SOEHNLE 68122 Airfresh Clean 400 Air Purifier
Safety instructions
- Before commissioning, check that the voltage specification corresponds to the local mains voltage.
- This device may only be used by children 8 years of age and older and by persons with limited physical, sensory or mental abilities or lack of experience and knowledge if they have been supervised or instructed in the safe use of the device and understand the resulting hazards.
- Cleaning and maintenance of the appliance must not be carried out by children without supervision.
- Children are not allowed to play with the device.
- Always turn off the appliance and unplug the power cord from the outlet before moving or transporting the appliance.
- Do not operate the device with a defective mains plug or mains cable.
- Do not spray flammable materials, such as insect poisons or fragrances around the Airfresh Clean 400.
- Make sure that the air inlet and outlet are not covered.
- Do not insert any objects into the air inlet of the unit. It may damage the device or cause injury.
- Do not use or store the product where it may fall into a bathtub, sink, water or other liquid.
- Do not reach for a device that has fallen into water or other liquid.
- Do not reach into water or other liquids, even if the unit is not connected at this time.
- If damp, there is a risk of electric shock when the unit is reconnected to the wall outlet.
- Wipe off moisture with a dry cloth.
- Do not touch the plug or device with wet hands.
- The filter has to be changed, do not unscrew the device beyond that.
- In particular, replacement of the UVC lamp by the user is not permitted.
Caution
- If the power outlet used to operate the Airfresh Clean 400 is not properly connected, the appliance’s plug will become hot. Make sure that you are using a properly connected power outlet for the device.
- Do not place any objects on the Airfresh Clean 400 and do not sit or stand on it.
- Only use the original Soehnle filter, which is specially designed for this Airfresh Clean 400.
- Do not use the Airfresh Clean 400 after using incense as an insect repellent or in places where oil residues, chemical vapours or incense sticks are present.
- Do not use the Airfresh Clean 400 near heaters, open fireplaces or gaspowered devices.
Scope of delivery
- 1x Soehnle Airfresh Clean 400
- 1x Soehnle HEPA combination filter
- For Airfresh Clean 400 1x instruction manual
Device description
- A : control console.
- B : air outlet.
- C : PM 2.5 Sensor fine dust sensor)Mwith protective flap.
- D : Housing and air inlet.
- E : UVC lamp.
- F : Soehnle HEPA combination filter 68129.
- G : removable case back.
- H : screw cap.
Intended Use
The Airfresh Clean 400 is used exclusively for cleaning the room air.
Air purification
With the Soehnle HEPA combi filter you can remove a large number of unwanted particles and odours from the room air. Microorganisms and viruses are destroyed by switching on the UVC light.
Pre filter
Captures coarse dust.
Soehnle HEPA combination filter
A HEPA filter detects dust, smoke, pollen and other allergens. An activated carbon filter filters odours from the air. UV-C light: Destroys microorganisms such as germs, viruses, bacteria, fungal spores and mould toxins mycotoxins.
Before first use
- Place the unit upright on a firm, level surface.
- Maintain a minimum distance of half a meter from the unit to each wall.
- To ensure optimum performance of the unit, ensure that the air inlets and outlets are not blocked.
- Check the power cord to make sure it is free of damage.
- Turn and open the underside of the unit as described in Chapter 8. Remove and unpack the Soehnle HEPA combi filter.
- Then insert the unpacked filter again, close the device again and turn it over again.
- Wait until the device has reached room temperature approx. 2 hours.
- Connect the power cord to a wall outlet.
Daily use and operation
PM 2,5 sensor and LED ring
The current air quality is continuously determined by Airfresh Clean 400 in
the form of the PM 2.5 value. The PM 2.5 value is the fine dust load 50% of
particles approx. 2.5μm in μg/m3.
The illuminated LED ring on the upper side indicates the current level of fine
dust pollution caused by different colours
- RED = high load (>50 µg/m³)
- PINK = medium load (20 50 µg/m³)
- LILA = low load (10 20 µg/m³)
- BLUE = no load (0 10 µg/m³)
Please remove the protective flap in front of the PM2.5 sensor C only in an emergency. Please do not allow any objects or other foreign bodies to come into contact with the sensor.
