Garland G36-6S Natural Gas 6 Burner 36 Inch Range Instruction Manual
- June 4, 2024
- GARLAND
Table of Contents
G36-6S Natural Gas 6 Burner 36 Inch Range
Instruction Manual
INSTALLATION AND OPERATION MANUAL All 24, 36, 48, & 60-inch wide models .
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE, OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY, OR DEATH. READ THE INSTALLATION, OPERATING, AND
MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
EQUIPMENT
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE, OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY, OR DEATH. READ THE INSTALLATION, OPERATING, AND
MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
EQUIPMENT
Users are cautioned that maintenance and repairs must be performed by a
Garland authorized service agent using genuine Garland replacement parts.
Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with
national and local codes or installation instructions provided with the
product, or any product that has its serial number defaced, obliterated or
removed, or which has been modified or repaired using unauthorized parts or by
unauthorized service agents. For a list of authorized service agents, please
refer to the Garland website at http://www.garland-group.com. The
information contained herein, (including design and parts specifications), may
be superseded and is subject to change without notice.
IMPORTANT INFORMATION
WARNING:
This product contains chemicals known to the state of California to cause
cancer and/or birth defects or other reproductive harm. Installation and
servicing of this product could expose you to airborne particles of glass
wool/ceramic fibers. Inhalation of airborne particles of glass wool/ceramic
fibers is known to the state of California to cause cancer. Operation of this
product could expose you to carbon monoxide if not adjusted properly.
Inhalation of carbon monoxide is known to the state of California to cause
birth defects or other reproductive harm.
Keep appliance area free and clear of combustibles.
DIMENSIONS AND SPECIFICATIONS
Clearances Applicable For All Models
Surface| Sides| Rear
Combustible Wall Minimum| 14″ (356mm)| 6″ (152mm)
Non-Combustible Wall Minimum| 0″| 0″
Gas Pressures
Gas| Minimum Supply Pressure| Manifold Operating
Pressure
---|---|---
Natural| 7″ WC (17.5 bar)| 4.5″ WC (11.25 mbar)
Propane| 11″ WC (28 mbar)| 10″ WC (25 mbar)
Gas Inlet Size
Model Width | Connection |
---|---|
24″ (610mm) & 36″ (914mm) | 3/4″ NPT Rear Gas Connection |
48″ (1219mm) & 60″ (1524mm) | 1″ NPTRear Gas Connection |
Individual Burner Input Rates
Burner
| Input BTU/HR
---|---
Natural Gas| Propane Gas
Open Top| 33,000| 26,000
Hot Top Burner (In lieu of 2 open top burners)| 18,000| 18,000
Griddle Burner (In lieu of 2 open top burners)| 18,000| 18,000
Raised Griddle Broiler (Consists of 3 burners)| 33,000| 33,000
Oven Burner For Full Size Standard or Convection Oven| 38,000| 32,000
Space Saver Oven| 32,000| 28,000
Rates are for installations up to 2000’ (610m) above sea level
Base Model Designations & Total Input Rates
**Model #** | **Description** | Input BTU/Hr |
---|---|---|
Natural Gas | Propane Gas | |
G24-4S | 24″ (610mm) nominal size unit, 4 open burners, storage base | 132,000 |
104,000
G24-4T| 24″ (610mm) nominal size unit, 4 open burners, modular top.| 132,000|
104,000
G24-4L| 24″ (610mm) nominal size unit, 4 open burners, space saver oven|
164,000| 132,000
G36-6S| 36″ (914mm) nominal size unit, 6 open burners, storage base| 198,000|
156,000
G36-6T| 36″ (610mm) nominal size unit, 6 open burners, modular top.| 198,000|
156,000
G36-6R| 36″ (914mm) nominal size unit, 6 open burners, standard oven| 236,000|
