ARCTICA HED235 Heavy Duty Single Door Upright Fridge, 670 Litres Instruction Manual
- June 4, 2024
- ARCTICA
Table of Contents
- HED235 Heavy Duty Single Door Upright Fridge, 670 Litres
- Preface
- Use of the equipm ent
- Technical features
- Control unit
- Handling
- Installation procedure
- Connecting to the main power supply
- Maintenance instructions
- Troubleshooting
- Technical service
- Configuration Sketch Map
- Operating Instruction
- Technical Parameters
- OFFICIAL APPROVAL AND RULES
- CORRECT DISPOSAL OF THIS PRODUCT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HED235 Heavy Duty Single Door Upright Fridge, 670 Litres
Instruction Manual
HED235 Heavy Duty Single Door Upright Fridge, 670 Litres
Upright Refrigerator & Freezer
Warranty Tel: 03701 647 647
Email: service@lockhartcatering.com
Please read the user’s manual before you use this product. If you request
unnecessary services, you may waste money.
Preface
Please read the instructions before using this appliance.
IMPORTANT SAFETY INSTRUCTION
▲ To reduce the risk of fire, electric shock, or injury to persons when using
your product, basic safety precautions should be followed, including the
following.
▲ This appliance must be properly installed and located in accordance with the
Installation Instructions before it is used. with the Installation Instruction
before it is used.
▲ Before the appliance is plugged in, ensure that the rated voltage
corresponds to the voltage of the electrical system in your home. The power
plug should have its own independent socket. Using adapters may cause
overheating or burning.
▲ This appliance can be used by children aged 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved.
▲ Children shall not play with the appliance.
▲ Cleaning and user maintenance shall not be made by children without
supervision.
▲ If the supply cord is damaged, it must be replaced by the manufacturer or
its service agent or a similarly qualified person in order to avoid or its
service agent or a similarly qualified person in order to avoid a hazard.
▲ Connect to properly grounded outlets only. Avoid the use of extension cords.
Do not run cords under carpeting, runners, or the like. Arrange the cord away
from the traffic area and where it will not create a tripping hazard.
▲ Always unplug the appliance when not in use and before cleaning, adjusting
or maintaining this machine. To disconnect the appliance, turn the switch off
and remove the plug from the power source. switch off and remove the plug from
the power source.
▲ Do not disconnect by pulling on the cord. Always disconnect by grasping and
pulling on the plug top.
▲ Do not pull out the cord or touch the power plug with wet hands. Clean water
or dust from the power plug and insert it with the ends of the pins securely
connected.
▲ Do not use outdoors.
▲ Do not splash water on the appliance. It may cause a malfunction or
▲ Do not splash water on the appliance. It may cause a malfunction or electric
shock.
▲ Do not disassemble, repair or alter the appliance. It may cause fire or
abnormal operations, which may lead to injury.
▲ After your fridge freezer is in operation, do not touch the cold surfaces in
the freezer compartment, particularly when your hands are damp or wet. The
skin may adhere to these extremely cold surfaces.
▲ Never place glass products in the freezer because they may be broken when
their inner contents are frozen.
▲ The refrigerant and insulation blowing gas used in the appliance require
special disposal procedures. When disposal, please consult with a service
agent or a similarly qualified person.
▲ Do not store explosive substances such as aerosol cans with a flammable
propellant in this appliance.
▲ WARNING: Keep clear of obstructions all ventilation openings in the
appliance enclosure or in the structure for building-in.
▲ WARNING: Do not use mechanical devices or other means to accelerate the
defrosting process, other than those recommended by the manufacturer.
▲ WARNING: Do not damage the refrigerant circuit.
▲ WARNING: Do not use electrical appliances inside the food storage
compartments of the appliance, unless they are of the type recommended
compartments of the appliance, unless they are of the type recommended by the
manufacturer.
**Warning: Risk of fire/flammable materials
CAUTION: RISK OF FIRE AND EXPLOSION WITH FLAMMABLE REFRIGERANT R600a/ R290.
** ▲ If you need the electronic version instruction manual, please ask the
manufacturer or its service agent .
▲ Max. The load of the shelf is 80 kg. This instruction manual provides all
the necessary information regarding:
▲ use of the refrigerator
▲ technical specifications
▲ installation and handling
▲ operator procedures and instructions
▲ maintenance operation
The manual is to be considered an integral part of the refrigerator and The
manual is to be considered an integral part of the refrigerator and should be
stored in a safe place for father consult to permit a good working life of the
refrigerator.