Switching on and off
Press the ON/OFF button (L) to turn the Airfresh Clean 400 on or off. The
ON/OFF control lamp lights up.
First press
Device is switched on
Press twice
Activates the automatic mode
Press the third time
Deactivates the automatic mode.
Press four times
Device is switched off
The control lamps light up accordingly.
Automatic mode
By pressing the (L) button as described above, the Airfresh Clean 400 is also set to automatic mode. In this mode, the unit automatically adjusts the fan speed in relation to the air quality in the room. This ensures you always get the best possible air quality. The control lamp for AUTO lights up.
Setting the operating time
Press button I to set the desired operating time. Choose between 2, 4 and 8 hours. The control lamp lights up accordingly. The device switches off automatically after the time has elapsed. If no operating time has been selected no indicator light is lit, the Airfresh Clean 400 runs in continuous operation.
Changing the fan speed
Press button (K) to select the fan speed and thus the desired intensity of air discharge: Low (I) – Medium (II) – High (III) – Turbo all indicator lights on
UV-C lamp and night mode
Press button J once to switch on the UVC lamp inside the Airfresh Clean 400
UVC control lamp lights up). Press again to activate the night mode without
switching off the UVC lamp (UVC control lamp lights up, NIGHT control lamp
flashes). By further pressing button J you can switch off the UVC lamp (UVC
control lamp is off, NIGHT control lamp flashes) or switch both off (UVC
control lamp is off, NIGHT control lamp is off .
Night mode
In night mode, you can run the Airfresh Clean 400 without being disturbed by
additional light sources. If you activate the night mode, all indicator lights
on the device are switched off after 10 seconds without the device being
switched off. Previously made settings for operating time and fan speed are
retained. The activation of the night mode is initiated by a flashing of the
control lamp before the lighting is switched off completely. The device can
run either in night mode or in automatic mode. These two modes cannot be
activated at the same time.Active Restart Function Enables operation via a
controllable socket or timer. If the power supply is interrupted, the device
remembers all settings and continues to run automatically with the same
settings as soon as the power supply is restored.
Cleaning and care
Cleaning the combination filter
Regular cleaning of the combination filter once a month guarantees troublefree operation of the Airfresh Clean 400 and maximum indoor air quality. Proceed as follows
- Switch off the device before each cleaning and unplug the mains plug.
- Turn the unit upside down and place it on a firm surface 2.1.
- Open the screw cap on the bottom of the unit 2.2.
- Lift off the bottom of the housing 2.3.
- Remove the Soehnle HEPA combi filter 2.4 and clean it.
- The prefilter is attached to the filter with Velcro.
- Clean the prefilter under running water.
- Make sure the prefilter is dry before reattaching it to the Soehnle HEPA combi filter.
- The Soehnle HEPA combination filter should only be cleaned with a vacuum cleaner.
- Reinsert the filter and make sure it is properly inserted.
- Close the device 3 and tighten the screw cap.
- Turn the device back the right way round and place it on a firm surface.
- Make sure that the base plate is correctly inserted and locked into the locking guide.
- Also note the arrow marking on the opposite side of the bottom gap 3.
- This closes the plate airtight with the bodies.
- Reconnect the power cord to a wall outlet and turn on the power.
Cleaning the housing
Switch off the device before each cleaning and unplug the mains plug. Clean the housing of the Airfresh Clean 400 with a slightly moistened cloth.
Replacing the filter
The combination filter should be replaced by a new one after approx. 4320 operating hours. After approximately 4320 operating hours, the ON/OFF indicator light on the instrument’s control panel flashes to indicate the recommended filter change. Only use original Soehnle filters! To change the filter, proceed as follows
- Switch off the appliance and unplug it from the mains supply.
- Open the unit as described in chapter 8 and remove the Soehnle HEPA combi filter (2.4).
- Now insert the new Soehnle HEPA combination filter into the housing.
- Make sure that the new filter unit is inserted correctly.
- Close the device and tighten the screw cap. Please make sure that the device is properly closed .
- Turn the device back the right way round and place it on a firm surface.