188,000
G36-6C| 36″ (914mm) nominal size unit, 6 open burners, convection oven|
236,000| 188,000
G48-8SS| 48″ (1219mm) nominal size unit, 8 open burners, storage base|
264,000| 208,000
G48-8RS| 48″ (1219mm) nominal size unit, 8 open burners, standard oven,
storage base| 302,000| 240,000
G48-8CS| 48″ (1219mm) nominal size unit, 8 open burners, convection oven,
storage base| 302,000| 240,000
G48-8LL| 48″ (1219mm) nominal size unit, 8 open burners, 2 space saver ovens|
328,000| 264,000
G60-10SS| 60″ (1524mm) nominal size unit, 10 open burners, storage base|
330,000| 260,000
G60-10RS| 60″ (1524mm) nominal size unit, 10 open burners, standard oven,
storage base| 368,000| 292,000
G60-10CS| 60″ (1524mm) nominal size unit, 10 open burners, convection oven,
storage base| 368,000| 292,000
G60-10CR| 60″ (1524mm) nominal size unit, 10 open burners, standard oven,
convection oven| 406,000| 324,000
G60-10RR| 60″ (1524mm) nominal size unit, 10 open burners, 2 standard ovens|
406,000| 324,000
G60-10CC| 60″ (1524mm) nominal size unit, 10 open burners, 2 convection ovens|
406,000| 324,000
G60-6R24SS| 60″ (1524mm) nominal size unit, 6 open burners, 24″ (610mm) raised
griddle/broiler, storage base| 231,000| 189,000
G60-6R24RS| 60″ (1524mm) nominal size unit, 6 open burners, 24″ (610mm) raised
griddle/broiler, standard oven, storage base| 269,000| 221,000
G60-6R24CS| 60″ (1524mm) nominal size unit, 6 open burners, 24″ (610mm) raised
griddle/broiler, convection oven, storage base| 269,000| 221,000
G60-6R24CR| 60″ (1524mm) nominal size unit, 6 open burners, 24″ (610mm) raised
griddle/broiler, standard oven, convection oven| 307,000| 253,000
G60-6R24RR| 60″ (1524mm) nominal size unit, 6 open burners, 24″ (610mm) raised
griddle/broiler, 2 standard ovens| 307,000| 253,000
G60-6R24CC| 60″ (1524mm) nominal size unit, 6 open burners, 24″ (610mm) raised
griddle/broiler, standard oven, 2 convection ovens| 307,000| 253,000
INTRODUCTION
- Check the crate for possible damage sustained during transit . Carefully remove the unit from the crate and again check for damage. Any damage to the appliance must be reported to the carrier immediately .
- The wires for retaining packing material must be removed from units. Any protective material covering stainless steel parts must also be removed.
- All equipment is supplied with 6” (152mm) legs unless specified to be a dais for cove base mounting, casters, or deck mount flanged feet . Units 48” (1219mm) and 60” (1524mm) wide have legs factory mounted. Base mounting is required when the range is being installed on a combustible floor .
- The type of gas and supply pressure that the equipment was set up for at the factory is noted on the rating plate and on the packaging. This type of gas supply must be used
- Do not remove permanently affixed labels, warnings or rating plates from the appliance, for this may invalidate the manufacturer’s warranty.
Rating Plate
All burner input rates are shown on the rating plate, which is located behind
the lower front drop-down panel under the oven door.
INSTALLATION
This product has been certified as commercial cooking equipment and must be
installed by professional personnel as specified. THIS APPLIANCE IS NOT
RECOMMENDED FOR RESIDENTIAL INSTALLATION.
We suggest installation, maintenance and repairs should be performed by your
local Garland/US Range authorized service agency.
Siting
The floor on which the appliance is to be sited must be capable of adequately
supporting the weight of the appliance and any ancillary equipment. Units with
ovens must be fitted with legs if installed on a combustible floor . Adequate
clearance must be provided for servicing and proper operation.