The appliance is intended for commercial use only.
The manufacturer cannot be held liable in the following cases:
■ improper installation (not in accordance with the guidelines indicated
herein)
■ misuse of the refrigerator
■ power supply defects
■ improper or inadequate maintenance
■ unauthorized modification or tampering
■ use of non-original spare parts
■ use of non-original spare parts
■ partial or total failure to comply with the instructions
All electrical equipment can be hazardous to health. Current standards and
legal requirements must be complied with during the installation and use of
any equipment.
Use of the equipm ent
The refrigerator are for preserving fresh perishable foodstuffs, with an in-
built refrigerated unit.
The operating temperature for refrigeration is:
■ between 0℃ and +8℃ at room temperature of +43℃ and 40%RD. Climate class 4/5.
The operating temperature for frozen food maintenance is:
■ between -22
■ between -22℃ and -17℃ at room temperature of +43℃ and 40% RD. Climate class
4/5.
Technical features
The refrigerator is a ventilated system, the evaporator is in a separate insulated box on the top. All the materials used in the manufacture of this unit are guaranteed to be suitable for use with foodstuffs. The gas used in the refrigerator is R600a; in the freezer is R290.
Control unit
The refrigerator is commanded from a “digital control unit” and a “main switch
pilot light” in the top panel of the refrigerator. The “main switch pilot
light” is for turning on the power supply. The green pilot light comes on to
indicate that the unit is connected to the main electricity and to start work.
The green pilot light comes off to indicate that the unit is disconnected and
don and don’t work. The “digital control unit” is for the regulation of all
parameters to provide the correct working of the refrigerator. Please consult
all parameters in the attachment manual of the “digital control unit”. This
attachment manual of the “digital control unit” is part of the instruction
manual and is very important in the case of service.
Handling
The refrigerator arrive in PET film and was packed in a cardboard box on a
wooden pallet.
**** The refrigerator must be transported and handled with care to avoid
posing a hazard to persons or property.
Never place a refrigerator
with an in-built refrigerated unit on its side or turn it upside down as this
may damage or impair operation of the refrigerated unit. We can not be held
liable for any damage or defects arising directly or indirectly from improper
handling of the equipment or non-compliance with the safeguards illustrated
above.
Installation procedure
▲ Place the refrigerator in the coolest and best-ventilated part of the room.
Don’t install the refrigerator in near of heat and direct sunlight sources.
▲Remove the straps securing
the cardboard packing Remove the cardboard. Covering Remove the PET protection
film
▲Clean the refrigerator with mild detergent and then dry it with a soft cloth.
Connecting to the main power supply
**** This operation must be carried out by professional and qualified
persons.
The refrigerator are supplied complete with a power supply cable for the
connection to the main power supply. A thermomagnetic circuit breaker (not
supplied) mustbe installed between the mains power point and the power supply
cable of the refrigerator.
Before operation make sure that:
▲ the mains voltage corresponds to the voltage o the refrigerator
220-240V/50Hz/1Ph; to ensure proper operation it is essential for the power
supply voltage to come within a
range of +/- 10% of the unit’s rated voltage▲ the electronic system to which the refrigerator
is connected is made in compliance with current standard requirements
▲ the electric connections and the installation of the thermomagnetic circuit
breaker have to be done by qualified person.
Connecting steps:
▲ Install a thermomagnetic circuit breaker suited to the rated output of the
unit being installed
▲ Connect the refrigerator unit to the thermomagnetic circuit breaker outlet
▲ Check that the refrigerator is in order as demonstrated by the pilot light
incorporated in the main switch coming on
Maintenance instructions
The smooth operation and life of the equipment are mainly determined by
correct and regular maintenance
Cleaning:
Regular cleaning of the refrigerator unit is strongly recommended each month.
Please follow the instructions below.
**** Disconnect the refrigerator power supply cable from the mains prior to
carrying out any type of cleaning operation.
Cleaning the refrigerator surface:
Clean the refrigerator with mild detergent and then dry it with a soft cloth.
Do not use abrasive detergents!
Cleaning the inside of the refrigerator:
Clean the inside area at least. each month with a detergent suitable fuse with
foodstuffs.
Cleaning the condenser:
For the efficient operation of the refrigerator, it is advisable to clean the
condenser regularly approx. every 4 months with a dry brush or vacuum
cleaner.
