FTHW Wall-Mounted Gas Condensing Heating Only Boiler User Manual

June 5, 2024
FTHW

FTHW Wall-Mounted Gas Condensing Heating Only Boiler

FTHW Wall-Mounted Gas Condensing Heating Only Boiler FIG
1

FOR YOUR SAFETY : This product must be installed and serviced by a professional service technician, qualified in hot water boiler and heater installation and maintenance. Improper installation and/or operation could create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death. Improper installation and/or operation will void the warranty.

WARNING
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a nearby phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or gas supplier.

Familiarizing yourself to THE FT

FTHW Wall-Mounted Gas Condensing
Heating Only Boiler FIG 2

Heating Only Boiler

The FT is a highly efficient, wall mounted, condensing and fully modulating, residential boiler. This Users Manual will guide you into the basics of operating your FT
Please reference the Installation and Operation Manual for complete details. Doc # 1342

NO Name of Component
1 Air Vent (air eliminator)
2 Air Intake Collar
3 Air / Gas Mixing Pipe
4 Gas Inlet Pipe 2
5 Gas Valve
6 Exhaust Duct
7 Low Water Temperature Sensor
8 OP Sensor
9 Flame Detecting Sensor
10 Main PCB
11 Control Display
12 Manual ON/OFF Power Switch
13 Gas Inlet Pipe 1
14 ‘CH’ Internal Pump
15 Gas Inlet Adapter
16 ‘CH’ Supply Adapter
NO Name of Component
17 CH Pressure Gauge
18 ‘CH’ Return Adapter
19 Condensate Trap
20 Condensate Adapter
21 CH Return Temperature Sensor
22 Condensate Air Pressure Switch
23 Terminal Block
24 Heat Exchanger
25 Ignition Transformer
26 Sight Glass
27 Burner Overheat Switch
28 Igniter
29 BLDC Fan (blower)
30 Exhaust Temperature Sensor
31 Air Pressure Sensor
32 Vent Pipe Collar

The FT, Heating Only, BoilerFTHW Wall-Mounted Gas Condensing Heating Only
Boiler FIG 3

Shown is the FT Heating Only 140 MBH.
All sizes are very similar in component layout.

Caring For Your FT

Your FT will require very little maintenance.
However, as with any fine appliance there are certain steps that should be taken to ensure continuing optimum performance.

General Care
Keep the area around the FT clean and free from combustible materials, gasoline and other flammable liquids and vapors.
The FT must be completely isolated and protected from any source of corrosive chemical fumes such as trichlorethylene, perchlorethylene, chlorine, etc.
Keep bottom and top openings on the boiler free for proper ventilation of interior components.
Do not obstruct or block a free flow of air to the boiler to ensure proper ventilation.
If desired, clean the jacket surfaces with a damp cloth and mild detergent. Do not use flammable cleaning materials.
If sidewall vented, keep the vent terminal clear of obstructions — do not allow snow to cover the vent terminal. Clean the intake screen often, and then develop an appropriate maintenance schedule.

Annual Inspection of Flue and Vents
Visually inspect the vent pipe once a year. Should any deterioration exist, have the affected parts replaced by a qualified service person.

In the Event of a Power Failure
The FT can not be operated during an electrical power outage. If there is an extended power outage with danger from freezing, then the FT (and all other water systems) should be drained completely. When draining the boiler, turn off main electrical disconnect switch. When placing back in service, refer to Section 3 of this Manual for instruction. All draining and filling must only be done by a qualified service person.

Full Service Every Year
In addition to the annual visual inspections, a qualified service agency should conduct a detailed inspection of all flue product carrying areas of the boiler and its venting system.

Shutting Down the FT

  1. Turn off the main electrical disconnect switch.
  2. Close all manual gas valves.
  3. If freezing is anticipated, drain the FT and be sure to also protect building piping from freezing. All water must be removed from heat exchanger and condensate trap or else damage from freezing may occur. Please refer to the Install and Operating Manual.
    This step to be performed by a qualified service person.

The Control Display and Operation

FTHW Wall-Mounted Gas Condensing
Heating Only Boiler FIG 4

The Control Display has a Control Dial (E), 4 buttons (A, B, C, D), and a Liquid Crystal Display (with 72 back-lit segments). This section of this manual gives instruction on how to navigate into the many functions of the FT and to change temperature set points, set system variables and controller parameters.

Buttons Functionality
PRESS (Tap) PRESS and HOLD (5 seconds)

A

| |

Display Power

| Turns Control Display ON/OFF|

B

| |

Modes

|

Tap to return to menu

| (If Display Power was On ) Status Display Mode

(If Display Power was Off ) Installer Mode

C

| | Heating Water| CH set-point change mode (Maxium 82°C(180°F))|

D

| | Time / Date Set|

No Change

|

To SET: Year/Month/Week/Day/Time/Min

E

| |

Scroll / Select

| Menu select or value up(+)/down(-) or setting dial.|

Temperature Specifi cations
Operating ambient Temperature Range : -10 to 60°C. Operating Relative Humidity up to: 90% at 40°C. Shipping & Storage Temperature Range of : -20 to 80°C.