Appliances Equipped With Casters
- The installation shall be made with a connector that complies with the Standard for Connectors for Moveable Gas Appliances, ANSI Z21 .69/CSA 6 .16, Addenda Z21 .69B-2006/CSA 6 .16B-2006 (or latest edition), and a quick-disconnect device that complies with the Standard for Quick Disconnects for Use with Gas Fuel, ANSI Z21 .41/ CSA 6 .9, Addenda Z21 .41A-2005/CSA 6 .16A-2005 (or latest edition)
- The front casters of the appliance are equipped with brakes to limit the movement of the appliance without placing any strain on the connector or quick disconnect device or its associated piping.
- Please be aware; the required restraint is attached to a cutout hole in the side panel, and if disconnection of the restraint is necessary, be sure to reconnect the device after the appliance has been returned to its original position .
Appliances Equipped With Legs
- Raise the front of the appliance and block. Do not lay the appliance on its back .
- Legs are threaded to be easily screwed into the holes provided at the bottom of the range.
- Once legs have been attached and secured they can be adjusted to level the appliance and compensate for uneven flooring.
Installing Shelf To Backguard
Note: Shelf may be installed before or after installing the backyard to the
range.
- Loosen 4 bolts on the front of the backyard approximately 1/4” (6mm).
- Align the 4 slotted holes on the back of the shelf with the 4 bolts on the backguard.
- Slide the shelf downward until the 4 bolts are engaged in the slotted portion of the keyhole.
- Tighten the 4 bolts to secure the shelf.
- On 60” units only, install a sheet metal screw through the hole in the underside of the shelf into the backyard and tighten.
Backguard With High Shelf, Salamander Or Cheesemelters Mounting Instructions
- The rear of the range must be easily accessible.
- Please refer to the installation instructions included with the salamander or cheese melter for further instructions on these units.
- For the backyard or high shelf, place on the rear of the range, slipping the support brackets into the openings in the main body sides.
- Securely fasten the support brackets to the burner box sides with (4) sheet metal screws provided.
Ventilation Air
The following notes are intended to give general guidance. For detailed
recommendations, refer to the applicable code(s) in the country of destination
. Proper ventilation is critical for optimum performance. The ideal method of
ventilating open-top equipment is the use of a properly designed canopy that
should extend six inches (152 mm), beyond all sides of the appliance(s) and
six feet, six inches (1981mm) above the floor .
A strong exhaust will create a vacuum in the room. For an exhaust vent to work
properly, replacement air must be equal to the amount of air exhausted. An
imbalance between the exhaust and replacement air can cause degradation in the
appliance’s performance.
All gas burners and pilots need sufficient air to operate. Large objects
should not be placed in front of the appliance(s) that would obstruct the flow
of air into the front.
Statutory Regulations
The installation of this appliance must be carried out by a competent person
and in accordance with the relevant regulations, codes of practice, and the
related publications of
the country of destination .
The installation must conform to the National Fuel Gas Code ANSI Z223 .1, or
latest edition, NFPA No .54 – latest edition/or local code to assure safe and
efficient operation. In Canada, the installation must comply with CSA B149 .1
and local codes .
Gas Connection
The local gas authority should be consulted at the installation planning stage
in order to establish the availability of an adequate supply of gas and to
ensure that the meter is adequate for the required flow rate. The pipework
from the meter to the appliance must be an appropriate size . All fixed (non-
mobile) appliances MUST be fitted with an accessible upstream gas shut-off
valve as a means of isolating the appliance for emergency shut-off and for
servicing. A union or similar means of disconnection must be provided between
the gas-cock and the appliance.
A manually operable valve must be fitted to the gas supply to the kitchen to
enable it to be isolated in an emergency . Wherever practical, this shall be
located either outside the
kitchen or near to an exit in a readily accessible position . Where it is not
practical to do this, an automatic isolation valve system shall be fitted
which can be operated from a readily accessible position near to the exit . In
locations where the manual isolation valve is fitted or the automatic system
can be reset this notice MUST be posted:
“ALL DOWNSTREAM BURNER AND PILOT VALVES MUST BE TURNED OFF PRIOR TO ATTEMPTING
TO RESTORE THE SUPPLY. AFTER EXTENDED SHUT-OFF, PURGE BEFORE RESTORING GAS .”