Troubleshooting
Refrigerator stops working (light off):
☆ Power supply failure
▲ Remedies:
☆ Check that the plug is inserted properly in the socket
☆ Check that the switch is on/off
☆ Check that the mains voltage powers the plug
Refrigerator temperature goes up:
☆ Unit too near to a heat source
☆ Condenser dirty or close
▲ Remedies:
☆ Move the product or the heat source further away
☆ Clean the condenser
Technical service
For technical service please contact the dealer technical department and give him the serial No, and the date of buy.
Configuration Sketch Map
1. Power switch
2. Digital controller
3. Front top panel
4. Lock
5. Door switch
6. Lamp
7. Door7. Door
8. Door gasket| 9. Pilastor for shelf
10. Shelf chute
11. Shelf
12. Bottom shelf
13. Adjustable feet / wheels
14. Power cord and power plug
14. Power cord and power plug
15. Air deflector
16. Door supporter
---|---
Operating Instruction
-
The new upright air-cooling refrigerator should be opened and ventilated it before it is in use.
-
After connecting the power supply, press the “POWER” switch on the controller keyboard (Green Indicator Light ON), and the fridge will come to work. The microcomputer controller, installed in the controller keyboard, could automatically adjust the temperature ranges. This intelligent digital controller works as: if the temperature ranges. This intelligent digital controller works as: if the temperature increases and reaches the set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again.
-
Microcomputer Controller Operation Instruction:
Display and functions:
During normal operation, the controller displays the value of the probe set using parameter/4(=1 ambient probe, default,= 2-second probe, =3 third probe), In addition, the display has LEDs that indicate the activation of the control functions(see Table 1), while the 3 buttons can be used to activate/deactivate some of the functions (see table 2). LEDs and associated functions Tab.1
icon | function | normal operation | start up |
---|---|---|---|
ON | OFF | blink | |
Compressor | on | off | request |
fan | on | off | request |
on | defrost | ||
off | request | ||
Aux | aux | output on | output off |
alarm | all | no alarm | – |
clock | RTC fitted and enabled, at least 1-time band set | RTC is not fitted | |
or disabled, not even 1-time band set | – | ON if RTC fitted |
Table of functions activated by the buttons Tab.2
button | normal operation | start up |
---|---|---|
pressing the button alone | pressed together | |
up ON/OFF | more than 3s toggle ON/OFF | pressed |
together start/ stop continuous cycle | – | |
down defrost | more than 3s: start/stop defrost | Pressed |
together start the parameter reset procedure | for ‘I s display firmware vers. |
code
| set mute| -1s: display/set the set point -more than 3s: access parameter
setting menu(enter password 22) -mute audible alarm (buzzer)| –
for 1 s RESET current EZY set
Setting the set point(desired temperature)
– press SET for is the set value will start flashing after a few moments;
– increase or decrease the value using UP or DOWN;
– press SET to confirm the new value.
Switching the device ON/OFF
Press UP for more than 3s. the control and defrost algorithms are now disabled
and the instrument displays the message “OFF” alternating with the temperature
read by the set probe.
Manual defrost
Press for DOWN more than 3s (the defrost starts only the temperature
conditions are valid).
Continuous cycle
Press UP and DOWN together for more than 3s.
Table of alarms
Ala m code | buzzer and alarm relay | LED | Description | Parametri coninvolti |
---|---|---|---|---|
E0 | active | ON | probe 1 error=control | |
El | inactive | ON | probe 2 en-or=defrost | IdGL-0/1] |
E2 | inactive | ON | probe 3 error=condenser | [A4=10] |
IA | active | ON | external alarm | [A4=10][+A7] |
dOr | active | ON | open door alarm | [A4=7/8][+A7] |
LO | active | ON | low-temperature alarm | [AL][Ad] |
HI | active | ON | high-temperature alarm | [Ah][Ad] |
EE | inactive | ON | unit parameter error | – |
EF | inactive | ON | operating parameter error | – |
Ed | inactive | ON | defrost ended by timeout | [dil[dt][c14][A8] |
dF | inactive | ON | defrost running | [d6=0] |
cht | inactive | ON | condenser dirty pre-alarm | [A4=10] |
CHT | active | ON | condenser dirty alarm | [A4=10] |
EtC | inactive | ON | dock alarm |
Dixell XR02CX XR03CX XR06CX
1. Microcomputer panel
sketch map, meanings of running indicator light and LED shows.
2. SET To display the target set point, in programming mode it selects a
parameter or confirms an operation.