- Reconnect the power cord to a wall outlet and turn on the power.
- Press the ON/OFF button (L) for 5 seconds.
- The filter time is reset.
Transport and storage
Transport
WARNING
Always switch off the device before transport. Always unplug the power cord
from the outlet.
Storage
We recommend that you carefully clean your Airfresh Clean 400 before storing it. Please make sure that all parts are clean and dry before storage. Store the Airfresh Clean 400 in a cool, dry place.
Troubleshooting
Before performing any of the following tests, turn off the power and unplug the appliance.
PROBLEM
The device does not work
- Check that the Airfresh Clean 400 is connected to a power source.
- Check that a filter is inserted and correctly positioned.
- Check that the bottom cover is correctly seated and firmly closed with the screw cap
Insufficient airflow
- Check that the filter is clean. If dirty, clean it.
- Check that the air inlets and outlets are not blocked or obstructed.
Excessive noise
- Check whether there are any foreign objects in the fan and remove them if necessary by turning the unit upside down.
- Check that the filter is clean.
- If dirty, clean it.
- Check that the filter is seated correctly.
- Check that the unit is standing securely and straight on a firm surface.
Device shows constantly high values
Reset the sensor: Switch on the device. Press the ON/OFF button (L) for 5 seconds and let the unit run for 25 hours (depending on room size). The device indicates by flashing the two control lamps ON/OFF and AUTO as soon as the sensor has been reset.
Spare and wear parts
68129 Soehnle HEPA Combifilter Prefilter, HEPA Filter & Activated Carbon Filter Further spare parts can be ordered directly from us. Please contact our customer service department.
Soehnle Customer Service
For questions and suggestions please contact our consumer service. Contact possibilities and further information on our products can be found at www.soehnle.com
Declaration of conformity
Products marked with this symbol comply with applicable European directives. The EU Declaration of Conformity can be found under www.soehnle.com.
Disposal of used electrical products
Please do not dispose of the device in the household waste. Should you need to dispose of your appliance, it should first be rendered unusable (e.g. by cutting off the cord and the plug) and then disposed of in accordance with current regulations. Your local authority will be able to provide youwith the necessary information. Dispose of packaging appropriately.
Warranty
Leifheit AG grants you a 2year warranty on this quality product from the date
of purchase (or, in the case of orders, from the date of receipt of the goods.
The warranty claims must be asserted immediately after the occurrence of the
defect within the warranty period. The warranty extends to the quality of the
products. Excluded from the warranty are
- Wear and tear caused by use or other natural causes,
- Damage due to improper use or handling e.g. B. shock, impact, fall.
- Damage caused by nonobservance of the specified operating instructions.
- In the event of a warranty claim, Leifheit will either repair defective parts or replace the product at its own discretion.
- If a repair cannot be carried out and an identical product is no longer available in the assortment for the purpose of replacement, you will receive a replacement product that is as similar as possible.
- A refund of the purchase price is not possible in case of warranty.
- Furthermore, this warranty does not grant any claims for damages.
- To make a warranty claim, please contact the dealer from whom you purchased the product by presenting the defective product and the proof of purchase copy.
- This warranty is valid worldwide.
- Your statutory rights, in particular warranty rights, continue to apply to you and are not limited by this warranty.
Technical data
Technical data
Article number| 68122
Room size up to| 38 m2
Working environment| 5 °C ~ 40 °C, 10 ~ 95 % RH
operating voltage range| 220 – 240 V~ Alternating current
current frequency| 50 / 60Hz
Rated power of the system| 6 W [±20%] (I), 7 W [±20%] (II), 10 W
[±15%] (III), 26 W [±10%] (Turbo)
Dimensions| 231 (Ø) x 391 (H) mm
Volume| ≤30 dB (I), ≤37 dB (II), ≤47 dB (III), ≤60 dB (Turbo)
Weight| 2.8 kg
UV light Wavelength| 254 nm
Service life of the UV-C lamp| approx. 15,000 hours
The product is double insulated and corresponding to protect class 2
I = Fan stage 1
(III) = Fan stage 3 and corresponds
(II) = Fan stage 2 (Turbo) = Fan stage 4
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>