Electrical Connections (Where Applicable)
IMPORTANT- This appliance must be electrically grounded in accordance
with local codes, or in the absence of local codes with the National
Electrical Code .
220/240 Volt Convection Oven Models
When the appliance is ordered and equipped for 220/240-volt operation, the
supply line must be connected to the wiring terminations located inside the
terminal box at the
the rear of the appliance.
For ease of attaching the supply line, there is a removable cover on the
terminal box .
Permanent connection to the electrical service must comply with local codes,
or in the absence of local codes, with the national electrical code .
Installation Notes
Before assembly and connection, check gas supply.
A . The type of gas for which the unit is equipped is stamped on the data
plate located behind the lower front panel. Connect a unit stamped “NAT” only
to natural gas; connect one stamped “PRO” only to propane gas.
B . If it is a new installation have the gas authorities check meter size and
piping to assure that the unit is supplied with the necessary amount of gas
pressure required to operate the unit.
C . If it is additional or replacement equipment have the gas authorities
check the pressure to make certain that the existing meter and piping will
supply fuel to the unit with no more than 0 .15 Kpa pressure drop.
D . Make certain new piping and connections have been made in a clean manner
and have been purged so that piping compound, chips, etc . will not clog
pilots, valves or burners. Use pipe joint compound approved for natural and
liquefied petroleum gases.
N O TE: Gas pressure should be checked when the unit is installed and all
other equipment on the same line is on. The operating gas pressure must be the
same as that specified
on the rating plate. If necessary, pressure adjustment may be made at the
pressure regulator supplied with the appliance. The appliance and its
individual shut-off valve must be
disconnected from the gas supply piping system during any pressure testing of
that system where pressures are in excess of 1/2 PSIG (3 .45kPa .)
Final Preparation
NOTE: Your new range has a plastic coating to help protect the finish
from scratches during shipping. This protective plastic film should be peeled
off prior to starting the range.
TESTING AND ADJUSTMENT
Testing
All fittings and pipe connections must be tested for leaks. Use approved gas
leak detectors, soap solution, or equivalent, checking over and around all the
fittings and pipe connections. DO NOT USE A FLAME! Accessibility to all gas
lines and fittings requires that valve panel(s) lower front panel(s), and/or
oven rack(s) be removed. It may be necessary to remove, or at least raise and
securely prop griddle(s), hot top(s), and/or top grate(s). All parts removed,
(including fasteners), should be stored safely for reinstallation.
1 . Be sure that all valves and thermostats are in the “OFF” position.
2 . Turn on the main gas supply valve. Light all top-section pilots.
3 . Leak test all valves and fittings as described at the beginning of this
section. Correct any leaks as required and recheck.
4 . Light the oven pilot.
5 . Set the oven thermostat to maximum. Leak test all valves and fittings as
described at the beginning of this section correct any leaks as required and
recheck.
6 . Shut off all valves and set thermostat dials to “OFF” or lowest position.
All units are tested and adjusted at the factory, however, burners and pilots
should be checked upon installation and adjusted if necessary.
CAUTION: Gas will flow to the top section burners even if top section
pilots are not lit, except for thermostat-controlled griddles. Gas will not be
interrupted. It is the responsibility of the operator to confirm the proper
ignition of each burner as it is turned on. Should ignition fail to occur 4
seconds after turning a burner on, turn the burner off, wait 5 minutes, and
try again.
OPERATION
Caution: In the event that a binding malfunction valve or thermostat control
is observed DO NOT light the pilots or continue operation until an authorized
service technician
has inspected the appliance. Failure to do so may result in injury.