The Control Display and Operation (continued)FTHW Wall-Mounted Gas
Condensing Heating Only Boiler FIG 5

Symbol Name Description
**** Service Reminder mode Service Reminder mode indication
**** Outside Temperature Mode Outside Temp setting indication
**** Anti-freeze mode Anti-freeze mode indication
**** Storage mode Storage mode indication
**** Information mode Information mode indication
**** Communication state Communication state indication
**** Time setting mode Time /Dispaly/Install mode indication
**** Fan operating mode Fan operating mode indication
**** Flame signal Flame Signal indication
**** CH pump mode CH pump mode indication
**** Storage pump mode Storage pump mode indication
**** Internal recirculation mode Internal recirculation mode indication
**** Celsius mode Indicated as Celsius temperature
**** Fahrenheit mode Indicated as Fahrenheit temperature
**** Heat demand mode Heat demand mode indication
**** DAY mode Current day mode indication
**** Cascade System connecting mode Cascade System connecting mode

indication
****| Cascade System operating mode| Cascade System operating mode indication

Operating Mode
After the Power is turned on, and/or the Control Display is turned on , the Control Display will go through a ‘Start Up’ checklist and briefl y show a sequence of diagnostic codes before entering into the ‘Operating Mode. It will then display the following information. FTHW Wall-Mounted Gas Condensing
Heating Only Boiler FIG 6

Indicate Indicator

Current Operating Temperature Set-Point

|
If the Fan is operating|
If a flame is detected|
Celsius or Fahrenheit| or
Date and Time indicator|
If Outside Temperature Sensor is operating|
If there is a Demand for Central Heat (CH)|
If CH pump state is operating|
If Internal recirculation pump is operating|
If Communication state is activated|

The Control Display can operate through user and service modes that have and dedicated controls:

  • Set-point change mode
  • Lock mode • Error mode
  • Status display mode
  • Outside Temperature mode
  • Installer mode

Control Display will not allow changing of button in case of lock mode activated.FTHW Wall-Mounted Gas Condensing Heating Only Boiler FIG
7

Setting the Clock

The P-950EH Control Display does NOT have a daily timer or programmable thermostat. Setting the Clock

  1. Press and hold the‘Clock button’ for about 5 seconds. Set the ‘Year’ by turning the dial E. And then, press the dial E to Save.
  2. Set the ‘MON’ (Month) by turning the dial E to the desired month number. Then press the dial E to Save.
  3. Set the ‘DATE’ (1-31, Day of the Month) by turning the dial E. Then press the dial E to Save.
  4. Set the ‘HOUR’ (1-24, Hour of the Day) by turning the dial E. Then press the dial E to Save.
  5. Set the ‘MIN’ (1-60, Minute of the Hour) by turning the dial E. Then press the dial E to Save.
  6. Set the ‘Day’ (Sun – Sat) by turning the dial E. Then press the dial E to Save.

To Exit at any time, press and hold the ‘Clock button’ for about 5 seconds. FTHW Wall-Mounted Gas Condensing Heating Only Boiler FIG
8

To change CH Setpoint, press the C button. The CH Icon and current CH Setpoint will fl ash.

  • Turn the E dial clockwise to increase, and counterclockwise to decrease CH setpoint, until desired temperature is reached.
    Press E dial to save changes and to Exit.
Indicate Indicator
Current CH Temperature Set-Point
Celsius or Fahrenheit or
If Communication state is activated
If flame is detected
Date and Time indicator
If CH pump is operating
If there currently a Demand for Central Heat (CH)
  • The Default CH set-point is 180°F (82°C)
  • CH set-point range is 86°F ~180°F (30.0°C ~ 82.0°C)

To change any Status Parameter,
Press and Hold Button B to get into the Status Display Mode.
Rotate Dial E until you fi nd the Parameter that you wish to change. Tap Dial E to enter that Parameter. Adjust to the setting that you require and then press (tap) Dial E to save and to Exit.

Digital Display Status Display Parameter Description
O: ot Outdoor temperature Current outdoor sensor temperature
A: In 0-10 V display Current voltage of (0-10V input)
b: tt CH target temperature in cascade system Current CH target

temperature or Current System target temperature in a cascade system
C: It| CH return water temperature| Current CH return water temperature
d: Fr| FAN speed ( rpm)| Current FAN speed ( RPM)
E: oP| CH supply temperature (Operating temperature)| Current heating temperature
F: Eh| Exhaust gas temperature| Current exhaust gas temperature

H: dH

| Indirect DHW tank temperature

  • If temperature sensor is not connected then it will display with 0°F (0°C).

|

Current DHW tank temperature

I: oH| Overheat water temperature| Current Overheat water temperature

L: rt

| 1: PH|

Burner Operation Time

| Time for supply power|

L: rt on display on sub menu

| Unit : 1000hour
2: rh| Time for burner

operation

| Unit : 1hour
3: rH| Time for burner

operation

| Unit : 1,000hour
4: It| Cycle for ignition| Cycle : 10 times the displayed unit
5: IH| Cycle for ignition| Cycle : 10,000 times the displayed unit

M: CC

| SELF| Percentage of self units running.| Percentage of self units running.

ALL

|

Capacity for all operating cascade units

| Percentage of all cascade units running.

This screen shows the overal cascade power output. The range of this value of boilers communicating with theMaster x 100. For example, if 8 boilers are connected and communicating, the maximum cascade power is 800%.

Range: 0-100%

F1 – F 19| Capacity for individual boilers| Percentage of each cascade units running. Ex. F1, F2, ….

N: St

| System Temperature (cascade mode) * If system temperature sensor is not connected then it will display with 0°F (0°C).|

Current System Temperature (cascade mode)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>