To start a manual defrost。
In programming mode, it browses the parameter codes or increases the displayed
value.
In programming mode, it browses the parameter codes or decreases the displayed
value.
To lock or unlock the keyboard
To enter in programming mode
To return to room temperature display
3. How to see the point.
Push and immediately release the SET key, the set point will be shown; Push
and immediately release the SET key or wait for about 5s to return to normal
visualization.
4. How to change the setpoint.
Push the SET key for more than 2 seconds to change the Setpoint value;
The value of the set point will be displayed and the “°C” or “°F” LED starts
blinking;
To change the Set value push the arrows.
To memorize the new set point value push the SET key again or wait for 10s.
5. How to start a manual defrost.
Push the DEF key for more than 2 seconds and a manual defrost will start.
LED | MODE | SIGNIFICATO |
---|---|---|
On | Compressor enabled | |
Flashing | Anti-short cycle delay enabled (AC parameter) | |
On | Defrost in progress | |
Flashing | Dripping in progress | |
On | Fans output enabled | |
Flashing | Fans delay after defrosting |
| On| Measurement unit
Flashing| Programming mode
| On| Measurement unit
Flashing| Programming mode
6. How to change a parameter value
To change the parameter’s value operate as follows:
Enter the Programming mode by pressing the keys for 3s (“°C” or “°F” LED
starts blinking).
Select the required parameter. Press the “SET” key to display its value
Use to change its value.
Press to store the new value and move to the following parameter. Press “SET”
to store the new value and move to the following parameter. To exit: Press or
wait 15s without pressing a key.
NOTE: the set value is stored even when the procedure is exited by
waiting for the time-out to expire.
7. To lock the keyboard.
Keep pressing for more than 3s the keys. The “OF” message will be displayed
and the keyboard will be locked.
If a key is pressed more than 3s the “OF” message will be displayed. If a key
is pressed more than 3s the “OF” message will be displayed.
8.To unlock the keyboard.
Keep pressed together for more than 3s the keys till the “on” message will be
displayed .
9. Alarm signaling.
Mess. | Cause | Outputs |
---|---|---|
“P1” | Room probe failure | Compressor output according to “Cy” e “Cn” |
“P2” | Evaporator probe failure | Defrost end is timed |
“HA” | Maximum temperature alarm | Outputs unchanged |
“LA” | Minimum temperature alarm | Outputs unchanged |
“EA” | External alarm | Outputs unchanged |
“CA” | Serious external alarm | All outputs OFF |
“dA” | Door Open | The compressor and fans restart |
Our products have been modified precisely before leaving factory, so to avoid
damaging compressor unit or other malfunctions, users mustn’t modify the
microcomputer
parameters privately.
Technical Parameters
Product (EN)| lemon| Rated
voltage| Rated power (W)| Current (A)| Volume (L)| Safety climate class|
Refrigerant| (6)Town| LED Lamp (W)| Dimension D x W x H (mm)| The net volume
(L)| Energy consumption over 24hours (E24h)| Annual energy consumption (AEC)|
Energy efficiency index (EEI)
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
iazaaij| HED236| 220-240V, 50Hz| 600| 3| 670| 4, 5| R290| 120| 3| 730 x 805 x
2065| 455| 5.| 1821| 49
HED238| 220-240V, 50Hz| 980| 5.| 1240| 4, 5| R290| 150| 3| 1314 x 805 x 2065|
940| 8.| 2989| 49
Refrigerator| HED235| 220-240V, 50Hz| 220| 1.| 670| 4, 5| R600a| 110| 3| 730 x
805 x 2065| 455| 1.| 460| 34
HED237| 220-240V, 50Hz| 350| 2.| 1240| 4, 5| R600a| 140| 3| 1314 x 805 x 2065|
940| 2.| 734| 34
NOTES :If the technical data has any changes, we will not notify you any longer.
OFFICIAL APPROVAL AND RULES
Our products full fill the present E.U. rules, including the CE mark of the
European official approval
The latest version of the following directives and standards
2006/42/EC
2012/19/EU
EN 60335-1
EN 62233
EN 62233
EN 61000-3-2
EN 55014-2| 2014/30/EU
2011/65/EU
EN 60335-2-89
EN 55014-1
EN 55014-1
EN 61000-3-3
---|---
CORRECT DISPOSAL OF THIS PRODUCT
This marking indicates that this product should not be disposed of with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.
W081155801
version number 20201020
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>