Open Top burners
Lighting
- Light pilots adjacent to each burner.
- Turn the valve completely on. The burner flame should be 1/2” (13mm) high, stable and blue in color. It should also impinge on the bottom of a pot placed on the burner grate.
CAUTION: Should burner ignition fail within 4 seconds, turn the burner
valve off and repeat steps 1 through 2 . If ignition continues to fail,
consult your factory-authorized service agency.
Ovens (Standard)
Lighting
-
Lower front kick panel below oven door, raise oven hearth bottom for easy access to oven pilot.
-
Turn the oven control knob (figure 1) to “ ” position and then push in to engage the flow of gas through the safety device to the pilot.
-
If the pilot burner fails to light or does not stay lit, wait 5 minutes and repeat steps 2 through 4 .
-
Replace the hearth and close the kick panel, then turn the oven thermostat to desired cooking temperature.
-
To shut down the main burner turn the control knob (figure 1) to the “ ” position.
Shut Down
If a pilot shut down is required loosen the set screw on the knob and remove
the outer temperature thermostat knob by carefully pulling it off. Then push
in and turn the inner
control knob (figure 2) to the position. The system will disengage within 60
seconds.
Convection Ovens
The forced air range oven consists of a food preparation chamber completely
sealed from the combustion area . This eliminates the possibility of
contamination from flue products and permits an efficient method of
circulating the heated air within the cooking chamber . During the cooking
process in a conventional oven, a vapor barrier and a layer of “cool” air
cover the exposed area of the product. In a forced air oven, the fan pushes
the heated air over and around the product, sweeping away the vapor barrier
and cool air, permitting faster heat penetration. This action permits the use
of lower temperatures and shorter cooking times.
The rule of thumb for determining the cooking temperature is to reduce the set
temperature by approximately 80°F, (28°C), from that which you would set in a
conventional
oven. The product should be checked at a point midway through the time
required in a conventional oven.
Lighting
- Lower front kick panel below oven door.
- Push and hold in the oven thermostat control valve knob (figure 1) and turn it counterclockwise to the ignition position “ ”.
- While holding the knob fully in depress the red igniter button and observe that the pilot flame is lit.
- When the pilot is lit, continue to hold the valve knob fully in for 10 seconds, then release it. If the pilot goes out, wait for five (5) minutes, then repeat steps 2 to 4.
Start-Up
- Set the power switch to the “COOK” position .
- Turn the thermostat to the desired setting.
Cool down
- Turn the oven valve knob to the “ ” position this will prevent the main oven burner from cycling on. (figure 1) .
- Turn the thermostat to its lowest setting.
- Open the oven door.
- Set the power switch to the “COOL DOWN” position.
- Once the oven has cooled turn the power switch off and close the oven door.
Shut Down
-
If a pilot shut down is required loosen the set screw on the knob and remove the outer temperature thermostat knob by carefully pulling it off. Then push in and turn the
inner control knob (figure 2) to the position. The system will disengage within 60 seconds . -
The power switch should be in the off position .
Operating Suggestions
The motor in your range convection oven is maintenance-free since it is
constructed with self-lubricating sealed ball bearings. It is designed to
provide durable service when
treated with ordinary care. We have a few suggestions to follow for the care
of your motor .
A . When the motor is operating, it cools itself internally by air entering
the rear of the motor case, provided proper clearance has been allowed.
B . Since the blower wheel is in the oven cavity it is at the same temperature
as the oven. If the motor is stopped while the oven is hot, the heat from the
blower wheel is
conducted down the shaft and into the armature of the motor. This action could
shorten motor life .
C . We recommend, at the end of the bake or roasting period, when the oven
will be idle for any period of time or before shutting down completely, that
the doors be left open, and by use of the cool-down position on the fan
switch, the fan continues to run for at least 20 minutes. The “FAN” should
never be turned “OFF” when the oven is “HOT” .
