mode it selects a parameter or confirm an operation.
- To start a manual defrost
- In programming mode it browses the parameter codes or increases the displayed value.
- In programming mode it browses the parameter codes or decreases the displayed value.
- To lock or unlock the keyboard SET
- To enter in programming mode
- To return to room temperature display .
-
How to see the point .
-
* Push and immediately release the SET key, the set point will be showed;
- Push and immediately release the SET key or wait about 5s to return to normal visualization.
-
-
How to change the setpoint .
- Push the SET key for more than 2 seconds to change the Set point value;
- The value of the set point will be displayed and the “°C” or “°F” LED starts blinking;
- To change the Set value push the Aux arrows.
- To memorize the new set point value push the SET key again or wait 10s.
-
How to start a manual defrost .
Push the DEF key for more than 2 seconds and a manual defrost will start. -
How to change a parameter value
- To change the parameter’s value operate as follows:
- Enter the Programming mode by pressing the SET keys for 3s (“°C” or “°F” LED starts blinking).
- Select the required parameter. Press the “SET” key to display its value Use A or Aux to change its value.
- Press “SET” to store the new value and move to the following parameter. To exit: Press SET+A or wait 15s without pressing a key.
NOTE: the set value is stored even when the procedure is exited by waiting the time-out to expire.
-
To lock the keyboard .
- Keep pressed for more than 3s the keys.
The “OF” message will be displayed and the keyboard will be locked. If a key is pressed more than 3s the “OF” message will be displayed.
- Keep pressed for more than 3s the keys.
-
To unlock the keyboard .
Keep pressed together for more than 3s the keys till the “on” message will be displayed . -
Alarm signalling .
Our products have been modified precisely before leaving factory, so to avoid damaging compressor unit or other malfunctions, users must n’ t modify the microcomputer parameters privately
TECHNICAL PARAMETERS
NOTES :If the technical data has any changes, we will not notify you any longer
CORRECT DISPOSAL OF THIS PRODUCT
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and
collection systems or contact the retailer where the product was purchased.
They can take this product for environmental safe recycling
-
To prevent unpredictable damages during the transportation process we fix the bottom shelves on the position
-
Before using please remove the cable ties and move the bottom shelves and bottom shelf chutes to the position to obtain the maximum net volume
-
If needed, you can adjust the shelf position by yourself
Read User Manual Online (PDF format)