Hot Top Sections
- Raise or remove hot top plate section(s) . Each burner has one pilot located at the front left side of the burner.
- Light pilots. The pilot burner should be adjusted to provide for rapid ignition of the burner.
- Turn the burner valve on. A sharp blue flame should be approximately 1/4-inch, (6mm), high.
- Replace hot top sections .
Thermostat Controlled Griddles
See griddle seasoning before use.
-
For general thermostat griddle lighting instructions please refer to the section entitled “OVEN (STANDARD)” above. (Steps 2 through 7)
-
Pilots should be lit through the front panel with an extended match. If necessary the front panel of the range can be removed to allow the griddle plates to be raised at the
front, and block securely. -
Light pilots are located at the front left side of each burner
-
The sensing bulbs must be fully inserted into their individual holders, which are located on the underside of the griddle. To check the griddle burner flame set the thermostat to its maximum setting and then return to pilot.
-
If the griddle has been raised to light the pilots, lower carefully into position, being very careful not to leave any part of the capillary tube in the burner compartment . Replace the front panel of the range .
Valve Controlled Griddles
See griddle seasoning before use.
-
Pilots should be lit through the front panel with an extended match. If necessary the front panel of the range can be removed to allow the griddle plates to be raised at the
front, block securely . -
Light pilots are located at the front left side of each burner .
-
Turn burner valves completely on. Burners should have 1/2-inch to 5/8-inch, (13mm to 16mm), stable blue flame . 4 . If the griddle has been raised, lower it carefully into position and replace the front panel of the range.
Griddle/Broiler
(Models G60-6R24RR, G60-6R24SS, G60-6R24RS, G60-6R24CC, G60-6R24CR &
G60-6R24CS)
See griddle seasoning before use.
Before turning on the main gas supply, be sure all burner valves are in the
“OFF” position .
-
Eight (8) ceramic bricks are supplied with each range . These ceramics are to be placed in the burner section of the griddle/broiler before it is put into operation.
-
Each burner has a flange on each side which will serve as a rest for a pair of ceramics. Position two ceramics between each pair of burners with the projections facing
downward. Place two ceramics between the outside burner on each side, using the sidelining ledges as the outer support. -
Light the pilots located in the broiler section.
-
Turn the burner valves completely on. Burners should exhibit a 5/16-inch stable blue flame.
NOTE: If burners need adjustment contact an authorized licensed gas technician.
Range Shut down
- Turn all valves to the “OFF” position.
- If the unit is to be shut down for an extended period of time, close the in-line gas valve.
PRODUCT APPLICATION INFORMATION
General
The range is the workhorse of the kitchen because of its versatility. Most
frequently used in small applications, such as cafes, schools, church
kitchens, firehouses, and small nursing homes where demands are less taxing.
As a general rule of thumb, one four to the six-burner range with a hot top
will be adequate for a restaurant seating 30 to 35. The top of the range is
designed for flexibility and the preparation of numerous different types of
products. It may be equipped with two, or even three different types of tops
and burners, depending on the menu needs. An operation that cooks to order, or
uses the range primarily as a backup will find that open burners will suit
most of their needs.
Preparation of soups, stocks, or sauces is done on a hot top where slow, even
cooking is desirable .
Heating larger quantities of food can be done more efficiently than heating
small quantities. Pots and pans should be covered whenever possible to reduce
energy consumption
High-acid sauces, such as tomato should be cooked in stainless steel rather
than aluminum to avoid a chemical reaction. Light-colored sauces such as
Alfredo may be discolored by the use of aluminum, especially if stirred with a
metal spoon or whip. Saltwater shellfish may pit aluminum pots if they are
frequently used for this purpose.
NOTE: Many parts of the commercial range are raw steel. Hot tops, griddles,
springs, door hooks, etc ., can react with the moisture forming rust. This
occurrence is normal and not considered a defect. Clean with a stainless steel
or fiber pad . A light coating of cooking oil may be applied.
Open Burners
The most traditional uses of open burners are sautéing, pan frying, and small
stock pot work. Short-term cooking is the most efficient use for the open
burner. Pans should cover as much of the grate as possible to minimize heat
loss. The maximum stock pot size to be used on an open burner is 12 inches,
(305mm), in diameter. Open burners should be turned off when not in use to
conserve energy. Leaving a flame burning is of no advantage since the heat is
instantaneous.
MAINTENANCE AND CLEANING
Seasoning
Griddle
A . Remove all factory-applied protective material by washing with hot water,
mild detergent, or soap solution .
B . Apply a thin coat of cooking oil to the griddle surface, about one ounce
per square foot of the griddle surface . Spread over the entire griddle
surface with a cloth to create a thin film. Wipe off any excess oil with a
cloth .
C . Light all burners, and set at the lowest possible setting. Some
discoloration will occur when heat is applied to steel.
D . Heat the griddle slowly for 15 to 20 minutes. Then wipe away the oil.
Repeat the procedure 2 to 3 times until the griddle has a slick, mirror-like
finish. Do this until you have
reached the desired cooking temperature .
IMPORTANT: Do not set it to a high position (on valve control) or 450°
(on thermostat control) during the “break-in” period
NOTE: Steel griddle surface will tone (blue discoloration) from heat.
This toning will not diminish function or operation and it is not a defect.
The griddle will not require reseasoning if it is used properly . If the
griddle is overheated and the product begins to stick to the surface it may be
necessary to repeat the seasoning process again. If the griddle is cleaned
with soap and water it will be necessary to reseason the griddle surface .
Cast Iron top Grates
First, remove the cast iron top grates from the range. Wash the cast iron top
grates thoroughly with mild soap and warm water. Dry the cast-iron top grates
thoroughly with a clean cloth. Immediately after drying, season the top grates
lightly with a non-toxic oil, (Liquid vegetable oil or Pam spray oil) WARNING;
DO NOT SEASON THE TOP GRATES WHILE ON THE RANGE TOP! Seasoning grates on the
range top over an open flame could cause a flash fire. After seasoning,
replace the top grates with the range. Turn all the range top sections “ON
LOW”. Allow the top sections to burn in this manner for at least 20 minutes
before using pots or pans on the top grates. SEASONING OF THE TOP GRATES WILL
BE REQUIRED WHENEVER THEY HAVE BEEN CLEANED. FAILURE TO SEASON GRATES WILL
CAUSE RUSTING.
Stainless Steel
For routine cleaning, wash with hot water and a detergent solution . Wash just
a small area at a time or the water will evaporate leaving the chemicals
behind and causing streaking.
Rinse the washed area with a clean sponge dipped in a sanitizing solution and
wipe dry with a soft clean cloth before it can dry .
Use a paste (of water and a mild scouring powder) if you have to, but never
rub against the grain. All stainless steel has been polished in one direction
. Rub with the polish lines to preserve the original finish. Then thoroughly
rinse as before . To prevent fingerprints there are several stainless steel
polishes on the market that leave an oily or waxy film. Do not use on surfaces
that will be in contact with food . Stainless steel may discolor if
overheated. These stains can usually be removed by vigorous rubbing with a
scouring
powder paste .
Use only stainless steel, wood, or plastic tools if necessary to scrape off
heavy deposits of grease and oil. Do not use ordinary steel scrapers or
knives, as particles of the iron may become embedded and rust. NEVER USE STEEL
WOOL .
Either a typical bleach solution or hot water can be used to sanitize
stainless steel . Oven Interior (Porcelain Enamel) NOTE: Disconnect the line
cord (if applicable from the power supply before cleaning or servicing.
-
Before cleaning the oven interior, remove all oven racks and guides (if “RC” base) . Oven racks and guides can be cleaned with mild soap and warm water or run through
dishwasher. -
The porcelain interior can be cleaned with oven cleaners such as “Easy Off, or “Dow Oven Cleaner” .
Follow the product manufacturer’s instructions for proper use.
Open Top Burners
Cleaning of the range top burner is a simple procedure, and, if done at
regular intervals will prolong the life of the range and ensure good flame
characteristics.
-
The most common problem with open burner ranges is spillage. Once the burner ports are partially plugged with food, the air-to-gas mixture is disturbed and results in an
inefficient burner . -
Wipe any spills as they occur.
-
Grids and trays should be removed daily, washed, rinsed, and dried thoroughly.
-
Use a wire brush to clean the ports of the burners. Ignite and check for clogged holes .
-
If any clogged holes are apparent, the burner should be lifted out and brushed inside and out with a small Venturi brush. Each port on the burner itself should be cleaned with a properly sized wire or thumb drill. Wash with soap and hot water if grease is observed on the burners. Dry thoroughly.
-
When reinstalling the open top burner head be sure the burner ports are lined up correctly to the pilot. On the cast burner head, there is a raised indicator to ensure the burner is installed correctly .
-
If an abnormal flame appears around the edges, it is usually a sign of grease dirt in the throat of the burner . Remove the burner venturi (the main body that the burner heads sit on) to access the air shutter opening. Remove grease and dirt from the air shutter area carefully. Do not adjust the shutter setting. The air shutter allows the proper amount of air to mix with the flow of gas coming in from your valve/thermostat orifice and should not be adjusted unless by a licensed gas fitter technician..
Cast Iron Top & Grates
Cast iron top and grate(s) can be cleaned with mild soap and warm water. For
baked-on material, a wire brush can be used. Dry thoroughly. Lightly coat with
vegetable oil to help prevent rust from forming .
Hot Tops
While the surface is still slightly warm, wipe down with a clean burlap cloth.
Burnt spillage should be scraped off. If necessary, remove the plate and wash
in a sink with soap and hot water. Dry thoroughly. In damp climates, wipe down
with a light coating of oil to prevent rusting. Avoid excessive use of water
as this could damage the surface and the controls below.
NOTE: Steel griddle and hot top surface will “tone” (blue/ brown
discoloration) from heat. This toning will not diminish function or operation
and is not a defect.
Griddle
To produce evenly cooked, browned griddle products, keep the griddle free from
carbonized grease. Carbonized grease on the surface hinders the transfer of
heat from the griddle surface to food products. This results in uneven
browning and loss of cooking efficiency, and worst of all, carbonized grease
tends to cling to grilled foods, giving them a highly unsatisfactory and
unappetizing appearance. To keep the griddle clean and operating at peak
performance, follow these simple instructions:
A . AFTER EACH USE clean griddle thoroughly with a grill scraper or spatula.
Wipe off any excess debris left from the cooking process.
B . ONCE A DAY clean the griddle surface with a grill brick and grill pad.
Remove the grease container and clean thoroughly, in the same manner as any
ordinary cooking utensil.
C . ONCE A WEEK clean the griddle surface thoroughly. If necessary, use a
grill stone or grill pad over the griddle surface. Rub with the grain of the
metal while still warm. A detergent may be used on the plate surface to help
clean it, but care must be taken to be sure it is thoroughly removed. After
the removal of detergent, the surface of the plate should be covered with a
thin film of oil to prevent rusting. To remove discolorations, use a non-
abrasive cleaner. Before re-using, the griddle must be reseasoned .
Keep griddle drain tube to grease container clear at all times.
CAUTION This griddle plate is steel, but the surface is relatively soft and
can be scored or dented by careless use of a spatula.
Be careful not to dent, scratch, or gouge the plate surface . This will cause
food to stick in those areas. Also, note, since this is a steel griddle if a
light coating of oil is not always
present rust will develop on exposed and uncoated areas.
APPENDIX
Wiring Diagrams
NOTE:
Wiring Diagrams are also attached to the back of the range.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>